Ampworth calculators is an MCP server published by com.ampworth, hosted at ampworth.com. When last checked on 2026-11-23 it was working: it answers and lists its tools. It declares 12 tools, including connection_route, heat_pump_noise, heat_pump_running_cost, heat_pump_size, hot_water_cylinder.
UK solar PV and heat pump calculators that follow the published MCS methods. Open, no key.
205 connections through 4 shared values. Tap any node.
Inferred from the host name and headers: what a server runs on, not who runs it.
Work out which ENA connection procedure a domestic installation of solar panels, batteries or both falls under: connect first and notify the distribution network operator within 28 days, or apply and wait for approval before anything is connected. The rules are the ENA's engineering recommendations, not MCS documents: EREC G98 for small installations, EREC G99 for everything larger, and EREC G100 for export limitation. Every test is in amps per phase at a nominal 230 V, and it applies to the premises as a whole, so list EVERY inverter that can export, existing ones included. A battery counts as generation even if it only ever charges from the panels. The figure that counts is each inverter's registered capacity: its AC rating, or a lower limit the manufacturer has fixed. It is NOT the panels' kWp. A 4.4 kWp array on a 3.68 kW inverter is a 3.68 kW installation. Where an inverter has been capped below its hardware rating, give the hardware rating as 'designCapacityKw', because G99 tests that separately. The routes are: G98 when the total is 16 A per phase or less (3.68 kW single phase, 11.04 kW three phase); G99 SGI-1, also connect and notify, when the total is within 16 A but an inverter built for up to 32 A has been capped; G99 SGI-2 and SGI-3, fast track applications answered within 10 working days, which allow larger totals held back by a type-tested export limiter; and the standard G99 application for anything else. An export limiter NEVER brings an installation under G98. IMPORTANT: this says which procedure applies, not what the operator will decide. Approval depends on the local network, which only the operator can assess. Say so whenever you report a result. Method from EREC G98 / G99. These calculators follow the published MCS methods, for understanding a system and checking a quotation. Anything that gets installed still needs a design and a site survey from a certified installer.
None yet. Changes appear after a server's second daily check.
Squares are this server's values; dots are other servers sharing them. A shared address or publisher is a lead, not proof of a common operator.
| Parameter | Type | Description |
|---|---|---|
| phases | integer | The supply: 1 for single phase, which is almost every British house, or 3 for three phase. Defaults to 1. |
| devices * | ["null","array"] | Every inverter at the premises that can export: solar, battery and hybrid, existing ones included. A battery counts even if it only charges from the panels. At least one is required. |
| exportLimitKw | number | The export limit a fully type-tested G100 scheme would hold the premises to, in kW per phase, where one is proposed. Optional. An export limit never brings an installation under G98, but it decides which G99 route applies. |
| otherInstallationsNearby | boolean | True when the same installer has fitted, or plans to fit, generation at other premises within 500 metres, or on the same street, within 28 days either side. That turns a G98 notification into an application. Defaults to false. |
{
"name": "connection_route",
"title": "Network connection route",
"description": "Work out which ENA connection procedure a domestic installation of solar panels,\nbatteries or both falls under: connect first and notify the distribution network operator within 28\ndays, or apply and wait for approval before anything is connected.\n\nThe rules are the ENA's engineering recommendations, not MCS documents: EREC G98 for small\ninstallations, EREC G99 for everything larger, and EREC G100 for export limitation. Every test is in\namps per phase at a nominal 230 V, and it applies to the premises as a whole, so list EVERY inverter\nthat can export, existing ones included. A battery counts as generation even if it only ever charges\nfrom the panels.\n\nThe figure that counts is each inverter's registered capacity: its AC rating, or a lower limit the\nmanufacturer has fixed. It is NOT the panels' kWp. A 4.4 kWp array on a 3.68 kW inverter is a 3.68 kW\ninstallation. Where an inverter has been capped below its hardware rating, give the hardware rating as\n'designCapacityKw', because G99 tests that separately.\n\nThe routes are: G98 when the total is 16 A per phase or less (3.68 kW single phase, 11.04 kW three\nphase); G99 SGI-1, also connect and notify, when the total is within 16 A but an inverter built for up\nto 32 A has been capped; G99 SGI-2 and SGI-3, fast track applications answered within 10 working days,\nwhich allow larger totals held back by a type-tested export limiter; and the standard G99 application\nfor anything else. An export limiter NEVER brings an installation under G98.\n\nIMPORTANT: this says which procedure applies, not what the operator will decide. Approval depends on\nthe local network, which only the operator can assess. Say so whenever you report a result.\n\nMethod from EREC G98 / G99. These calculators follow the published MCS methods, for understanding a system and checking a quotation. Anything that gets installed still needs a design and a site survey from a certified installer.",
"inputSchema": {
"type": "object",
"required": [
"devices"
],
"properties": {
"phases": {
"type": "integer",
"description": "The supply: 1 for single phase, which is almost every British house, or 3 for three phase. Defaults to 1."
},
"devices": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"kind",
"registeredCapacityKw"
],
"properties": {
"kind": {
"type": "string",
"description": "'solar' for a solar inverter, 'battery' for an AC-coupled battery inverter, 'hybrid' for one inverter serving both panels and battery, or 'other'. Required."
},
"label": {
"type": "string",
"description": "A name for this device, for the breakdown."
},
"phase": {
"type": "string",
"description": "On a three phase supply, which phase the device is connected to: 'L1', 'L2', 'L3', or 'all' for a three phase inverter, which is split evenly. Ignored on a single phase supply. Defaults to 'L1'."
},
"existing": {
"type": "boolean",
"description": "True for a device that is already installed. It still counts toward the total. Defaults to false."
},
"designCapacityKw": {
"type": "number",
"description": "What the inverter was built to deliver before any fixed limit, in kW AC: G99 calls this the intrinsic design capacity. Only differs from 'registeredCapacityKw' for an inverter capped below its hardware rating. Defaults to the registered capacity."
},
"registeredCapacityKw": {
"type": "number",
"description": "The most the device can export, in kW AC: the inverter's rated output, or a lower limit the manufacturer has fixed so the customer cannot change it. From the datasheet or the ENA type test register. Not the panels' kWp. Required."
}
},
"additionalProperties": false
},
"description": "Every inverter at the premises that can export: solar, battery and hybrid, existing ones included. A battery counts even if it only charges from the panels. At least one is required."
},
"exportLimitKw": {
"type": "number",
"description": "The export limit a fully type-tested G100 scheme would hold the premises to, in kW per phase, where one is proposed. Optional. An export limit never brings an installation under G98, but it decides which G99 route applies."
},
"otherInstallationsNearby": {
"type": "boolean",
"description": "True when the same installer has fitted, or plans to fit, generation at other premises within 500 metres, or on the same street, within 28 days either side. That turns a G98 notification into an application. Defaults to false."
}
},
"additionalProperties": false
},
"outputSchema": {
"type": "object",
"required": [
"route",
"devices",
"phases",
"totalKw",
"worstPhaseA",
"g98LimitKw",
"verdict",
"warning",
"method",
"references",
"notes"
],
"properties": {
"notes": {
"type": [
"null",
"array"
],
"items": {
"type": "string"
}
},
"route": {
"type": "object",
"required": [
"key",
"label",
"applyFirst",
"notifyWithinDays",
"form",
"document"
],
"properties": {
"key": {
"type": "string",
"description": "'g98', 'g98_multiple_premises', 'g99_sgi_1', 'g99_sgi_2', 'g99_sgi_3' or 'g99_standard'."
},
"form": {
"type": "string",
"description": "The ENA form the installer submits, unless it goes through Connect Direct."
},
"label": {
"type": "string"
},
"document": {
"type": "string",
"description": "The engineering recommendation and section that sets the route."
},
"applyFirst": {
"type": "boolean",
"description": "True when the operator must approve before connection; false when the installer connects first and notifies afterwards."
},
"notifyWithinDays": {
"type": "integer",
"description": "Days after commissioning by which the installer must tell the operator, or confirm commissioning. 28 on every route."
},
"responseWorkingDays": {
"type": "integer",
"description": "Working days the operator has to respond to an application: 10 on the small generation routes, 45 for a quotation on the standard one. Absent for a notification."
}
},
"additionalProperties": false
},
"method": {
"type": "string"
},
"phases": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"phase",
"kw",
"currentA"
],
"properties": {
"kw": {
"type": "number"
},
"phase": {
"type": "string"
},
"currentA": {
"type": "number"
}
},
"additionalProperties": false
},
"description": "Registered capacity on each phase, in kW and in amps at the nominal 230 V the recommendations use."
},
"devices": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"label",
"kind",
"phase",
"existing",
"registeredCapacityKw",
"designCapacityKw",
"registeredCurrentA",
"designCurrentA"
],
"properties": {
"kind": {
"type": "string"
},
"label": {
"type": "string"
},
"phase": {
"type": "string"
},
"existing": {
"type": "boolean"
},
"designCurrentA": {
"type": "number",
"description": "Intrinsic design capacity per phase, in amps at 230 V."
},
"designCapacityKw": {
"type": "number"
},
"registeredCurrentA": {
"type": "number",
"description": "Registered capacity per phase, in amps at 230 V."
},
"registeredCapacityKw": {
"type": "number"
}
},
"additionalProperties": false
}
},
"totalKw": {
"type": "number",
"description": "Registered capacity of every device added together."
},
"verdict": {
"type": "string"
},
"warning": {
"type": "string",
"description": "Which route applies is arithmetic; what the network operator decides is not. Always present."
},
"g98LimitKw": {
"type": "number",
"description": "16 A per phase at 230 V: 3.68 kW on a single phase supply, 11.04 kW on three phase."
},
"references": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"document",
"title",
"url"
],
"properties": {
"url": {
"type": "string"
},
"title": {
"type": "string"
},
"clause": {
"type": "string"
},
"document": {
"type": "string"
}
},
"additionalProperties": false
}
},
"worstPhaseA": {
"type": "number",
"description": "Current on the most heavily loaded phase. This is the figure the thresholds are tested against."
},
"alternatives": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"change",
"route",
"cost"
],
"properties": {
"cost": {
"type": "string",
"description": "What the change gives up, in words."
},
"route": {
"type": "object",
"required": [
"key",
"label",
"applyFirst",
"notifyWithinDays",
"form",
"document"
],
"properties": {
"key": {
"type": "string",
"description": "'g98', 'g98_multiple_premises', 'g99_sgi_1', 'g99_sgi_2', 'g99_sgi_3' or 'g99_standard'."
},
"form": {
"type": "string",
"description": "The ENA form the installer submits, unless it goes through Connect Direct."
},
"label": {
"type": "string"
},
"document": {
"type": "string",
"description": "The engineering recommendation and section that sets the route."
},
"applyFirst": {
"type": "boolean",
"description": "True when the operator must approve before connection; false when the installer connects first and notifies afterwards."
},
"notifyWithinDays": {
"type": "integer",
"description": "Days after commissioning by which the installer must tell the operator, or confirm commissioning. 28 on every route."
},
"responseWorkingDays": {
"type": "integer",
"description": "Working days the operator has to respond to an application: 10 on the small generation routes, 45 for a quotation on the standard one. Absent for a notification."
}
},
"additionalProperties": false
},
"change": {
"type": "string"
}
},
"additionalProperties": false
},
"description": "Changes that would put the installation on an easier route, and what each would cost."
},
"exportLimitA": {
"type": "number",
"description": "The proposed export limit converted to amps per phase."
}
},
"additionalProperties": false
},
"annotations": {
"title": "Network connection route",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Calculate the sound pressure level an air source heat pump produces at an assessment position, and whether it meets the 37 dB(A) permitted development noise limit, using the method in MCS 020. The formula is Lp = Lw + 10 log(Q / 4.pi.r^2) - Ab. Lw is the A-weighted sound POWER level of the unit from its product fiche, energy label or the MCS product database. This is not the sound pressure level, which is a smaller number that already has a distance built into it; confusing the two produces an answer that is wrong by about twenty decibels. The figure for low noise mode must not be used. Q is the directivity factor, from the count of reflecting surfaces within one metre of the unit that extend at least a metre past it in two or more directions. The ground counts; vegetation does not. One surface gives Q=2, two gives Q=4, three gives Q=8. More than three cannot meet MCS 020 at all. r is the straight-line distance in metres to the assessment position, which is a window or door of a habitable room in a NEIGHBOURING property, at any floor. Every affected position must be checked separately, and the nearest is not always the worst. Ab is the barrier attenuation. Fences with gaps, and vegetation of any kind, count as no barrier. Where several units serve one position, list them all and they are combined logarithmically. Method from MCS 020. These calculators follow the published MCS methods, for understanding a system and checking a quotation. Anything that gets installed still needs a design and a site survey from a certified installer.
| Parameter | Type | Description |
|---|---|---|
| units * | ["null","array"] | The heat pump or heat pumps being assessed, each with its own distance and barrier to this assessment position. At least one is required. |
{
"name": "heat_pump_noise",
"title": "Heat pump noise assessment",
"description": "Calculate the sound pressure level an air source heat pump produces at an assessment\nposition, and whether it meets the 37 dB(A) permitted development noise limit, using the method in\nMCS 020.\n\nThe formula is Lp = Lw + 10 log(Q / 4.pi.r^2) - Ab.\n\nLw is the A-weighted sound POWER level of the unit from its product fiche, energy label or the MCS\nproduct database. This is not the sound pressure level, which is a smaller number that already has a\ndistance built into it; confusing the two produces an answer that is wrong by about twenty decibels.\nThe figure for low noise mode must not be used.\n\nQ is the directivity factor, from the count of reflecting surfaces within one metre of the unit that\nextend at least a metre past it in two or more directions. The ground counts; vegetation does not.\nOne surface gives Q=2, two gives Q=4, three gives Q=8. More than three cannot meet MCS 020 at all.\n\nr is the straight-line distance in metres to the assessment position, which is a window or door of a\nhabitable room in a NEIGHBOURING property, at any floor. Every affected position must be checked\nseparately, and the nearest is not always the worst.\n\nAb is the barrier attenuation. Fences with gaps, and vegetation of any kind, count as no barrier.\n\nWhere several units serve one position, list them all and they are combined logarithmically.\n\nMethod from MCS 020. These calculators follow the published MCS methods, for understanding a system and checking a quotation. Anything that gets installed still needs a design and a site survey from a certified installer.",
"inputSchema": {
"type": "object",
"required": [
"units"
],
"properties": {
"units": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"soundPowerLevel",
"distance",
"reflectingSurfaces"
],
"properties": {
"label": {
"type": "string",
"description": "A name for this unit, for a result covering more than one."
},
"distance": {
"type": "number",
"description": "Straight-line distance in metres from the centre of the unit to the assessment position, measured to the nearest 0.1 m. Required."
},
"barrierType": {
"type": "string",
"description": "'type_1' for solid masonry or a solid fence at least 18 mm thick, 'type_2' for a solid fence thinner than 18 mm, or 'none'. Fences with gaps, and vegetation, are 'none'. Defaults to 'none'."
},
"lineOfSight": {
"type": "string",
"description": "Whether the assessment position can be seen from the top edge of the unit: 'none', 'partial' (visible if you move up to 0.25 m in any direction) or 'full'. Defaults to 'full'."
},
"soundPowerLevel": {
"type": "number",
"description": "A-weighted sound POWER level of the unit in dB(A), from the product fiche, the energy label or the MCS product database. Not the sound pressure level, which is a different and smaller number. The figure for low noise mode must not be used. Required."
},
"reflectingSurfaces": {
"type": "integer",
"description": "How many surfaces sit within one metre of the unit and extend at least a metre past it in two or more directions. The ground counts; vegetation does not. 1, 2 or 3. More than 3 fails MCS 020 outright. Required."
}
},
"additionalProperties": false
},
"description": "The heat pump or heat pumps being assessed, each with its own distance and barrier to this assessment position. At least one is required."
}
},
"additionalProperties": false
},
"outputSchema": {
"type": "object",
"required": [
"units",
"soundPressureLevel",
"limit",
"compliant",
"headroom",
"verdict",
"method",
"references",
"notes"
],
"properties": {
"limit": {
"type": "number",
"description": "The permitted development noise limit, 37.0 dB(A)."
},
"notes": {
"type": [
"null",
"array"
],
"items": {
"type": "string"
}
},
"units": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"soundPowerLevel",
"distance",
"directivity",
"barrierAttenuation",
"soundPressureLevel",
"distanceLoss"
],
"properties": {
"label": {
"type": "string"
},
"distance": {
"type": "number"
},
"directivity": {
"type": "integer",
"description": "Q: 2 for one reflecting surface, 4 for two, 8 for three."
},
"distanceLoss": {
"type": "number",
"description": "Decibels lost to spreading out over the distance."
},
"soundPowerLevel": {
"type": "number"
},
"barrierAttenuation": {
"type": "number",
"description": "Decibels the barrier takes off, from the MCS 020 matrix."
},
"soundPressureLevel": {
"type": "number"
}
},
"additionalProperties": false
}
},
"method": {
"type": "string"
},
"verdict": {
"type": "string"
},
"headroom": {
"type": "number",
"description": "Decibels below the limit. Negative when the limit is exceeded."
},
"remedies": {
"type": [
"null",
"array"
],
"items": {
"type": "string"
},
"description": "What would bring a failing position within the limit."
},
"compliant": {
"type": "boolean",
"description": "True when the level is at or below the limit."
},
"references": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"document",
"title",
"url"
],
"properties": {
"url": {
"type": "string"
},
"title": {
"type": "string"
},
"clause": {
"type": "string"
},
"document": {
"type": "string"
}
},
"additionalProperties": false
}
},
"soundPressureLevel": {
"type": "number",
"description": "Combined A-weighted sound pressure level at the assessment position, in dB(A), rounded to one decimal place as MCS 020 requires."
}
},
"additionalProperties": false
},
"annotations": {
"title": "Heat pump noise assessment",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Compare what a household spends heating on its current fuel with what the same heat would cost from a heat pump. The heat demand is worked out from the household's own metered fuel use, not from a model, because a year of bills describes a particular house far better than any estimate of it. Supply the annual fuel use in the fuel's own unit (kWh for gas and electricity, litres for oil and LPG, kilograms for coal), its price per unit in pounds, and the seasonal efficiency of the existing appliance, which defaults to a realistic figure for that fuel instead of the one on the badge. The comparison turns on one ratio. A heat pump costs less to run whenever its seasonal coefficient of performance beats the ratio between the price of a unit of electricity and the price of a unit of heat from the current fuel. The result reports that break-even figure explicitly. SCOP must be the figure at the flow temperature the system is actually designed for. The same machine can return 4.2 at 35 degrees and 3.1 at 55, and quoting the first for a system designed at the second is the commonest way of overstating a saving. This is a running cost comparison. It says nothing about the capital cost or any grant. Method from MCS 007. These calculators follow the published MCS methods, for understanding a system and checking a quotation. Anything that gets installed still needs a design and a site survey from a certified installer.
| Parameter | Type | Description |
|---|---|---|
| fuel | string | The fuel being replaced: 'mains_gas', 'oil', 'lpg', 'electricity' or 'coal'. Defaults to 'mains_gas'. |
| scop * | number | Seasonal coefficient of performance of the proposed heat pump: the units of heat it delivers per unit of electricity, averaged over a year at the design flow temperature. Required. |
| annualFuelUse * | number | How much of that fuel the house uses in a year, in the fuel's own unit: kWh for gas and electricity, litres for oil and LPG, kilograms for coal. Take it from a year of bills. Required. |
| fuelPricePerUnit * | number | Price of one unit of that fuel, in pounds. Required. |
| nonHeatingFraction | number | Share of that fuel used for something other than heating and hot water, such as a gas hob, as a decimal. A hob is usually 0.03 to 0.05. Defaults to 0. |
| applianceEfficiency | number | Seasonal efficiency of the existing appliance, as a decimal. Defaults to the typical figure for the fuel. |
| electricityPricePerKwh * | number | Price of a unit of electricity, in pounds. Required. |
| fuelStandingChargePerDay | number | Daily standing charge for that fuel in pounds, if it has one. A house that removes its gas boiler can usually stop paying this. |
| electricityStandingChargePerDay | number | Daily electricity standing charge in pounds. It is paid either way, so it only changes the answer if the tariff changes with the heat pump. |
{
"name": "heat_pump_running_cost",
"title": "Heat pump running cost",
"description": "Compare what a household spends heating on its current fuel with what the same heat\nwould cost from a heat pump.\n\nThe heat demand is worked out from the household's own metered fuel use, not from a model,\nbecause a year of bills describes a particular house far better than any estimate of it. Supply the\nannual fuel use in the fuel's own unit (kWh for gas and electricity, litres for oil and LPG, kilograms\nfor coal), its price per unit in pounds, and the seasonal efficiency of the existing appliance, which\ndefaults to a realistic figure for that fuel instead of the one on the badge.\n\nThe comparison turns on one ratio. A heat pump costs less to run whenever its seasonal coefficient of\nperformance beats the ratio between the price of a unit of electricity and the price of a unit of heat\nfrom the current fuel. The result reports that break-even figure explicitly.\n\nSCOP must be the figure at the flow temperature the system is actually designed for. The same machine\ncan return 4.2 at 35 degrees and 3.1 at 55, and quoting the first for a system designed at the second\nis the commonest way of overstating a saving.\n\nThis is a running cost comparison. It says nothing about the capital cost or any grant.\n\nMethod from MCS 007. These calculators follow the published MCS methods, for understanding a system and checking a quotation. Anything that gets installed still needs a design and a site survey from a certified installer.",
"inputSchema": {
"type": "object",
"required": [
"annualFuelUse",
"fuelPricePerUnit",
"scop",
"electricityPricePerKwh"
],
"properties": {
"fuel": {
"type": "string",
"description": "The fuel being replaced: 'mains_gas', 'oil', 'lpg', 'electricity' or 'coal'. Defaults to 'mains_gas'."
},
"scop": {
"type": "number",
"description": "Seasonal coefficient of performance of the proposed heat pump: the units of heat it delivers per unit of electricity, averaged over a year at the design flow temperature. Required."
},
"annualFuelUse": {
"type": "number",
"description": "How much of that fuel the house uses in a year, in the fuel's own unit: kWh for gas and electricity, litres for oil and LPG, kilograms for coal. Take it from a year of bills. Required."
},
"fuelPricePerUnit": {
"type": "number",
"description": "Price of one unit of that fuel, in pounds. Required."
},
"nonHeatingFraction": {
"type": "number",
"description": "Share of that fuel used for something other than heating and hot water, such as a gas hob, as a decimal. A hob is usually 0.03 to 0.05. Defaults to 0."
},
"applianceEfficiency": {
"type": "number",
"description": "Seasonal efficiency of the existing appliance, as a decimal. Defaults to the typical figure for the fuel."
},
"electricityPricePerKwh": {
"type": "number",
"description": "Price of a unit of electricity, in pounds. Required."
},
"fuelStandingChargePerDay": {
"type": "number",
"description": "Daily standing charge for that fuel in pounds, if it has one. A house that removes its gas boiler can usually stop paying this."
},
"electricityStandingChargePerDay": {
"type": "number",
"description": "Daily electricity standing charge in pounds. It is paid either way, so it only changes the answer if the tariff changes with the heat pump."
}
},
"additionalProperties": false
},
"outputSchema": {
"type": "object",
"required": [
"fuel",
"applianceEfficiency",
"scop",
"annualHeatDemandKwh",
"currentAnnualCost",
"heatPumpAnnualCost",
"annualDifference",
"percentDifference",
"heatPumpElectricityKwh",
"costPerKwhHeatNow",
"costPerKwhHeatHeatPump",
"breakEvenScop",
"breakEvenPriceRatio",
"verdict",
"method",
"references",
"notes"
],
"properties": {
"fuel": {
"type": "object",
"required": [
"key",
"name",
"unit",
"kwhPerUnit",
"typicalEfficiency"
],
"properties": {
"key": {
"type": "string"
},
"name": {
"type": "string"
},
"unit": {
"type": "string",
"description": "The unit the fuel is normally metered or bought in."
},
"kwhPerUnit": {
"type": "number",
"description": "Energy in a single unit of that fuel."
},
"typicalEfficiency": {
"type": "number",
"description": "Seasonal efficiency of a reasonable appliance burning it, as a decimal."
}
},
"additionalProperties": false
},
"scop": {
"type": "number"
},
"notes": {
"type": [
"null",
"array"
],
"items": {
"type": "string"
}
},
"method": {
"type": "string"
},
"verdict": {
"type": "string"
},
"references": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"document",
"title",
"url"
],
"properties": {
"url": {
"type": "string"
},
"title": {
"type": "string"
},
"clause": {
"type": "string"
},
"document": {
"type": "string"
}
},
"additionalProperties": false
}
},
"breakEvenScop": {
"type": "number",
"description": "The seasonal efficiency at which the heat pump costs exactly what the current system costs. Below this it costs more."
},
"annualDifference": {
"type": "number",
"description": "Positive when the heat pump costs less."
},
"costPerKwhHeatNow": {
"type": "number",
"description": "What a unit of delivered heat costs today, in pounds."
},
"currentAnnualCost": {
"type": "number"
},
"percentDifference": {
"type": "number"
},
"heatPumpAnnualCost": {
"type": "number"
},
"annualHeatDemandKwh": {
"type": "number",
"description": "Useful heat the house actually needs in a year, after the existing appliance's losses are taken off its fuel input."
},
"applianceEfficiency": {
"type": "number"
},
"breakEvenPriceRatio": {
"type": "number",
"description": "How many times dearer a unit of electricity is than a unit of the current fuel. Compare it with the SCOP: a heat pump saves money whenever the SCOP beats this ratio."
},
"costPerKwhHeatHeatPump": {
"type": "number",
"description": "What a unit of delivered heat would cost from the heat pump."
},
"heatPumpElectricityKwh": {
"type": "number",
"description": "Units of electricity the heat pump would use in a year."
}
},
"additionalProperties": false
},
"annotations": {
"title": "Heat pump running cost",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Estimate the heat pump a UK house needs, and what it would cost to run against the fuel it burns now. IMPORTANT: MIS 3005-D requires a heat pump to be sized from a room-by-room heat loss calculation to BS EN 12831, and nothing here replaces that. Say so whenever you report a result from this, and point the user at the room-by-room calculation. What the figure is for is checking whether a size somebody has been quoted is plausible, because oversizing is the commonest fault in heat pump installations and it is invisible to the person living with it. There are two routes and the first is much the better one. From metered fuel, which is preferred: give 'annualFuelUse' from a year of bills. The fuel becomes heat delivered, hot water comes off it using the MIS 3005-D formula, and what remains divided by the local heating degree days gives the building's heat loss coefficient in watts per kelvin. Degree days are computed from the Met Office monthly means published in MGD 007 section 5. From the fabric, as a fallback when there are no bills: give 'floorAreaM2', an 'insulation' level and a 'propertyType'. The watts per kelvin per square metre behind this are a reasonable reading of British housing stock but they are NOT MCS figures, because MCS publishes no such shortcut. Say so when using this route. Either way the peak load is the coefficient multiplied by the design temperature difference for the location, from Table 2 of MIS 3005-D. The heat pump must deliver at least that at the design outside temperature and the design flow temperature, which is not the same as its headline rating. The result also compares what each of four flow temperatures would cost to run, which is the decision that governs the bill and the one a quotation most often leaves unstated. Supply 'quotedHeatPumpKw' to have a quoted size checked against the estimate. Method from MIS 3005-D. These calculators follow the published MCS methods, for understanding a system and checking a quotation. Anything that gets installed still needs a design and a site survey from a certified installer.
| Parameter | Type | Description |
|---|---|---|
| fuel | string | The fuel the house is heated with now: 'mains_gas', 'oil', 'lpg', 'electricity' or 'coal'. Defaults to 'mains_gas'. |
| scop | number | Seasonal coefficient of performance of the proposed heat pump, if it is known from the MCS Product Directory. Defaults to an indicative figure for the chosen flow temperature. |
| bedrooms | integer | Number of bedrooms, for the hot water demand. Defaults to 3. |
| location * | string | Nearest of the eight tabulated locations: 'belfast', 'birmingham', 'cardiff', 'edinburgh', 'glasgow', 'london', 'manchester' or 'plymouth'. Required. |
| occupants | integer | Number of people living there, if known. MIS 3005-D takes the greater of this and bedrooms plus one. |
| insulation | string | How well insulated the building is: 'solid', 'cavity_unfilled', 'insulated', 'modern' or 'very_efficient'. Used only with floorAreaM2. |
| designBasis | string | 'a' for the 99% outside design temperature or 'b' for the colder 99.6% one. Defaults to 'a'. |
| floorAreaM2 | number | Total heated floor area in square metres, over all storeys. Used only when no fuel figure is given. |
| internalTemp | number | Whole-house mean internal design temperature in Celsius. Defaults to 20, which is a reasonable average of the room-by-room figures in MIS 3005-D Table 1. |
| propertyType | string | 'detached', 'semi', 'end_terrace', 'mid_terrace', 'flat' or 'bungalow'. Used only with floorAreaM2. Defaults to 'semi'. |
| annualFuelUse | number | How much of that fuel the house burns in a year, in its own unit: kWh for gas and electricity, litres for oil and LPG, kilograms for coal. Give this if it is known: it describes the actual house and is far better than the fabric estimate. |
| flowTemperature | number | The flow temperature the system would be designed around: 35, 45, 50 or 55. Defaults to 45. This is the single biggest influence on running cost. |
| fuelPricePerUnit | number | Price of one unit of the current fuel, in pounds. Optional; supplying it and the electricity price gives a running cost comparison. |
| quotedHeatPumpKw | number | The output of a heat pump somebody has quoted, in kW. Optional; supplying it says whether that size looks plausible against this estimate. |
| nonHeatingFraction | number | Share of that fuel used for something other than heating and hot water, such as a gas hob, as a decimal. A hob is usually 0.03 to 0.05. Defaults to 0. |
| summerMonthFuelUse | number | Fuel used in a single summer month, in the same unit, when the heating is off. Give this if it can be found: almost all of it is hot water, so it separates hot water from space heating exactly and removes the biggest assumption in the estimate. |
| applianceEfficiency | number | Seasonal efficiency of the existing boiler as a decimal. Defaults to a realistic figure for the fuel instead of the one on the badge. |
| electricityPricePerKwh | number | Price of a unit of electricity, in pounds. Optional. |
{
"name": "heat_pump_size",
"title": "What size heat pump do I need?",
"description": "Estimate the heat pump a UK house needs, and what it would cost to run against the\nfuel it burns now.\n\nIMPORTANT: MIS 3005-D requires a heat pump to be sized from a room-by-room heat loss calculation to\nBS EN 12831, and nothing here replaces that. Say so whenever you report a result from this, and point\nthe user at the room-by-room calculation. What the figure is for is checking whether a size somebody\nhas been quoted is plausible, because oversizing is the commonest fault in heat pump installations and\nit is invisible to the person living with it.\n\nThere are two routes and the first is much the better one.\n\nFrom metered fuel, which is preferred: give 'annualFuelUse' from a year of bills. The fuel becomes heat\ndelivered, hot water comes off it using the MIS 3005-D formula, and what remains divided by the local\nheating degree days gives the building's heat loss coefficient in watts per kelvin. Degree days are\ncomputed from the Met Office monthly means published in MGD 007 section 5.\n\nFrom the fabric, as a fallback when there are no bills: give 'floorAreaM2', an 'insulation' level and a\n'propertyType'. The watts per kelvin per square metre behind this are a reasonable reading of British\nhousing stock but they are NOT MCS figures, because MCS publishes no such shortcut. Say so when using\nthis route.\n\nEither way the peak load is the coefficient multiplied by the design temperature difference for the\nlocation, from Table 2 of MIS 3005-D. The heat pump must deliver at least that at the design outside\ntemperature and the design flow temperature, which is not the same as its headline rating.\n\nThe result also compares what each of four flow temperatures would cost to run, which is the decision\nthat governs the bill and the one a quotation most often leaves unstated. Supply 'quotedHeatPumpKw' to\nhave a quoted size checked against the estimate.\n\nMethod from MIS 3005-D. These calculators follow the published MCS methods, for understanding a system and checking a quotation. Anything that gets installed still needs a design and a site survey from a certified installer.",
"inputSchema": {
"type": "object",
"required": [
"location"
],
"properties": {
"fuel": {
"type": "string",
"description": "The fuel the house is heated with now: 'mains_gas', 'oil', 'lpg', 'electricity' or 'coal'. Defaults to 'mains_gas'."
},
"scop": {
"type": "number",
"description": "Seasonal coefficient of performance of the proposed heat pump, if it is known from the MCS Product Directory. Defaults to an indicative figure for the chosen flow temperature."
},
"bedrooms": {
"type": "integer",
"description": "Number of bedrooms, for the hot water demand. Defaults to 3."
},
"location": {
"type": "string",
"description": "Nearest of the eight tabulated locations: 'belfast', 'birmingham', 'cardiff', 'edinburgh', 'glasgow', 'london', 'manchester' or 'plymouth'. Required."
},
"occupants": {
"type": "integer",
"description": "Number of people living there, if known. MIS 3005-D takes the greater of this and bedrooms plus one."
},
"insulation": {
"type": "string",
"description": "How well insulated the building is: 'solid', 'cavity_unfilled', 'insulated', 'modern' or 'very_efficient'. Used only with floorAreaM2."
},
"designBasis": {
"type": "string",
"description": "'a' for the 99% outside design temperature or 'b' for the colder 99.6% one. Defaults to 'a'."
},
"floorAreaM2": {
"type": "number",
"description": "Total heated floor area in square metres, over all storeys. Used only when no fuel figure is given."
},
"internalTemp": {
"type": "number",
"description": "Whole-house mean internal design temperature in Celsius. Defaults to 20, which is a reasonable average of the room-by-room figures in MIS 3005-D Table 1."
},
"propertyType": {
"type": "string",
"description": "'detached', 'semi', 'end_terrace', 'mid_terrace', 'flat' or 'bungalow'. Used only with floorAreaM2. Defaults to 'semi'."
},
"annualFuelUse": {
"type": "number",
"description": "How much of that fuel the house burns in a year, in its own unit: kWh for gas and electricity, litres for oil and LPG, kilograms for coal. Give this if it is known: it describes the actual house and is far better than the fabric estimate."
},
"flowTemperature": {
"type": "number",
"description": "The flow temperature the system would be designed around: 35, 45, 50 or 55. Defaults to 45. This is the single biggest influence on running cost."
},
"fuelPricePerUnit": {
"type": "number",
"description": "Price of one unit of the current fuel, in pounds. Optional; supplying it and the electricity price gives a running cost comparison."
},
"quotedHeatPumpKw": {
"type": "number",
"description": "The output of a heat pump somebody has quoted, in kW. Optional; supplying it says whether that size looks plausible against this estimate."
},
"nonHeatingFraction": {
"type": "number",
"description": "Share of that fuel used for something other than heating and hot water, such as a gas hob, as a decimal. A hob is usually 0.03 to 0.05. Defaults to 0."
},
"summerMonthFuelUse": {
"type": "number",
"description": "Fuel used in a single summer month, in the same unit, when the heating is off. Give this if it can be found: almost all of it is hot water, so it separates hot water from space heating exactly and removes the biggest assumption in the estimate."
},
"applianceEfficiency": {
"type": "number",
"description": "Seasonal efficiency of the existing boiler as a decimal. Defaults to a realistic figure for the fuel instead of the one on the badge."
},
"electricityPricePerKwh": {
"type": "number",
"description": "Price of a unit of electricity, in pounds. Optional."
}
},
"additionalProperties": false
},
"outputSchema": {
"type": "object",
"required": [
"location",
"basis",
"basisNote",
"designBasis",
"internalTemp",
"externalDesignTemp",
"temperatureDifference",
"heatingDegreeDays",
"heatLossCoefficientWPerK",
"peakHeatLossKw",
"annualSpaceHeatingKwh",
"annualHotWaterKwh",
"hotWaterFromSummerUse",
"annualHeatDemandKwh",
"dailyHotWaterLitres",
"flowTemperature",
"scop",
"scopAssumed",
"heatPumpElectricityKwh",
"method",
"references",
"notes",
"warning"
],
"properties": {
"scop": {
"type": "number"
},
"basis": {
"type": "string"
},
"notes": {
"type": [
"null",
"array"
],
"items": {
"type": "string"
}
},
"method": {
"type": "string"
},
"warning": {
"type": "string"
},
"location": {
"type": "object",
"required": [
"name",
"altitudeM",
"designTempA",
"designTempB",
"annualMeanTemp",
"metOfficeStation",
"heatingDegreeDays"
],
"properties": {
"name": {
"type": "string"
},
"altitudeM": {
"type": "integer"
},
"designTempA": {
"type": "number",
"description": "Hourly dry-bulb temperature exceeded for 99% of the hours in a year."
},
"designTempB": {
"type": "number",
"description": "The colder 99.6% figure. Using it removes the need for any uplift for intermittent heating."
},
"annualMeanTemp": {
"type": "number"
},
"metOfficeStation": {
"type": "string"
},
"heatingDegreeDays": {
"type": "number"
}
},
"additionalProperties": false
},
"basisNote": {
"type": "string"
},
"references": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"document",
"title",
"url"
],
"properties": {
"url": {
"type": "string"
},
"title": {
"type": "string"
},
"clause": {
"type": "string"
},
"document": {
"type": "string"
}
},
"additionalProperties": false
}
},
"designBasis": {
"type": "string"
},
"scopAssumed": {
"type": "boolean",
"description": "True when an indicative figure stood in for a real one from the product directory."
},
"internalTemp": {
"type": "number"
},
"breakEvenScop": {
"type": "number",
"description": "The seasonal efficiency at which the two cost the same."
},
"peakHeatLossKw": {
"type": "number",
"description": "The space heating load at the design outside temperature. The heat pump must deliver at least this, at the design flow temperature, without help from an immersion heater."
},
"flowTemperature": {
"type": "number"
},
"quotedSizeCheck": {
"type": [
"null",
"object"
],
"required": [
"quotedKw",
"ratioToEstimate",
"verdict",
"plausible"
],
"properties": {
"verdict": {
"type": "string"
},
"quotedKw": {
"type": "number"
},
"plausible": {
"type": "boolean",
"description": "False when the quoted unit looks considerably larger than the house appears to need, which is worth questioning."
},
"ratioToEstimate": {
"type": "number",
"description": "The quoted output divided by the estimated peak load."
}
},
"additionalProperties": false
},
"annualDifference": {
"type": "number",
"description": "Positive when the heat pump costs less."
},
"annualHotWaterKwh": {
"type": "number"
},
"currentAnnualCost": {
"type": "number"
},
"heatingDegreeDays": {
"type": "number"
},
"externalDesignTemp": {
"type": "number"
},
"heatPumpAnnualCost": {
"type": "number"
},
"annualHeatDemandKwh": {
"type": "number"
},
"dailyHotWaterLitres": {
"type": "number"
},
"wattsPerSquareMetre": {
"type": "number",
"description": "Peak load per square metre of floor, where a floor area was given. A useful sanity check."
},
"flowTemperatureCosts": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"flowTemperature",
"label",
"indicativeScop",
"electricityKwh",
"description",
"chosen"
],
"properties": {
"label": {
"type": "string"
},
"chosen": {
"type": "boolean"
},
"annualCost": {
"type": "number"
},
"description": {
"type": "string"
},
"electricityKwh": {
"type": "number"
},
"indicativeScop": {
"type": "number"
},
"flowTemperature": {
"type": "number"
}
},
"additionalProperties": false
}
},
"annualSpaceHeatingKwh": {
"type": "number"
},
"hotWaterFromSummerUse": {
"type": "boolean",
"description": "True when a summer month's fuel separated hot water from space heating, instead of an allowance standing in for it."
},
"temperatureDifference": {
"type": "number"
},
"heatPumpElectricityKwh": {
"type": "number"
},
"heatLossCoefficientWPerK": {
"type": "number",
"description": "How many watts the building loses for every degree between inside and outside. The figure everything else follows from."
}
},
"additionalProperties": false
},
"annotations": {
"title": "What size heat pump do I need?",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Work out the daily hot water demand of a dwelling and the size of cylinder a heat pump needs, using the formula in MIS 3005-D 3.5.2 and the BS 6700 guidance reproduced in MGD 007. The demand is 45 litres a day for each of N, where N is the greater of the number of bedrooms plus one and the number of people actually living there. For a new build, where occupancy is unknown, the bedroom count is used. The cylinder does not have to hold a whole day's demand, because it reheats as it empties. What it must cover is the largest draw-off before the heat pump catches up, which is why a larger heat pump needs a smaller cylinder: reheat time is volume times temperature rise, divided by 14.3 times the kW. The result gives the BS 6700 minimum, a recommended size rounded to a volume cylinders are made in, and the reheat time. Note that cylinder volume is not the whole story: a heat pump cylinder needs a much larger coil than a boiler cylinder, because the water arrives cooler and there is less temperature difference to drive heat across the surface. Method from MIS 3005-D. These calculators follow the published MCS methods, for understanding a system and checking a quotation. Anything that gets installed still needs a design and a site survey from a certified installer.
| Parameter | Type | Description |
|---|---|---|
| bedrooms * | integer | Number of bedrooms in the property. Required. |
| bathrooms | integer | Number of bathrooms with a bath. Defaults to 1. |
| occupants | integer | Number of people who actually live there, if known. MIS 3005-D takes the greater of this and bedrooms plus one. Leave it out for a new build, where the occupancy is not yet known. |
| storageTemp | number | Temperature the cylinder is stored at, in Celsius. Defaults to 55, which is a common heat pump setting. A weekly pasteurisation cycle above 60 is separate. |
| coldWaterTemp | number | Incoming mains temperature in Celsius. Defaults to 10. |
| heatPumpOutputKw | number | Heat output of the heat pump in kW when it is heating the cylinder. A larger heat pump reheats faster, so it needs less stored volume. Defaults to 6. |
{
"name": "hot_water_cylinder",
"title": "Hot water demand and cylinder size",
"description": "Work out the daily hot water demand of a dwelling and the size of cylinder a heat\npump needs, using the formula in MIS 3005-D 3.5.2 and the BS 6700 guidance reproduced in MGD 007.\n\nThe demand is 45 litres a day for each of N, where N is the greater of the number of bedrooms plus one\nand the number of people actually living there. For a new build, where occupancy is unknown, the\nbedroom count is used.\n\nThe cylinder does not have to hold a whole day's demand, because it reheats as it empties. What it must\ncover is the largest draw-off before the heat pump catches up, which is why a larger heat pump needs a\nsmaller cylinder: reheat time is volume times temperature rise, divided by 14.3 times the kW.\n\nThe result gives the BS 6700 minimum, a recommended size rounded to a volume cylinders are made in, and\nthe reheat time. Note that cylinder volume is not the whole story: a heat pump cylinder needs a much\nlarger coil than a boiler cylinder, because the water arrives cooler and there is less temperature\ndifference to drive heat across the surface.\n\nMethod from MIS 3005-D. These calculators follow the published MCS methods, for understanding a system and checking a quotation. Anything that gets installed still needs a design and a site survey from a certified installer.",
"inputSchema": {
"type": "object",
"required": [
"bedrooms"
],
"properties": {
"bedrooms": {
"type": "integer",
"description": "Number of bedrooms in the property. Required."
},
"bathrooms": {
"type": "integer",
"description": "Number of bathrooms with a bath. Defaults to 1."
},
"occupants": {
"type": "integer",
"description": "Number of people who actually live there, if known. MIS 3005-D takes the greater of this and bedrooms plus one. Leave it out for a new build, where the occupancy is not yet known."
},
"storageTemp": {
"type": "number",
"description": "Temperature the cylinder is stored at, in Celsius. Defaults to 55, which is a common heat pump setting. A weekly pasteurisation cycle above 60 is separate."
},
"coldWaterTemp": {
"type": "number",
"description": "Incoming mains temperature in Celsius. Defaults to 10."
},
"heatPumpOutputKw": {
"type": "number",
"description": "Heat output of the heat pump in kW when it is heating the cylinder. A larger heat pump reheats faster, so it needs less stored volume. Defaults to 6."
}
},
"additionalProperties": false
},
"outputSchema": {
"type": "object",
"required": [
"bedrooms",
"designOccupancy",
"occupancyBasis",
"dailyDemandLitres",
"recommendedCylinderLitres",
"minimumCylinderLitres",
"reheatMinutes",
"energyPerDayKwh",
"heatPumpOutputKw",
"storageTemp",
"coldWaterTemp",
"bathrooms",
"method",
"references",
"notes"
],
"properties": {
"notes": {
"type": [
"null",
"array"
],
"items": {
"type": "string"
}
},
"method": {
"type": "string"
},
"bedrooms": {
"type": "integer"
},
"bathrooms": {
"type": "integer"
},
"occupants": {
"type": "integer"
},
"references": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"document",
"title",
"url"
],
"properties": {
"url": {
"type": "string"
},
"title": {
"type": "string"
},
"clause": {
"type": "string"
},
"document": {
"type": "string"
}
},
"additionalProperties": false
}
},
"storageTemp": {
"type": "number"
},
"coldWaterTemp": {
"type": "number"
},
"reheatMinutes": {
"type": "number",
"description": "Roughly how long the heat pump takes to bring the whole cylinder up from cold, ignoring standing losses."
},
"occupancyBasis": {
"type": "string",
"description": "Which of the two gave the larger figure."
},
"designOccupancy": {
"type": "integer",
"description": "N in the MIS 3005-D formula: the greater of bedrooms plus one and the known occupants."
},
"energyPerDayKwh": {
"type": "number",
"description": "Heat needed each day to raise the daily demand from mains temperature to storage temperature."
},
"heatPumpOutputKw": {
"type": "number"
},
"dailyDemandLitres": {
"type": "number",
"description": "Average daily hot water demand: 45 litres for each of N."
},
"minimumCylinderLitres": {
"type": "integer",
"description": "The BS 6700 minimum for this number of bathrooms and this heat pump output, before the allowance MGD 007 adds for extra bathing capacity."
},
"recommendedCylinderLitres": {
"type": "integer",
"description": "Cylinder volume from the BS 6700 guidance in MGD 007, given the number of baths and the heat pump output."
}
},
"additionalProperties": false
},
"annotations": {
"title": "Hot water demand and cylinder size",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Lists every calculator on this server, with the standard behind it and whether it is the whole-system sizing calculator or one of the single-method ones, plus the reference data a caller needs to build a valid request: the compass directions and their orientations, the shading descriptions, the twenty-five solar postcode zones, the eight heat pump design locations with their design temperatures, the room types and their internal design temperatures, the heat loss element kinds, the occupancy archetypes and the fuel types. Call this when a value must be one of a fixed set and you are not sure what the set is.
No parameters.
{
"name": "list_calculators",
"title": "List the calculators and their reference data",
"description": "Lists every calculator on this server, with the standard behind it and whether it is the whole-system sizing calculator or one of the single-method ones, plus the reference data a caller needs to build a valid request: the compass directions and their orientations, the shading descriptions, the twenty-five solar postcode zones, the eight heat pump design locations with their design temperatures, the room types and their internal design temperatures, the heat loss element kinds, the occupancy archetypes and the fuel types. Call this when a value must be one of a fixed set and you are not sure what the set is.",
"inputSchema": {
"type": "object",
"additionalProperties": false
},
"outputSchema": {
"type": "object",
"required": [
"calculators",
"reference",
"notice"
],
"properties": {
"notice": {
"type": "string"
},
"reference": {
"type": "object",
"required": [
"compassDirections",
"shadingLevels",
"insulationLevels",
"propertyTypes",
"flowTemperatureOptions",
"solarPostcodeZones",
"heatLossDesignLocations",
"roomTypes",
"heatLossElementKinds",
"occupancyArchetypes",
"fuelTypes"
],
"properties": {
"fuelTypes": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"key",
"name",
"unit",
"kwhPerUnit",
"typicalEfficiency"
],
"properties": {
"key": {
"type": "string"
},
"name": {
"type": "string"
},
"unit": {
"type": "string",
"description": "The unit the fuel is normally metered or bought in."
},
"kwhPerUnit": {
"type": "number",
"description": "Energy in a single unit of that fuel."
},
"typicalEfficiency": {
"type": "number",
"description": "Seasonal efficiency of a reasonable appliance burning it, as a decimal."
}
},
"additionalProperties": false
},
"description": "Heating fuels a running cost comparison can be made against."
},
"roomTypes": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"key",
"name",
"internalTemp"
],
"properties": {
"key": {
"type": "string"
},
"name": {
"type": "string"
},
"internalTemp": {
"type": "number"
}
},
"additionalProperties": false
},
"description": "Room types and their minimum internal design temperatures."
},
"propertyTypes": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"key",
"label",
"multiplier"
],
"properties": {
"key": {
"type": "string"
},
"label": {
"type": "string"
},
"multiplier": {
"type": "number"
}
},
"additionalProperties": false
},
"description": "Building shapes, and how much each changes an exposed-surface estimate."
},
"shadingLevels": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"key",
"label",
"sunpathSegments",
"shadeFactor",
"description"
],
"properties": {
"key": {
"type": "string"
},
"label": {
"type": "string"
},
"description": {
"type": "string"
},
"shadeFactor": {
"type": "number"
},
"sunpathSegments": {
"type": "integer",
"description": "The equivalent count on the MGD 005 sunpath chart, out of 84."
}
},
"additionalProperties": false
},
"description": "Shading described in words, each anchored to a segment count on the MGD 005 sunpath chart."
},
"insulationLevels": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"key",
"label",
"wattsPerKelvinPerSquareMetre",
"description"
],
"properties": {
"key": {
"type": "string"
},
"label": {
"type": "string"
},
"description": {
"type": "string"
},
"wattsPerKelvinPerSquareMetre": {
"type": "number"
}
},
"additionalProperties": false
},
"description": "Fabric descriptions for the heat pump sizer's fallback route. Indicative readings of British housing stock, not MCS figures."
},
"compassDirections": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"key",
"label",
"orientation"
],
"properties": {
"key": {
"type": "string"
},
"label": {
"type": "string"
},
"orientation": {
"type": "number",
"description": "Degrees from due south, as MIS 3002 measures it."
}
},
"additionalProperties": false
},
"description": "The eight compass points the sizing calculator accepts, with the orientation in degrees from south that each maps to."
},
"solarPostcodeZones": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"code",
"city"
],
"properties": {
"city": {
"type": "string"
},
"code": {
"type": "string"
}
},
"additionalProperties": false
},
"description": "The 25 MCS solar zones. Resolved automatically from a postcode, so only needed when a postcode is unavailable."
},
"occupancyArchetypes": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"value",
"label",
"description"
],
"properties": {
"label": {
"type": "string"
},
"value": {
"type": "string"
},
"description": {
"type": "string"
}
},
"additionalProperties": false
},
"description": "The three MGD 003 weekday occupancy patterns."
},
"heatLossElementKinds": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"key",
"name",
"description"
],
"properties": {
"key": {
"type": "string"
},
"name": {
"type": "string"
},
"description": {
"type": "string"
}
},
"additionalProperties": false
},
"description": "The kinds of surface a room loses heat through, and which temperature difference each uses."
},
"flowTemperatureOptions": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"flowTemperature",
"label",
"indicativeScop",
"description"
],
"properties": {
"label": {
"type": "string"
},
"description": {
"type": "string"
},
"indicativeScop": {
"type": "number"
},
"flowTemperature": {
"type": "number"
}
},
"additionalProperties": false
},
"description": "The four flow temperatures the heat pump sizer compares, with what each usually means for the emitters and an indicative seasonal efficiency."
},
"heatLossDesignLocations": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"name",
"altitudeM",
"designTempA",
"designTempB",
"annualMeanTemp",
"metOfficeStation",
"heatingDegreeDays"
],
"properties": {
"name": {
"type": "string"
},
"altitudeM": {
"type": "integer"
},
"designTempA": {
"type": "number",
"description": "Hourly dry-bulb temperature exceeded for 99% of the hours in a year."
},
"designTempB": {
"type": "number",
"description": "The colder 99.6% figure. Using it removes the need for any uplift for intermittent heating."
},
"annualMeanTemp": {
"type": "number"
},
"metOfficeStation": {
"type": "string"
},
"heatingDegreeDays": {
"type": "number"
}
},
"additionalProperties": false
},
"description": "The eight locations MIS 3005-D tabulates outside design temperatures for."
}
},
"additionalProperties": false
},
"calculators": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"id",
"title",
"summary",
"standard",
"category",
"tier"
],
"properties": {
"id": {
"type": "string"
},
"tier": {
"type": "string",
"description": "'simple' for the whole-system sizing calculator, 'advanced' for the ones that each implement a single published method."
},
"title": {
"type": "string"
},
"summary": {
"type": "string"
},
"category": {
"type": "string"
},
"standard": {
"type": "string"
}
},
"additionalProperties": false
}
}
},
"additionalProperties": false
},
"annotations": {
"title": "List the calculators and their reference data",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Work out the flow temperature a heat pump must produce to heat a room through a given radiator, and the resulting MCS Heat Emitter Guide star rating, following section 4 of MGD 007. This is the calculation that decides whether a heat pump will be cheap or expensive to run. A heat pump's efficiency falls as the water temperature rises, by roughly two to three per cent per degree, and the temperature it must produce is set by the radiators, not by the machine. Supply the room's design heat loss in watts, from a room-by-room calculation, and the rated output of the radiator in that room. British catalogues normally quote at a mean-water-to-air difference of 50 K; if yours quotes 60, say so and the figure is restated. The result gives the oversize factor, which is the radiator's output at 50 K divided by the room's heat loss, and converts it to a required flow temperature through the BS EN 442 output law. Star ratings run from 0 to 6, one star per five degrees of flow temperature, with six stars at 35 degrees. Run this for every room. A house runs at the flow temperature its worst room demands, so one undersized radiator sets the running cost for the whole house. Method from MGD 007. These calculators follow the published MCS methods, for understanding a system and checking a quotation. Anything that gets installed still needs a design and a site survey from a certified installer.
| Parameter | Type | Description |
|---|---|---|
| roomTemp | number | Internal design temperature of the room in Celsius. Defaults to 21. |
| systemDeltaT | number | Designed drop in water temperature between flow and return, in kelvin. Heat pump systems commonly use 5; boiler systems used 10 or 20. Defaults to 5. |
| ratedAtDeltaT | number | The mean-water-to-air temperature difference the rated output was quoted at. British catalogues normally quote 50; some older ones quote 60. Defaults to 50. |
| roomHeatLossW * | number | The room's design heat loss in watts, from a room-by-room heat loss calculation. Required. |
| radiatorOutputW * | number | Rated output of the radiator or radiators in that room, in watts, at the catalogue temperature. Required. |
{
"name": "radiator_flow_temperature",
"title": "Radiator flow temperature",
"description": "Work out the flow temperature a heat pump must produce to heat a room through a\ngiven radiator, and the resulting MCS Heat Emitter Guide star rating, following section 4 of MGD 007.\n\nThis is the calculation that decides whether a heat pump will be cheap or expensive to run. A heat\npump's efficiency falls as the water temperature rises, by roughly two to three per cent per degree,\nand the temperature it must produce is set by the radiators, not by the machine.\n\nSupply the room's design heat loss in watts, from a room-by-room calculation, and the rated output of\nthe radiator in that room. British catalogues normally quote at a mean-water-to-air difference of 50 K;\nif yours quotes 60, say so and the figure is restated.\n\nThe result gives the oversize factor, which is the radiator's output at 50 K divided by the room's heat\nloss, and converts it to a required flow temperature through the BS EN 442 output law. Star ratings run\nfrom 0 to 6, one star per five degrees of flow temperature, with six stars at 35 degrees.\n\nRun this for every room. A house runs at the flow temperature its worst room demands, so one undersized\nradiator sets the running cost for the whole house.\n\nMethod from MGD 007. These calculators follow the published MCS methods, for understanding a system and checking a quotation. Anything that gets installed still needs a design and a site survey from a certified installer.",
"inputSchema": {
"type": "object",
"required": [
"roomHeatLossW",
"radiatorOutputW"
],
"properties": {
"roomTemp": {
"type": "number",
"description": "Internal design temperature of the room in Celsius. Defaults to 21."
},
"systemDeltaT": {
"type": "number",
"description": "Designed drop in water temperature between flow and return, in kelvin. Heat pump systems commonly use 5; boiler systems used 10 or 20. Defaults to 5."
},
"ratedAtDeltaT": {
"type": "number",
"description": "The mean-water-to-air temperature difference the rated output was quoted at. British catalogues normally quote 50; some older ones quote 60. Defaults to 50."
},
"roomHeatLossW": {
"type": "number",
"description": "The room's design heat loss in watts, from a room-by-room heat loss calculation. Required."
},
"radiatorOutputW": {
"type": "number",
"description": "Rated output of the radiator or radiators in that room, in watts, at the catalogue temperature. Required."
}
},
"additionalProperties": false
},
"outputSchema": {
"type": "object",
"required": [
"roomHeatLossW",
"radiatorOutputW",
"ratedAtDeltaT",
"outputAtDeltaT50",
"oversizeFactor",
"meanWaterTemp",
"flowTemperature",
"returnTemperature",
"starRating",
"starRatingLabel",
"verdict",
"outputAtDesignFlowW",
"radiatorOutputForFiveStarsW",
"method",
"references",
"notes"
],
"properties": {
"notes": {
"type": [
"null",
"array"
],
"items": {
"type": "string"
}
},
"method": {
"type": "string"
},
"verdict": {
"type": "string"
},
"references": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"document",
"title",
"url"
],
"properties": {
"url": {
"type": "string"
},
"title": {
"type": "string"
},
"clause": {
"type": "string"
},
"document": {
"type": "string"
}
},
"additionalProperties": false
}
},
"starRating": {
"type": "integer",
"description": "Temperature star rating from the MCS Heat Emitter Guide, 0 to 6. More stars mean a lower flow temperature and a more efficient system."
},
"meanWaterTemp": {
"type": "number",
"description": "Average of flow and return temperature needed to deliver the room's heat loss through this radiator."
},
"ratedAtDeltaT": {
"type": "number"
},
"roomHeatLossW": {
"type": "number"
},
"oversizeFactor": {
"type": "number",
"description": "Radiator output at 50 K divided by the room's heat loss. The single number the Heat Emitter Guide turns into a star rating."
},
"flowTemperature": {
"type": "number",
"description": "The flow temperature the heat pump must produce, in Celsius."
},
"radiatorOutputW": {
"type": "number"
},
"starRatingLabel": {
"type": "string"
},
"outputAtDeltaT50": {
"type": "number",
"description": "The radiator's output restated at a mean-water-to-air difference of 50 K, so oversize factors are comparable between catalogues."
},
"returnTemperature": {
"type": "number"
},
"outputAtDesignFlowW": {
"type": "number",
"description": "What this radiator actually gives at the flow temperature worked out here."
},
"radiatorOutputForFiveStarsW": {
"type": "number",
"description": "The radiator output at 50 K that would reach a five star rating, meaning a 40 degree flow temperature."
}
},
"additionalProperties": false
},
"annotations": {
"title": "Radiator flow temperature",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Calculate the design heat loss of a single room in watts, following BS EN 12831 as MIS 3005-D applies it. This is the figure a heat pump is sized from and the figure the radiator in that room must be able to deliver. BS EN 12831 is a room-by-room method. Run this once for each heated room and add the results; sizing a heat pump from floor area alone is what produces the oversized installations that cycle all winter. Internal design temperatures come from Table 1 of MIS 3005-D and follow from the room type: 22 for a bathroom, 21 for living and dining rooms, 18 for bedrooms, halls, kitchens and toilets. These are minimums, so a higher figure is accepted and a lower one is refused. External design temperatures come from Table 2, for eight locations, in two columns: 'a' is the 99% figure and 'b' the colder 99.6% one, which needs no uplift for intermittent heating. Each element needs an area, a U-value, and a kind. The kind matters because it fixes which temperature difference applies. Walls, windows, doors, roofs and suspended floors lose heat to the outside design temperature. A SOLID FLOOR ON THE GROUND loses heat to the local annual average air temperature instead, which is far warmer, and getting this wrong is the commonest error in a heat loss calculation. Window and door areas belong to the window and the door, not to the wall behind them. Method from MIS 3005-D. These calculators follow the published MCS methods, for understanding a system and checking a quotation. Anything that gets installed still needs a design and a site survey from a certified installer.
| Parameter | Type | Description |
|---|---|---|
| elements * | ["null","array"] | Every surface through which the room loses heat. At least one is required. |
| location * | string | Which of the eight tabulated locations the property is nearest: 'belfast', 'birmingham', 'cardiff', 'edinburgh', 'glasgow', 'london', 'manchester' or 'plymouth'. Required. |
| roomName | string | A name for the room. |
| roomType | string | Which of the tabulated room types this is: 'living_room', 'dining_room', 'bedsitting_room', 'bathroom', 'bedroom', 'kitchen', 'hall' or 'toilet'. Sets the internal design temperature. Defaults to 'living_room'. |
| designBasis | string | 'a' for the 99% outside design temperature or 'b' for the colder 99.6% figure. Column B needs no uplift for intermittent heating. Defaults to 'a'. |
| floorAreaM2 * | number | Floor area of the room in square metres. Required, and used with the ceiling height to work out the ventilation loss. |
| internalTemp | number | Internal design temperature in Celsius, if it should differ from the tabulated value for the room type. MIS 3005-D sets the tabulated values as a floor, not a target, so a higher figure is allowed and a lower one is not. |
| ceilingHeightM | number | Floor to ceiling height in metres. Defaults to 2.4. |
| airChangesPerHour | number | How many times an hour the air in the room is replaced. A draughty old room may be 1.5 or more; a well sealed new one 0.5. Defaults to 1. |
{
"name": "room_heat_loss",
"title": "Room heat loss",
"description": "Calculate the design heat loss of a single room in watts, following BS EN 12831 as\nMIS 3005-D applies it. This is the figure a heat pump is sized from and the figure the radiator in\nthat room must be able to deliver.\n\nBS EN 12831 is a room-by-room method. Run this once for each heated room and add the results; sizing\na heat pump from floor area alone is what produces the oversized installations that cycle all winter.\n\nInternal design temperatures come from Table 1 of MIS 3005-D and follow from the room type: 22 for a\nbathroom, 21 for living and dining rooms, 18 for bedrooms, halls, kitchens and toilets. These are\nminimums, so a higher figure is accepted and a lower one is refused.\n\nExternal design temperatures come from Table 2, for eight locations, in two columns: 'a' is the 99%\nfigure and 'b' the colder 99.6% one, which needs no uplift for intermittent heating.\n\nEach element needs an area, a U-value, and a kind. The kind matters because it fixes which temperature\ndifference applies. Walls, windows, doors, roofs and suspended floors lose heat to the outside design\ntemperature. A SOLID FLOOR ON THE GROUND loses heat to the local annual average air temperature\ninstead, which is far warmer, and getting this wrong is the commonest error in a heat loss calculation.\nWindow and door areas belong to the window and the door, not to the wall behind them.\n\nMethod from MIS 3005-D. These calculators follow the published MCS methods, for understanding a system and checking a quotation. Anything that gets installed still needs a design and a site survey from a certified installer.",
"inputSchema": {
"type": "object",
"required": [
"location",
"floorAreaM2",
"elements"
],
"properties": {
"elements": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"kind",
"areaM2",
"uValue"
],
"properties": {
"kind": {
"type": "string",
"description": "One of 'external_wall', 'window', 'door', 'roof', 'suspended_floor', 'ground_floor' or 'unheated_space'. Required."
},
"label": {
"type": "string",
"description": "A name for this element, so the result can be read back against the survey."
},
"areaM2": {
"type": "number",
"description": "Area of the element in square metres. Window and door areas are taken out of the wall area, not counted twice. Required."
},
"uValue": {
"type": "number",
"description": "U-value in W/m2K: the watts lost through each square metre for every degree of temperature difference. Required."
},
"unheatedTemp": {
"type": "number",
"description": "Temperature of the unheated space on the other side, in Celsius. Only used for the 'unheated_space' kind. Defaults to halfway between inside and outside."
}
},
"additionalProperties": false
},
"description": "Every surface through which the room loses heat. At least one is required."
},
"location": {
"type": "string",
"description": "Which of the eight tabulated locations the property is nearest: 'belfast', 'birmingham', 'cardiff', 'edinburgh', 'glasgow', 'london', 'manchester' or 'plymouth'. Required."
},
"roomName": {
"type": "string",
"description": "A name for the room."
},
"roomType": {
"type": "string",
"description": "Which of the tabulated room types this is: 'living_room', 'dining_room', 'bedsitting_room', 'bathroom', 'bedroom', 'kitchen', 'hall' or 'toilet'. Sets the internal design temperature. Defaults to 'living_room'."
},
"designBasis": {
"type": "string",
"description": "'a' for the 99% outside design temperature or 'b' for the colder 99.6% figure. Column B needs no uplift for intermittent heating. Defaults to 'a'."
},
"floorAreaM2": {
"type": "number",
"description": "Floor area of the room in square metres. Required, and used with the ceiling height to work out the ventilation loss."
},
"internalTemp": {
"type": "number",
"description": "Internal design temperature in Celsius, if it should differ from the tabulated value for the room type. MIS 3005-D sets the tabulated values as a floor, not a target, so a higher figure is allowed and a lower one is not."
},
"ceilingHeightM": {
"type": "number",
"description": "Floor to ceiling height in metres. Defaults to 2.4."
},
"airChangesPerHour": {
"type": "number",
"description": "How many times an hour the air in the room is replaced. A draughty old room may be 1.5 or more; a well sealed new one 0.5. Defaults to 1."
}
},
"additionalProperties": false
},
"outputSchema": {
"type": "object",
"required": [
"roomType",
"internalTemp",
"location",
"designBasis",
"externalDesignTemp",
"temperatureDifference",
"elements",
"fabricLossW",
"ventilationLossW",
"totalHeatLossW",
"roomVolumeM3",
"wattsPerSquareMetre",
"fabricSharePercent",
"ventilationSharePercent",
"method",
"references",
"notes"
],
"properties": {
"notes": {
"type": [
"null",
"array"
],
"items": {
"type": "string"
}
},
"method": {
"type": "string"
},
"elements": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"kind",
"kindName",
"areaM2",
"uValue",
"otherSideTemp",
"temperatureDifference",
"lossW",
"sharePercent"
],
"properties": {
"kind": {
"type": "string"
},
"label": {
"type": "string"
},
"lossW": {
"type": "number"
},
"areaM2": {
"type": "number"
},
"uValue": {
"type": "number"
},
"kindName": {
"type": "string"
},
"sharePercent": {
"type": "number"
},
"otherSideTemp": {
"type": "number"
},
"temperatureDifference": {
"type": "number"
}
},
"additionalProperties": false
}
},
"location": {
"type": "object",
"required": [
"name",
"altitudeM",
"designTempA",
"designTempB",
"annualMeanTemp",
"metOfficeStation",
"heatingDegreeDays"
],
"properties": {
"name": {
"type": "string"
},
"altitudeM": {
"type": "integer"
},
"designTempA": {
"type": "number",
"description": "Hourly dry-bulb temperature exceeded for 99% of the hours in a year."
},
"designTempB": {
"type": "number",
"description": "The colder 99.6% figure. Using it removes the need for any uplift for intermittent heating."
},
"annualMeanTemp": {
"type": "number"
},
"metOfficeStation": {
"type": "string"
},
"heatingDegreeDays": {
"type": "number"
}
},
"additionalProperties": false
},
"roomName": {
"type": "string"
},
"roomType": {
"type": "string"
},
"references": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"document",
"title",
"url"
],
"properties": {
"url": {
"type": "string"
},
"title": {
"type": "string"
},
"clause": {
"type": "string"
},
"document": {
"type": "string"
}
},
"additionalProperties": false
}
},
"designBasis": {
"type": "string"
},
"fabricLossW": {
"type": "number"
},
"largestLoss": {
"type": "string",
"description": "Which single element loses most, which is where insulating first pays best."
},
"internalTemp": {
"type": "number"
},
"roomVolumeM3": {
"type": "number"
},
"totalHeatLossW": {
"type": "number",
"description": "The room's design heat loss in watts. This is what the emitter in the room has to deliver on the coldest day."
},
"ventilationLossW": {
"type": "number"
},
"externalDesignTemp": {
"type": "number"
},
"fabricSharePercent": {
"type": "number"
},
"wattsPerSquareMetre": {
"type": "number",
"description": "Heat loss divided by floor area. A useful sanity check: a well insulated room lands near 40, a poor one well over 100."
},
"temperatureDifference": {
"type": "number",
"description": "Internal minus external design temperature, in kelvin. The figure most of the fabric loss is worked out against."
},
"ventilationSharePercent": {
"type": "number"
}
},
"additionalProperties": false
},
"annotations": {
"title": "Room heat loss",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Estimate the annual AC electricity output of a UK solar photovoltaic system, in kWh, using the standard estimation method that MIS 3002 requires every MCS certified installer to use. The method is: annual output = kWp x Kk x SF, where Kk is read from the MCS irradiance dataset for the site's postcode zone, roof pitch and orientation, and SF is a shade factor between 0 and 1. Supply the postcode and the array's capacity in kWp, plus the roof's pitch in degrees from horizontal and its orientation in degrees away from due south in either direction, so that south is 0, south-east and south-west are both 45, east and west are both 90, and north is 180. The result carries the tabulated yield, the estimate, and what the same array would produce at the best pitch and orientation for that zone, so a roof that is merely good is not mistaken for a poor one. This covers the United Kingdom only; the dataset has no values for anywhere else. Method from MIS 3002. These calculators follow the published MCS methods, for understanding a system and checking a quotation. Anything that gets installed still needs a design and a site survey from a certified installer.
| Parameter | Type | Description |
|---|---|---|
| zone | string | MCS postcode zone code, for example '5E'. An alternative to 'postcode' when the zone is already known. |
| postcode | string | UK postcode of the installation, for example 'BS1 5TR'. Only the outward code matters. Give this or 'zone'. |
| capacityKwp * | number | Total installed capacity in kilowatts peak: the sum of the nameplate watts of every module, divided by 1000. Required. |
| inclination * | number | Pitch of the array in degrees from horizontal. A flat roof is 0 and a wall-mounted array is 90. Required. |
| orientation * | number | Degrees the array faces away from due south, in either direction, so due south is 0, south-east and south-west are 45, east and west are 90, and due north is 180. Required. |
| shadeFactor | number | Proportion of output left after shading, between 0.5 and 1. Use 1 for a clear horizon. Defaults to 1. |
{
"name": "solar_pv_output",
"title": "Solar PV annual output",
"description": "Estimate the annual AC electricity output of a UK solar photovoltaic system, in kWh,\nusing the standard estimation method that MIS 3002 requires every MCS certified installer to use.\n\nThe method is: annual output = kWp x Kk x SF, where Kk is read from the MCS irradiance dataset for\nthe site's postcode zone, roof pitch and orientation, and SF is a shade factor between 0 and 1.\n\nSupply the postcode and the array's capacity in kWp, plus the roof's pitch in degrees from horizontal\nand its orientation in degrees away from due south in either direction, so that south is 0, south-east\nand south-west are both 45, east and west are both 90, and north is 180.\n\nThe result carries the tabulated yield, the estimate, and what the same array would produce at the\nbest pitch and orientation for that zone, so a roof that is merely good is not mistaken for a poor one.\nThis covers the United Kingdom only; the dataset has no values for anywhere else.\n\nMethod from MIS 3002. These calculators follow the published MCS methods, for understanding a system and checking a quotation. Anything that gets installed still needs a design and a site survey from a certified installer.",
"inputSchema": {
"type": "object",
"required": [
"capacityKwp",
"orientation",
"inclination"
],
"properties": {
"zone": {
"type": "string",
"description": "MCS postcode zone code, for example '5E'. An alternative to 'postcode' when the zone is already known."
},
"postcode": {
"type": "string",
"description": "UK postcode of the installation, for example 'BS1 5TR'. Only the outward code matters. Give this or 'zone'."
},
"capacityKwp": {
"type": "number",
"description": "Total installed capacity in kilowatts peak: the sum of the nameplate watts of every module, divided by 1000. Required."
},
"inclination": {
"type": "number",
"description": "Pitch of the array in degrees from horizontal. A flat roof is 0 and a wall-mounted array is 90. Required."
},
"orientation": {
"type": "number",
"description": "Degrees the array faces away from due south, in either direction, so due south is 0, south-east and south-west are 45, east and west are 90, and due north is 180. Required."
},
"shadeFactor": {
"type": "number",
"description": "Proportion of output left after shading, between 0.5 and 1. Use 1 for a clear horizon. Defaults to 1."
}
},
"additionalProperties": false
},
"outputSchema": {
"type": "object",
"required": [
"zone",
"capacityKwp",
"orientation",
"inclination",
"shadeFactor",
"specificYieldKwhPerKwp",
"annualOutputKwh",
"unshadedOutputKwh",
"shadingLossKwh",
"bestCaseOrientation",
"bestCaseInclination",
"bestCaseAnnualKwh",
"percentOfBestCase",
"method",
"references",
"notes"
],
"properties": {
"zone": {
"type": "object",
"required": [
"code",
"city"
],
"properties": {
"city": {
"type": "string"
},
"code": {
"type": "string"
}
},
"additionalProperties": false
},
"notes": {
"type": [
"null",
"array"
],
"items": {
"type": "string"
}
},
"method": {
"type": "string"
},
"references": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"document",
"title",
"url"
],
"properties": {
"url": {
"type": "string"
},
"title": {
"type": "string"
},
"clause": {
"type": "string"
},
"document": {
"type": "string"
}
},
"additionalProperties": false
}
},
"capacityKwp": {
"type": "number"
},
"inclination": {
"type": "number",
"description": "Inclination after rounding to the nearest degree, as the method requires."
},
"orientation": {
"type": "number",
"description": "Orientation after rounding to the nearest five degrees, as the method requires."
},
"shadeFactor": {
"type": "number"
},
"postcodeUsed": {
"type": "string",
"description": "The postcode the zone was resolved from, when one was given."
},
"shadingLossKwh": {
"type": "number"
},
"annualOutputKwh": {
"type": "number",
"description": "The estimate: capacity multiplied by Kk multiplied by the shade factor."
},
"bestCaseAnnualKwh": {
"type": "number",
"description": "What this capacity would produce at the best pitch and orientation for the zone, unshaded. A yardstick, not a target: a roof faces where it faces."
},
"percentOfBestCase": {
"type": "number",
"description": "The estimate as a percentage of that best case."
},
"unshadedOutputKwh": {
"type": "number",
"description": "What the same array would produce with a clear horizon. Equals the estimate when the shade factor is 1."
},
"bestCaseInclination": {
"type": "number",
"description": "The pitch that yields most at this zone when facing due south."
},
"bestCaseOrientation": {
"type": "number",
"description": "The orientation that yields most at this pitch and zone. Almost always due south."
},
"specificYieldKwhPerKwp": {
"type": "number",
"description": "Kk: the kWh a single kWp produces in a year at this zone, pitch and orientation, before shading."
}
},
"additionalProperties": false
},
"annotations": {
"title": "Solar PV annual output",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Estimate what proportion of a domestic solar PV system's annual output is consumed in the house and what proportion is exported, using the lookup tables in MGD 003. The tables are not a model. They come from half-hourly monitoring of real British households by Loughborough University, with battery behaviour modelled on top, so they carry the real shape of domestic demand: a peak before the sun is up, another after it has gone, and a quiet middle of the day. Three things index them. The annual generation, which comes from the MIS 3002 output estimate. The household's annual consumption from a bill based on actual meter readings, which defaults to the British average of 3,500 kWh where it is unknown. And the weekday occupancy pattern, which is 'home_all_day', 'in_half_the_day' or 'out_all_day'; where the pattern is unknown MGD 003 says to use the middle one, and that is what an omitted value resolves to. Battery capacity is the USABLE capacity, which is smaller than the figure printed on the battery. Supplying import and export prices adds a value in pounds to the result. Note that self-consumption is not the same as independence from the grid, and the result reports both. Method from MGD 003. These calculators follow the published MCS methods, for understanding a system and checking a quotation. Anything that gets installed still needs a design and a site survey from a certified installer.
| Parameter | Type | Description |
|---|---|---|
| occupancy | string | Weekday occupancy pattern: 'home_all_day', 'in_half_the_day' or 'out_all_day'. Defaults to 'in_half_the_day', which is what MGD 003 says to use when the pattern is unknown. |
| batteryKwh | number | Usable capacity of any battery in kWh, which is smaller than the headline capacity. Omit or use 0 for no battery. |
| exportPricePerKwh | number | What the household is paid for a unit exported, in pounds. Optional. |
| importPricePerKwh | number | What the household pays for a unit of grid electricity, in pounds. Optional; supplying it adds a value to the result. |
| annualGenerationKwh * | number | Expected annual AC output of the PV system in kWh, as produced by the MIS 3002 estimation method. Required. |
| annualConsumptionKwh | number | The household's annual electricity consumption in kWh, from a bill based on actual meter readings. Defaults to 3500, which MGD 003 uses where the figure is unknown. |
{
"name": "solar_pv_self_consumption",
"title": "Solar PV self-consumption",
"description": "Estimate what proportion of a domestic solar PV system's annual output is consumed in\nthe house and what proportion is exported, using the lookup tables in MGD 003.\n\nThe tables are not a model. They come from half-hourly monitoring of real British households by\nLoughborough University, with battery behaviour modelled on top, so they carry the real shape of\ndomestic demand: a peak before the sun is up, another after it has gone, and a quiet middle of the day.\n\nThree things index them. The annual generation, which comes from the MIS 3002 output estimate. The\nhousehold's annual consumption from a bill based on actual meter readings, which defaults to the\nBritish average of 3,500 kWh where it is unknown. And the weekday occupancy pattern, which is\n'home_all_day', 'in_half_the_day' or 'out_all_day'; where the pattern is unknown MGD 003 says to use\nthe middle one, and that is what an omitted value resolves to.\n\nBattery capacity is the USABLE capacity, which is smaller than the figure printed on the battery.\nSupplying import and export prices adds a value in pounds to the result.\n\nNote that self-consumption is not the same as independence from the grid, and the result reports both.\n\nMethod from MGD 003. These calculators follow the published MCS methods, for understanding a system and checking a quotation. Anything that gets installed still needs a design and a site survey from a certified installer.",
"inputSchema": {
"type": "object",
"required": [
"annualGenerationKwh"
],
"properties": {
"occupancy": {
"type": "string",
"description": "Weekday occupancy pattern: 'home_all_day', 'in_half_the_day' or 'out_all_day'. Defaults to 'in_half_the_day', which is what MGD 003 says to use when the pattern is unknown."
},
"batteryKwh": {
"type": "number",
"description": "Usable capacity of any battery in kWh, which is smaller than the headline capacity. Omit or use 0 for no battery."
},
"exportPricePerKwh": {
"type": "number",
"description": "What the household is paid for a unit exported, in pounds. Optional."
},
"importPricePerKwh": {
"type": "number",
"description": "What the household pays for a unit of grid electricity, in pounds. Optional; supplying it adds a value to the result."
},
"annualGenerationKwh": {
"type": "number",
"description": "Expected annual AC output of the PV system in kWh, as produced by the MIS 3002 estimation method. Required."
},
"annualConsumptionKwh": {
"type": "number",
"description": "The household's annual electricity consumption in kWh, from a bill based on actual meter readings. Defaults to 3500, which MGD 003 uses where the figure is unknown."
}
},
"additionalProperties": false
},
"outputSchema": {
"type": "object",
"required": [
"occupancy",
"occupancyLabel",
"annualGenerationKwh",
"annualConsumptionKwh",
"consumptionAssumed",
"batteryKwh",
"selfConsumptionPercent",
"selfConsumedKwh",
"exportedKwh",
"importedKwh",
"gridIndependencePercent",
"withoutBatteryPercent",
"method",
"references",
"notes"
],
"properties": {
"notes": {
"type": [
"null",
"array"
],
"items": {
"type": "string"
}
},
"method": {
"type": "string"
},
"occupancy": {
"type": "string"
},
"batteryKwh": {
"type": "number"
},
"references": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"document",
"title",
"url"
],
"properties": {
"url": {
"type": "string"
},
"title": {
"type": "string"
},
"clause": {
"type": "string"
},
"document": {
"type": "string"
}
},
"additionalProperties": false
}
},
"annualValue": {
"type": "number",
"description": "The two added together."
},
"exportedKwh": {
"type": "number"
},
"importedKwh": {
"type": "number",
"description": "Units still bought from the grid over the year."
},
"batteryGainKwh": {
"type": "number",
"description": "Extra units kept in the house each year because of the battery."
},
"occupancyLabel": {
"type": "string"
},
"selfConsumedKwh": {
"type": "number"
},
"annualBillSaving": {
"type": "number",
"description": "Value of the units not bought, in pounds. Only present when an import price was given."
},
"annualExportIncome": {
"type": "number",
"description": "Value of the units exported, in pounds. Only present when an export price was given."
},
"consumptionAssumed": {
"type": "boolean",
"description": "True when the 3500 kWh default stood in for a figure the caller did not give."
},
"annualGenerationKwh": {
"type": "number"
},
"annualConsumptionKwh": {
"type": "number"
},
"withoutBatteryPercent": {
"type": "number",
"description": "What the same system would self-consume with no battery."
},
"selfConsumptionPercent": {
"type": "number",
"description": "Proportion of generation used in the home instead of exported."
},
"gridIndependencePercent": {
"type": "number",
"description": "Proportion of the household's own consumption met by the system instead of by the grid. Different from self-consumption, and usually smaller."
}
},
"additionalProperties": false
},
"annotations": {
"title": "Solar PV self-consumption",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Convert a completed MCS sunpath shading assessment into a shade factor, using the procedure in MGD 005. The MCS sunpath chart is divided into 84 segments, each worth one per cent of the year's useful irradiance. An assessor stands at the middle of where the array will go, plots what blocks the horizon onto the chart, and counts the segments covered. This tool takes that count and returns 1 minus the loss, which is the SF term in the MIS 3002 output estimate. Objects within ten metres of the array are near shading and are assessed separately, from each affected part of the array, not from its middle. They can be listed here for the record, but MGD 005 is explicit that near shading has a considerable effect and should be avoided. This tool does not perform the assessment. It does the arithmetic on an assessment somebody made. Method from MGD 005. These calculators follow the published MCS methods, for understanding a system and checking a quotation. Anything that gets installed still needs a design and a site survey from a certified installer.
| Parameter | Type | Description |
|---|---|---|
| segments * | integer | Number of segments on the MCS sunpath chart that the obstruction touches, from 0 to 84. Each segment is worth one per cent of the year's irradiance. |
| nearObjects | ["null","array"] | Objects within ten metres of the middle of the array, each assessed from its own position on the array. Optional. |
{
"name": "solar_pv_shading",
"title": "Solar PV shade factor",
"description": "Convert a completed MCS sunpath shading assessment into a shade factor, using the\nprocedure in MGD 005.\n\nThe MCS sunpath chart is divided into 84 segments, each worth one per cent of the year's useful\nirradiance. An assessor stands at the middle of where the array will go, plots what blocks the\nhorizon onto the chart, and counts the segments covered. This tool takes that count and returns\n1 minus the loss, which is the SF term in the MIS 3002 output estimate.\n\nObjects within ten metres of the array are near shading and are assessed separately, from each\naffected part of the array, not from its middle. They can be listed here for the record, but\nMGD 005 is explicit that near shading has a considerable effect and should be avoided.\n\nThis tool does not perform the assessment. It does the arithmetic on an assessment somebody made.\n\nMethod from MGD 005. These calculators follow the published MCS methods, for understanding a system and checking a quotation. Anything that gets installed still needs a design and a site survey from a certified installer.",
"inputSchema": {
"type": "object",
"required": [
"segments"
],
"properties": {
"segments": {
"type": "integer",
"description": "Number of segments on the MCS sunpath chart that the obstruction touches, from 0 to 84. Each segment is worth one per cent of the year's irradiance."
},
"nearObjects": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"segments",
"modulesAffected"
],
"properties": {
"segments": {
"type": "integer",
"description": "Segments the object touches on the sunpath chart, from 0 to 84."
},
"description": {
"type": "string",
"description": "What the object is, for example 'chimney' or 'television aerial'."
},
"modulesAffected": {
"type": "integer",
"description": "How many modules in the array this object shades."
}
},
"additionalProperties": false
},
"description": "Objects within ten metres of the middle of the array, each assessed from its own position on the array. Optional."
}
},
"additionalProperties": false
},
"outputSchema": {
"type": "object",
"required": [
"segments",
"shadingLoss",
"shadeFactor",
"shadingLossPercent",
"verdict",
"severity",
"method",
"references",
"notes"
],
"properties": {
"notes": {
"type": [
"null",
"array"
],
"items": {
"type": "string"
}
},
"method": {
"type": "string"
},
"verdict": {
"type": "string"
},
"segments": {
"type": "integer"
},
"severity": {
"type": "string",
"description": "One of 'none', 'slight', 'moderate' or 'severe'."
},
"references": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"document",
"title",
"url"
],
"properties": {
"url": {
"type": "string"
},
"title": {
"type": "string"
},
"clause": {
"type": "string"
},
"document": {
"type": "string"
}
},
"additionalProperties": false
}
},
"nearObjects": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"segments",
"modulesAffected",
"lossPercent"
],
"properties": {
"segments": {
"type": "integer"
},
"description": {
"type": "string"
},
"lossPercent": {
"type": "number"
},
"modulesAffected": {
"type": "integer"
}
},
"additionalProperties": false
}
},
"shadeFactor": {
"type": "number",
"description": "The multiplier to apply to an unshaded output estimate: 1 minus the loss."
},
"shadingLoss": {
"type": "number",
"description": "Proportion of the year's irradiance blocked, as a decimal."
},
"shadingLossPercent": {
"type": "number"
},
"totalModulesAffected": {
"type": "integer"
}
},
"additionalProperties": false
},
"annotations": {
"title": "Solar PV shade factor",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Work out the solar PV system a UK home needs: the capacity in kWp, the number of panels, the battery to go with it, and what it would do to the electricity bill. This runs the MCS arithmetic backwards. The other solar calculators here each answer one question about a system somebody has already specified. This one starts from what a household uses and arrives at the system that covers it, which is the question a householder actually has. The chain is short and every link is published. Annual consumption sets the generation the array has to make. The MCS irradiance dataset behind MIS 3002 says what one kWp makes on that roof, which gives a capacity. Capacity divided by panel size gives a panel count, rounded up, because panels come whole. The MGD 003 tables then say how much of that generation the household will use and how much it will export. Only the postcode and the roof direction are required. Direction is a compass point, not an angle: 'S', 'SE', 'SW', 'E', 'W', 'NE', 'NW' or 'N'. Give the annual consumption from a bill if it is known, since the 3,500 kWh default is only the British average. Shading can be described in words instead of measured, and a roof area caps the panel count where the roof is the constraint. No cost is assumed. Installed prices vary far too much between houses to guess at, so a payback figure appears only when a cost from a real quotation is supplied. Use this to size a system or to sanity-check a quotation. Use 'solar_pv_output' instead when the capacity is already known and the question is only what it will generate. Method from MIS 3002. These calculators follow the published MCS methods, for understanding a system and checking a quotation. Anything that gets installed still needs a design and a site survey from a certified installer.
| Parameter | Type | Description |
|---|---|---|
| shading | string | How much shading the roof has, in words: 'none', 'light', 'moderate' or 'heavy'. Defaults to 'none'. Use 'shadeFactor' instead if a proper MGD 005 assessment has been done. |
| postcode * | string | UK postcode of the property, for example 'BS1 5TR'. Only the outward code matters. Required. |
| direction * | string | Compass point the roof faces: 'S', 'SE', 'SW', 'E', 'W', 'NE', 'NW' or 'N'. Required. |
| occupancy | string | Weekday occupancy: 'home_all_day', 'in_half_the_day' or 'out_all_day'. Decides how much of the generation is used at home instead of exported. Defaults to 'in_half_the_day'. |
| panelWatts | number | Nameplate rating of a single panel in watts. Defaults to 440, which is typical of a current domestic module. |
| roofAreaM2 | number | Shade-free roof area available for panels, in square metres. Optional; when given it caps the number of panels. |
| inclination | number | Roof pitch in degrees from horizontal. Defaults to 35, which is typical of a British pitched roof. A flat roof is 0. |
| shadeFactor | number | A measured shade factor between 0.5 and 1 from an MGD 005 assessment. Overrides 'shading' when given. |
| installedCost | number | The installed cost of the system in pounds, from a quotation. Optional; supplying it gives a payback period. No cost is assumed if it is left out, because prices vary too much to guess at. |
| includeBattery | boolean | Whether to size a battery alongside the panels. Defaults to false. |
| batteryModuleKwh | number | Nominal capacity of one battery module in kWh. Batteries are sold in whole modules, so the answer rounds up to one. Defaults to 5. |
| exportPricePerKwh | number | What the household is paid for a unit exported, in pounds. Optional. |
| annualConsumptionKwh | number | The household's electricity use in kWh a year, from a bill. Defaults to 3500, which is the British average and the figure MGD 003 falls back on, but a real bill sharpens the answer considerably. |
| electricityPricePerKwh | number | What the household pays for a unit, in pounds. Optional; supplying it puts a value on the answer. |
{
"name": "solar_pv_system_size",
"title": "What size solar system do I need?",
"description": "Work out the solar PV system a UK home needs: the capacity in kWp, the number of\npanels, the battery to go with it, and what it would do to the electricity bill.\n\nThis runs the MCS arithmetic backwards. The other solar calculators here each answer one question\nabout a system somebody has already specified. This one starts from what a household uses and\narrives at the system that covers it, which is the question a householder actually has.\n\nThe chain is short and every link is published. Annual consumption sets the generation the array has\nto make. The MCS irradiance dataset behind MIS 3002 says what one kWp makes on that roof, which gives\na capacity. Capacity divided by panel size gives a panel count, rounded up, because panels come whole.\nThe MGD 003 tables then say how much of that generation the household will use and how much it will export.\n\nOnly the postcode and the roof direction are required. Direction is a compass point, not an angle:\n'S', 'SE', 'SW', 'E', 'W', 'NE', 'NW' or 'N'. Give the annual consumption from a bill if it is known,\nsince the 3,500 kWh default is only the British average. Shading can be described in words instead of\nmeasured, and a roof area caps the panel count where the roof is the constraint.\n\nNo cost is assumed. Installed prices vary far too much between houses to guess at, so a payback figure\nappears only when a cost from a real quotation is supplied.\n\nUse this to size a system or to sanity-check a quotation. Use 'solar_pv_output' instead when the\ncapacity is already known and the question is only what it will generate.\n\nMethod from MIS 3002. These calculators follow the published MCS methods, for understanding a system and checking a quotation. Anything that gets installed still needs a design and a site survey from a certified installer.",
"inputSchema": {
"type": "object",
"required": [
"postcode",
"direction"
],
"properties": {
"shading": {
"type": "string",
"description": "How much shading the roof has, in words: 'none', 'light', 'moderate' or 'heavy'. Defaults to 'none'. Use 'shadeFactor' instead if a proper MGD 005 assessment has been done."
},
"postcode": {
"type": "string",
"description": "UK postcode of the property, for example 'BS1 5TR'. Only the outward code matters. Required."
},
"direction": {
"type": "string",
"description": "Compass point the roof faces: 'S', 'SE', 'SW', 'E', 'W', 'NE', 'NW' or 'N'. Required."
},
"occupancy": {
"type": "string",
"description": "Weekday occupancy: 'home_all_day', 'in_half_the_day' or 'out_all_day'. Decides how much of the generation is used at home instead of exported. Defaults to 'in_half_the_day'."
},
"panelWatts": {
"type": "number",
"description": "Nameplate rating of a single panel in watts. Defaults to 440, which is typical of a current domestic module."
},
"roofAreaM2": {
"type": "number",
"description": "Shade-free roof area available for panels, in square metres. Optional; when given it caps the number of panels."
},
"inclination": {
"type": "number",
"description": "Roof pitch in degrees from horizontal. Defaults to 35, which is typical of a British pitched roof. A flat roof is 0."
},
"shadeFactor": {
"type": "number",
"description": "A measured shade factor between 0.5 and 1 from an MGD 005 assessment. Overrides 'shading' when given."
},
"installedCost": {
"type": "number",
"description": "The installed cost of the system in pounds, from a quotation. Optional; supplying it gives a payback period. No cost is assumed if it is left out, because prices vary too much to guess at."
},
"includeBattery": {
"type": "boolean",
"description": "Whether to size a battery alongside the panels. Defaults to false."
},
"batteryModuleKwh": {
"type": "number",
"description": "Nominal capacity of one battery module in kWh. Batteries are sold in whole modules, so the answer rounds up to one. Defaults to 5."
},
"exportPricePerKwh": {
"type": "number",
"description": "What the household is paid for a unit exported, in pounds. Optional."
},
"annualConsumptionKwh": {
"type": "number",
"description": "The household's electricity use in kWh a year, from a bill. Defaults to 3500, which is the British average and the figure MGD 003 falls back on, but a real bill sharpens the answer considerably."
},
"electricityPricePerKwh": {
"type": "number",
"description": "What the household pays for a unit, in pounds. Optional; supplying it puts a value on the answer."
}
},
"additionalProperties": false
},
"outputSchema": {
"type": "object",
"required": [
"zone",
"postcodeUsed",
"direction",
"inclination",
"shadeFactor",
"annualConsumptionKwh",
"consumptionAssumed",
"capacityKwp",
"panels",
"panelWatts",
"idealCapacityKwp",
"roofAreaNeededM2",
"roofLimited",
"specificYieldKwhPerKwp",
"annualGenerationKwh",
"selfConsumedKwh",
"exportedKwh",
"importedKwh",
"selfConsumptionPercent",
"gridIndependencePercent",
"occupancyLabel",
"generationAsPercentOfUse",
"method",
"references",
"notes"
],
"properties": {
"zone": {
"type": "object",
"required": [
"code",
"city"
],
"properties": {
"city": {
"type": "string"
},
"code": {
"type": "string"
}
},
"additionalProperties": false
},
"notes": {
"type": [
"null",
"array"
],
"items": {
"type": "string"
}
},
"method": {
"type": "string"
},
"panels": {
"type": "integer"
},
"battery": {
"type": [
"null",
"object"
],
"required": [
"modules",
"moduleKwh",
"nominalKwh",
"usableKwh",
"averageDailyConsumptionKwh",
"selfConsumptionGainPercent",
"extraKwhKeptAtHome"
],
"properties": {
"modules": {
"type": "integer"
},
"moduleKwh": {
"type": "number"
},
"usableKwh": {
"type": "number",
"description": "What the battery will actually give back, which is what MGD 003 is indexed on."
},
"nominalKwh": {
"type": "number"
},
"extraKwhKeptAtHome": {
"type": "number"
},
"averageDailyConsumptionKwh": {
"type": "number"
},
"selfConsumptionGainPercent": {
"type": "number",
"description": "Percentage points of self-consumption the battery adds."
}
},
"additionalProperties": false
},
"shading": {
"type": [
"null",
"object"
],
"required": [
"key",
"label",
"sunpathSegments",
"shadeFactor",
"description"
],
"properties": {
"key": {
"type": "string"
},
"label": {
"type": "string"
},
"description": {
"type": "string"
},
"shadeFactor": {
"type": "number"
},
"sunpathSegments": {
"type": "integer",
"description": "The equivalent count on the MGD 005 sunpath chart, out of 84."
}
},
"description": "The shading description used, when one was chosen in place of a measured factor.",
"additionalProperties": false
},
"direction": {
"type": "object",
"required": [
"key",
"label",
"orientation"
],
"properties": {
"key": {
"type": "string"
},
"label": {
"type": "string"
},
"orientation": {
"type": "number",
"description": "Degrees from due south, as MIS 3002 measures it."
}
},
"additionalProperties": false
},
"panelWatts": {
"type": "number"
},
"references": {
"type": [
"null",
"array"
],
"items": {
"type": "object",
"required": [
"document",
"title",
"url"
],
"properties": {
"url": {
"type": "string"
},
"title": {
"type": "string"
},
"clause": {
"type": "string"
},
"document": {
"type": "string"
}
},
"additionalProperties": false
}
},
"capacityKwp": {
"type": "number",
"description": "The installed capacity: the panel count multiplied by the panel rating."
},
"exportedKwh": {
"type": "number"
},
"importedKwh": {
"type": "number",
"description": "Units still bought from the grid over a year."
},
"inclination": {
"type": "number"
},
"roofLimited": {
"type": "boolean",
"description": "True when the roof area given, not consumption, set the size."
},
"shadeFactor": {
"type": "number"
},
"paybackYears": {
"type": "number",
"description": "Installed cost divided by the annual benefit. Only present when a cost was supplied."
},
"postcodeUsed": {
"type": "string"
},
"annualBenefit": {
"type": "number",
"description": "Bill saving plus export income."
},
"installedCost": {
"type": "number"
},
"newAnnualCost": {
"type": "number"
},
"occupancyLabel": {
"type": "string"
},
"selfConsumedKwh": {
"type": "number"
},
"annualBillSaving": {
"type": "number"
},
"idealCapacityKwp": {
"type": "number",
"description": "The capacity that would exactly cover a year of consumption, before rounding up to whole panels."
},
"roofAreaNeededM2": {
"type": "number"
},
"currentAnnualCost": {
"type": "number"
},
"annualExportIncome": {
"type": "number"
},
"consumptionAssumed": {
"type": "boolean",
"description": "True when the 3500 kWh default stood in for a figure the caller did not give."
},
"annualGenerationKwh": {
"type": "number"
},
"annualConsumptionKwh": {
"type": "number"
},
"selfConsumptionPercent": {
"type": "number"
},
"specificYieldKwhPerKwp": {
"type": "number",
"description": "Kk: the kWh a kWp produces in a year at this zone, pitch and orientation."
},
"gridIndependencePercent": {
"type": "number",
"description": "The share of the household's own use met by the system."
},
"generationAsPercentOfUse": {
"type": "number",
"description": "Annual generation as a percentage of annual consumption. Above 100 means the system makes more over a year than the house uses, though not at the same times."
}
},
"additionalProperties": false
},
"annotations": {
"title": "What size solar system do I need?",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Ampworth covers homes in the United Kingdom only. Its methods come from the published MCS standards, and the network connection route from the ENA's G98 and G99. Don't apply them to another country: say the tools don't cover it. Every answer is for understanding a system or checking a quotation, not a design. Say that an installation still needs a survey and a design from a certified installer. Ampworth recommends no installer; to find one, point to https://mcscertified.com/find-an-installer/. Ask for a required input rather than guessing it, especially a postcode, a roof direction or a year of energy use. When an answer relies on a default, say which one. Pass on the figures, the standard and the warnings each result returns. Calculators: - When someone asks what system they need, start with solar_pv_system_size or heat_pump_size. Use the single-method tools to check a figure they already have. - To check a quoted heat pump, give its output to heat_pump_size as quotedHeatPumpKw. - When a field must be one of a fixed set, such as a design location, room type or fuel, call list_calculators for the values. - Prices are in pounds per unit (0.27, not 27p), and efficiencies and fractions are decimals (0.85, not 85%).
Names, descriptions and schemas were written by the server and are shown as data.
Shared addresses on big platforms (Cloudflare, Vercel and the like) put unrelated servers together; those are marked shared_infrastructure. A match is a pivot, not a link between operators.