ivive.app is an MCP server published by app.ivive, hosted at api.ivive.app. When last checked on 2026-11-24 it was working: it answers and lists its tools. It declares 6 tools, including predict_inputs, calc_clhep, target_clint, input_sensitivity, similar_drugs.
Human hepatic clearance from in-vitro CLint, with the error band measured on known drugs.
1 connections through 4 shared values. Tap any node.
Inferred from the host name and headers: what a server runs on, not who runs it.
Predict fu,p and fu,inc from a SMILES, with structure-only human CL and Vss as second opinions. Predictions, not measurements; check the applicability verdict.
| Parameter | Type | Description |
|---|---|---|
| smiles * | string | Structure as SMILES. |
| assay_type | string | Incubation fu,inc is predicted for: microsomes or hepatocytes. |
| concentration | number | Incubation concentration: mg microsomal protein/mL, or 10⁶ hepatocytes/mL. |
{
"name": "predict_inputs",
"description": "Predict fu,p and fu,inc from a SMILES, with structure-only human CL and Vss as second opinions. Predictions, not measurements; check the applicability verdict.",
"inputSchema": {
"type": "object",
"title": "PredictionRequest",
"required": [
"smiles"
],
"properties": {
"smiles": {
"type": "string",
"title": "Smiles",
"maxLength": 2000,
"description": "Structure as SMILES."
},
"assay_type": {
"enum": [
"microsomes",
"hepatocytes"
],
"type": "string",
"title": "Assay Type",
"default": "microsomes",
"description": "Incubation fu,inc is predicted for: microsomes or hepatocytes."
},
"concentration": {
"type": "number",
"title": "Concentration",
"default": 1,
"maximum": 10,
"description": "Incubation concentration: mg microsomal protein/mL, or 10⁶ hepatocytes/mL.",
"exclusiveMinimum": 0
}
}
},
"annotations": {
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}None yet. Changes appear after a server's second daily check.
Squares are this server's values; dots are other servers sharing them. A shared address or publisher is a lead, not proof of a common operator.
Hepatic and plasma clearance from in-vitro CLint, fu,mic and fu,p (IVIVE), with the observed-CL band and applicability warnings. If fu,p or fu,mic came from predict_inputs, tell the user the result rests on predicted inputs.
| Parameter | Type | Description |
|---|---|---|
| rb | number | Blood-to-plasma concentration ratio. fu_b = fu_p / Rb. Output is blood clearance. |
| fu_p * | number | Unbound fraction in plasma (0–1). Plasma protein binding correction. |
| clint * | number | Intrinsic clearance (µL/min/mg microsomal protein). Use ge=0: zero clearance is physiologically valid. |
| model | string | IVIVE model. well-stirred (venous equilibrium) or parallel-tube (sinusoidal perfusion). |
| fu_mic * | number | Unbound fraction in microsomes (0–1). Corrects for non-specific microsomal binding. |
| species * | string | Species for physiological parameters (Qh, MPPGL, liver weight). |
| assay_type | string | Assay type for CLint scaling. microsomes: uses MPPGL (mg/g) × 1e-3; hepatocytes: uses HPGL (×10⁶ cells/g) × 1e-3. |
| correction_id | any | Saved lab correction (/api/correction-equations) to apply. Must match species and assay_type. Corrects predicted plasma CL and replaces the reference band with one from the lab's compounds. |
| clint_censored | boolean | Set when the assay reported CLint below its limit of quantification and `clint` is that limit rather than a measurement. CLint then lies in [0, clint), so every clearance output is an upper bound: `upper_bound` is true, no observed-CL band is returned, and the clint_below_loq flag fires. |
{
"name": "calc_clhep",
"description": "Hepatic and plasma clearance from in-vitro CLint, fu,mic and fu,p (IVIVE), with the observed-CL band and applicability warnings. If fu,p or fu,mic came from predict_inputs, tell the user the result rests on predicted inputs.",
"inputSchema": {
"type": "object",
"title": "CLhepRequest",
"required": [
"clint",
"fu_mic",
"fu_p",
"species"
],
"properties": {
"rb": {
"type": "number",
"title": "Rb",
"default": 1,
"maximum": 50,
"description": "Blood-to-plasma concentration ratio. fu_b = fu_p / Rb. Output is blood clearance.",
"exclusiveMinimum": 0
},
"fu_p": {
"type": "number",
"title": "Fu P",
"maximum": 1,
"minimum": 0,
"description": "Unbound fraction in plasma (0–1). Plasma protein binding correction."
},
"clint": {
"type": "number",
"title": "Clint",
"minimum": 0,
"description": "Intrinsic clearance (µL/min/mg microsomal protein). Use ge=0: zero clearance is physiologically valid."
},
"model": {
"enum": [
"well-stirred",
"parallel-tube"
],
"type": "string",
"title": "Model",
"default": "well-stirred",
"description": "IVIVE model. well-stirred (venous equilibrium) or parallel-tube (sinusoidal perfusion)."
},
"fu_mic": {
"type": "number",
"title": "Fu Mic",
"maximum": 1,
"description": "Unbound fraction in microsomes (0–1). Corrects for non-specific microsomal binding.",
"exclusiveMinimum": 0
},
"species": {
"enum": [
"human",
"rat",
"dog"
],
"type": "string",
"title": "Species",
"description": "Species for physiological parameters (Qh, MPPGL, liver weight)."
},
"assay_type": {
"enum": [
"microsomes",
"hepatocytes"
],
"type": "string",
"title": "Assay Type",
"default": "microsomes",
"description": "Assay type for CLint scaling. microsomes: uses MPPGL (mg/g) × 1e-3; hepatocytes: uses HPGL (×10⁶ cells/g) × 1e-3."
},
"correction_id": {
"anyOf": [
{
"type": "string",
"format": "uuid"
},
{
"type": "null"
}
],
"title": "Correction Id",
"default": null,
"description": "Saved lab correction (/api/correction-equations) to apply. Must match species and assay_type. Corrects predicted plasma CL and replaces the reference band with one from the lab's compounds."
},
"clint_censored": {
"type": "boolean",
"title": "Clint Censored",
"default": false,
"description": "Set when the assay reported CLint below its limit of quantification and `clint` is that limit rather than a measurement. CLint then lies in [0, clint), so every clearance output is an upper bound: `upper_bound` is true, no observed-CL band is returned, and the clint_below_loq flag fires."
}
}
},
"annotations": {
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}The in-vitro CLint an assay must read for a compound to reach a target plasma clearance (mL/min/kg): calc_clhep run backwards, e.g. to set a CLint cut-off for a screening cascade. Needs fu,mic and fu,p; refuses a target at or above the liver blood flow ceiling and returns that ceiling. Uncorrected IVIVE, so no error band.
| Parameter | Type | Description |
|---|---|---|
| rb | number | Blood-to-plasma concentration ratio; raises the plasma CL ceiling (Qh × Rb). |
| fu_p * | number | Unbound fraction in plasma (0–1). |
| model | string | IVIVE liver model to invert. |
| fu_mic * | number | Unbound fraction in the incubation (0–1) the CLint would be measured at. |
| species * | string | Species whose liver blood flow and scaling factors apply. |
| assay_type | string | Assay the CLint is for; sets its units (µL/min/mg protein or µL/min/10⁶ cells). |
| target_clp * | number | Plasma clearance to aim for (mL/min/kg). Must be below hepatic blood flow × Rb. |
{
"name": "target_clint",
"description": "The in-vitro CLint an assay must read for a compound to reach a target plasma clearance (mL/min/kg): calc_clhep run backwards, e.g. to set a CLint cut-off for a screening cascade. Needs fu,mic and fu,p; refuses a target at or above the liver blood flow ceiling and returns that ceiling. Uncorrected IVIVE, so no error band.",
"inputSchema": {
"type": "object",
"title": "TargetClintRequest",
"required": [
"target_clp",
"fu_mic",
"fu_p",
"species"
],
"properties": {
"rb": {
"type": "number",
"title": "Rb",
"default": 1,
"maximum": 50,
"description": "Blood-to-plasma concentration ratio; raises the plasma CL ceiling (Qh × Rb).",
"exclusiveMinimum": 0
},
"fu_p": {
"type": "number",
"title": "Fu P",
"maximum": 1,
"description": "Unbound fraction in plasma (0–1).",
"exclusiveMinimum": 0
},
"model": {
"enum": [
"well-stirred",
"parallel-tube"
],
"type": "string",
"title": "Model",
"default": "well-stirred",
"description": "IVIVE liver model to invert."
},
"fu_mic": {
"type": "number",
"title": "Fu Mic",
"maximum": 1,
"description": "Unbound fraction in the incubation (0–1) the CLint would be measured at.",
"exclusiveMinimum": 0
},
"species": {
"enum": [
"human",
"rat",
"dog"
],
"type": "string",
"title": "Species",
"description": "Species whose liver blood flow and scaling factors apply."
},
"assay_type": {
"enum": [
"microsomes",
"hepatocytes"
],
"type": "string",
"title": "Assay Type",
"default": "microsomes",
"description": "Assay the CLint is for; sets its units (µL/min/mg protein or µL/min/10⁶ cells)."
},
"target_clp": {
"type": "number",
"title": "Target Clp",
"description": "Plasma clearance to aim for (mL/min/kg). Must be below hepatic blood flow × Rb.",
"exclusiveMinimum": 0
}
}
},
"annotations": {
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}How far plasma CL moves as each input is varied over a range, e.g. a predicted fu,p over its 50% range.
| Parameter | Type | Description |
|---|---|---|
| rb | number | Blood-to-plasma concentration ratio. fu_b = fu_p / Rb. Output is blood clearance. |
| fu_p * | number | Unbound fraction in plasma (0–1). Plasma protein binding correction. |
| clint * | number | Intrinsic clearance (µL/min/mg microsomal protein). Use ge=0: zero clearance is physiologically valid. |
| model | string | IVIVE model. well-stirred (venous equilibrium) or parallel-tube (sinusoidal perfusion). |
| fu_mic * | number | Unbound fraction in microsomes (0–1). Corrects for non-specific microsomal binding. |
| species * | string | Species for physiological parameters (Qh, MPPGL, liver weight). |
| assay_type | string | Assay type for CLint scaling. microsomes: uses MPPGL (mg/g) × 1e-3; hepatocytes: uses HPGL (×10⁶ cells/g) × 1e-3. |
| fu_p_range | any | A predicted fu,p carries its 50% range; pass it to see what it costs. |
| clint_range | any | CLint range in the assay's units, e.g. {"low": 10, "high": 40}. |
| fu_mic_range | any | fu,mic range (0–1), e.g. {"low": 0.5, "high": 0.9}. |
| correction_id | any | Saved lab correction (/api/correction-equations) to apply. Must match species and assay_type. Corrects predicted plasma CL and replaces the reference band with one from the lab's compounds. |
| clint_censored | boolean | Set when the assay reported CLint below its limit of quantification and `clint` is that limit rather than a measurement. CLint then lies in [0, clint), so every clearance output is an upper bound: `upper_bound` is true, no observed-CL band is returned, and the clint_below_loq flag fires. |
{
"name": "input_sensitivity",
"description": "How far plasma CL moves as each input is varied over a range, e.g. a predicted fu,p over its 50% range.",
"inputSchema": {
"type": "object",
"$defs": {
"InputRange": {
"type": "object",
"title": "InputRange",
"required": [
"low",
"high"
],
"properties": {
"low": {
"type": "number",
"title": "Low",
"description": "Low end, in the input's own units, e.g. 0.05 for fu,p.",
"exclusiveMinimum": 0
},
"high": {
"type": "number",
"title": "High",
"description": "High end, in the input's own units, e.g. 0.2 for fu,p.",
"exclusiveMinimum": 0
}
}
}
},
"title": "SensitivityRequest",
"required": [
"clint",
"fu_mic",
"fu_p",
"species"
],
"properties": {
"rb": {
"type": "number",
"title": "Rb",
"default": 1,
"maximum": 50,
"description": "Blood-to-plasma concentration ratio. fu_b = fu_p / Rb. Output is blood clearance.",
"exclusiveMinimum": 0
},
"fu_p": {
"type": "number",
"title": "Fu P",
"maximum": 1,
"minimum": 0,
"description": "Unbound fraction in plasma (0–1). Plasma protein binding correction."
},
"clint": {
"type": "number",
"title": "Clint",
"minimum": 0,
"description": "Intrinsic clearance (µL/min/mg microsomal protein). Use ge=0: zero clearance is physiologically valid."
},
"model": {
"enum": [
"well-stirred",
"parallel-tube"
],
"type": "string",
"title": "Model",
"default": "well-stirred",
"description": "IVIVE model. well-stirred (venous equilibrium) or parallel-tube (sinusoidal perfusion)."
},
"fu_mic": {
"type": "number",
"title": "Fu Mic",
"maximum": 1,
"description": "Unbound fraction in microsomes (0–1). Corrects for non-specific microsomal binding.",
"exclusiveMinimum": 0
},
"species": {
"enum": [
"human",
"rat",
"dog"
],
"type": "string",
"title": "Species",
"description": "Species for physiological parameters (Qh, MPPGL, liver weight)."
},
"assay_type": {
"enum": [
"microsomes",
"hepatocytes"
],
"type": "string",
"title": "Assay Type",
"default": "microsomes",
"description": "Assay type for CLint scaling. microsomes: uses MPPGL (mg/g) × 1e-3; hepatocytes: uses HPGL (×10⁶ cells/g) × 1e-3."
},
"fu_p_range": {
"anyOf": [
{
"$ref": "#/$defs/InputRange"
},
{
"type": "null"
}
],
"default": null,
"description": "A predicted fu,p carries its 50% range; pass it to see what it costs."
},
"clint_range": {
"anyOf": [
{
"$ref": "#/$defs/InputRange"
},
{
"type": "null"
}
],
"default": null,
"description": "CLint range in the assay's units, e.g. {\"low\": 10, \"high\": 40}."
},
"fu_mic_range": {
"anyOf": [
{
"$ref": "#/$defs/InputRange"
},
{
"type": "null"
}
],
"default": null,
"description": "fu,mic range (0–1), e.g. {\"low\": 0.5, \"high\": 0.9}."
},
"correction_id": {
"anyOf": [
{
"type": "string",
"format": "uuid"
},
{
"type": "null"
}
],
"title": "Correction Id",
"default": null,
"description": "Saved lab correction (/api/correction-equations) to apply. Must match species and assay_type. Corrects predicted plasma CL and replaces the reference band with one from the lab's compounds."
},
"clint_censored": {
"type": "boolean",
"title": "Clint Censored",
"default": false,
"description": "Set when the assay reported CLint below its limit of quantification and `clint` is that limit rather than a measurement. CLint then lies in [0, clint), so every clearance output is an upper bound: `upper_bound` is true, no observed-CL band is returned, and the clint_below_loq flag fires."
}
},
"description": "The same inputs as a calculation, plus the range to vary each over."
},
"annotations": {
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Nearest reference drugs to a SMILES (Tanimoto, Morgan radius 2), each with measured human plasma CL and the CL IVIVE predicted from its measured inputs. Use it to judge how far to trust calc_clhep for this chemotype: if IVIVE missed on the neighbours, expect it to miss here. Returns neighbours only, not a prediction for the query.
| Parameter | Type | Description |
|---|---|---|
| n | integer | How many reference drugs to return, nearest first. |
| smiles * | string | Structure as SMILES. |
{
"name": "similar_drugs",
"description": "Nearest reference drugs to a SMILES (Tanimoto, Morgan radius 2), each with measured human plasma CL and the CL IVIVE predicted from its measured inputs. Use it to judge how far to trust calc_clhep for this chemotype: if IVIVE missed on the neighbours, expect it to miss here. Returns neighbours only, not a prediction for the query.",
"inputSchema": {
"type": "object",
"title": "SimilarityRequest",
"required": [
"smiles"
],
"properties": {
"n": {
"type": "integer",
"title": "N",
"default": 3,
"maximum": 10,
"minimum": 1,
"description": "How many reference drugs to return, nearest first."
},
"smiles": {
"type": "string",
"title": "Smiles",
"maxLength": 2000,
"description": "Structure as SMILES."
}
}
},
"annotations": {
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Predict human plasma CL from observed animal in-vivo CL (rat, dog, monkey), every applicable method with its measured error. Observed animal CL only, never predicted.
| Parameter | Type | Description |
|---|---|---|
| animals * | array | One entry per species, e.g. [{"species": "rat", "cl": 40}, {"species": "dog", "cl": 12}]. |
| fu_p_human | any | Human unbound fraction, needed by the fu-corrected methods |
{
"name": "scale_to_human",
"description": "Predict human plasma CL from observed animal in-vivo CL (rat, dog, monkey), every applicable method with its measured error. Observed animal CL only, never predicted.",
"inputSchema": {
"type": "object",
"$defs": {
"SpeciesPoint": {
"type": "object",
"title": "SpeciesPoint",
"required": [
"species",
"cl"
],
"properties": {
"cl": {
"type": "number",
"title": "Cl",
"maximum": 1000,
"description": "Observed plasma CL, mL/min/kg",
"exclusiveMinimum": 0
},
"fu_p": {
"anyOf": [
{
"type": "number",
"maximum": 1,
"exclusiveMinimum": 0
},
{
"type": "null"
}
],
"title": "Fu P",
"default": null,
"description": "Unbound fraction in plasma for this species"
},
"species": {
"type": "string",
"title": "Species",
"description": "One of ['dog', 'monkey', 'rat']"
}
},
"description": "One animal's measured in-vivo plasma clearance, and optionally its binding."
}
},
"title": "ScalingRequest",
"required": [
"animals"
],
"properties": {
"animals": {
"type": "array",
"items": {
"$ref": "#/$defs/SpeciesPoint"
},
"title": "Animals",
"minItems": 1,
"description": "One entry per species, e.g. [{\"species\": \"rat\", \"cl\": 40}, {\"species\": \"dog\", \"cl\": 12}]."
},
"fu_p_human": {
"anyOf": [
{
"type": "number",
"maximum": 1,
"exclusiveMinimum": 0
},
{
"type": "null"
}
],
"title": "Fu P Human",
"default": null,
"description": "Human unbound fraction, needed by the fu-corrected methods"
}
}
},
"annotations": {
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}ADME/IVIVE calculations for early drug discovery. Do not compute clearance yourself: call these tools. Relay the warnings and caveats in each result to the user. Values from predict_inputs are predictions; when they feed another tool, say so. All results are research estimates, not for clinical, regulatory or dosing decisions; tell the user so.
Names, descriptions and schemas were written by the server and are shown as data.