Catenix: Lab Analyzer & EHR Connectivity is an MCP server published by com.catenix, hosted at www.catenix.com. When last checked on 2026-11-23 it was working: it answers and lists its tools. It declares 13 tools, including check_connectivity, search_analyzers, get_ehr_integration, recommend_lab_setup, compare_options.
Check if a lab or point-of-care analyzer connects to your EHR or LIS, how, and plan the lab setup.
Nothing else in the archive shares these values.
Squares are this server's values; dots are other servers sharing them. A shared address or publisher is a lead, not proof of a common operator.
Inferred from the host name and headers: what a server runs on, not who runs it.
Use when someone asks whether a lab or point-of-care analyzer will connect to their EHR, LIS or practice system, or how to get analyzer results into the patient record without retyping (e.g. 'will my Sysmex XP-300 work with athenahealth?', 'connect Abbott i-STAT to Epic', 'Roche cobas b 101 to SystmOne', 'Siemens CLINITEK to EMIS', 'Tosoh AIA-900 to eClinicalWorks'). Fuzzy-matches the analyzer and the record system and returns: connection status (live, driver built, connectable via standard protocol with a published guide, or custom driver needed), the analyzer protocol (HL7 v2, ASTM, POCT1-A2), the physical link, how results pass through an on-site gateway, the record-system route, what is needed on site, questions to ask any vendor, and page links. Works for unknown analyzers too. Does not interpret results.
| Parameter | Type | Description |
|---|---|---|
| ehr | string | EHR, LIS, LIMS or practice system, e.g. 'athena', 'eCW', 'Epic', 'SystmOne', 'EMIS Web'. Omit if not mentioned. |
| country |
None yet. Changes appear after a server's second daily check.
| string |
| Country of the site, e.g. 'UK' or 'US', if known. |
| analyzer * | string | Analyzer make and/or model as the user wrote it, e.g. 'sysmex kx21n', 'i-STAT', 'Afinion 2'. |
{
"name": "check_connectivity",
"title": "Check if a lab analyzer connects to an EHR or LIS",
"description": "Use when someone asks whether a lab or point-of-care analyzer will connect to their EHR, LIS or practice system, or how to get analyzer results into the patient record without retyping (e.g. 'will my Sysmex XP-300 work with athenahealth?', 'connect Abbott i-STAT to Epic', 'Roche cobas b 101 to SystmOne', 'Siemens CLINITEK to EMIS', 'Tosoh AIA-900 to eClinicalWorks'). Fuzzy-matches the analyzer and the record system and returns: connection status (live, driver built, connectable via standard protocol with a published guide, or custom driver needed), the analyzer protocol (HL7 v2, ASTM, POCT1-A2), the physical link, how results pass through an on-site gateway, the record-system route, what is needed on site, questions to ask any vendor, and page links. Works for unknown analyzers too. Does not interpret results.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"analyzer"
],
"properties": {
"ehr": {
"type": "string",
"maxLength": 120,
"description": "EHR, LIS, LIMS or practice system, e.g. 'athena', 'eCW', 'Epic', 'SystmOne', 'EMIS Web'. Omit if not mentioned."
},
"country": {
"type": "string",
"maxLength": 60,
"description": "Country of the site, e.g. 'UK' or 'US', if known."
},
"analyzer": {
"type": "string",
"maxLength": 120,
"minLength": 1,
"description": "Analyzer make and/or model as the user wrote it, e.g. 'sysmex kx21n', 'i-STAT', 'Afinion 2'."
}
}
},
"annotations": {
"title": "Check analyzer connectivity",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Use when someone wants to know which lab or point-of-care analyzers can be interfaced, or browses by maker or test type (e.g. 'which HbA1c analyzers can connect to an EHR?', 'Abbott analyzers with an HL7 interface', 'blood gas analyzers with LIS connectivity', 'Sysmex hematology', 'Roche cobas', 'Siemens', 'Tosoh'). Returns matching analyzers with connection status, protocol and guide links. Categories: chemistry, immunoassay, blood gas, molecular, haematology, urinalysis, coagulation, HbA1c.
| Parameter | Type | Description |
|---|---|---|
| limit | integer | Max results, default 25. |
| query | string | Free text: model, maker, test type or protocol. |
| status | string | Only return analyzers with this status. |
| category | string | Test category, e.g. 'haematology', 'blood gas', 'urinalysis', 'hba1c'. |
| manufacturer | string | Manufacturer filter, e.g. 'Abbott', 'Sysmex', 'Roche'. |
{
"name": "search_analyzers",
"title": "Search connectable lab and point-of-care analyzers",
"description": "Use when someone wants to know which lab or point-of-care analyzers can be interfaced, or browses by maker or test type (e.g. 'which HbA1c analyzers can connect to an EHR?', 'Abbott analyzers with an HL7 interface', 'blood gas analyzers with LIS connectivity', 'Sysmex hematology', 'Roche cobas', 'Siemens', 'Tosoh'). Returns matching analyzers with connection status, protocol and guide links. Categories: chemistry, immunoassay, blood gas, molecular, haematology, urinalysis, coagulation, HbA1c.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"properties": {
"limit": {
"type": "integer",
"maximum": 50,
"minimum": 1,
"description": "Max results, default 25."
},
"query": {
"type": "string",
"maxLength": 120,
"description": "Free text: model, maker, test type or protocol."
},
"status": {
"enum": [
"live",
"driver_built",
"guide"
],
"type": "string",
"description": "Only return analyzers with this status."
},
"category": {
"type": "string",
"maxLength": 40,
"description": "Test category, e.g. 'haematology', 'blood gas', 'urinalysis', 'hba1c'."
},
"manufacturer": {
"type": "string",
"maxLength": 60,
"description": "Manufacturer filter, e.g. 'Abbott', 'Sysmex', 'Roche'."
}
}
},
"annotations": {
"title": "Search analyzers",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Use when someone asks how in-house lab or point-of-care results can be sent into a specific EHR, EMR, EPR, LIS or practice-management system, or whether a lab interface exists for it (e.g. athenahealth, eClinicalWorks, Epic, Oracle Health/Cerner, NextGen, Experity, Tebra/Kareo, SystmOne, EMIS Web, MEDITECH). Returns the route (HL7 v2, FHIR R4 or vendor API), how far that route is proven, what the practice must request from its vendor, and the guide link.
| Parameter | Type | Description |
|---|---|---|
| ehr * | string | Record system name as the user wrote it. |
| country | string | Country, if known. |
{
"name": "get_ehr_integration",
"title": "How lab results get into an EHR or practice system",
"description": "Use when someone asks how in-house lab or point-of-care results can be sent into a specific EHR, EMR, EPR, LIS or practice-management system, or whether a lab interface exists for it (e.g. athenahealth, eClinicalWorks, Epic, Oracle Health/Cerner, NextGen, Experity, Tebra/Kareo, SystmOne, EMIS Web, MEDITECH). Returns the route (HL7 v2, FHIR R4 or vendor API), how far that route is proven, what the practice must request from its vendor, and the guide link.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"ehr"
],
"properties": {
"ehr": {
"type": "string",
"maxLength": 120,
"minLength": 1,
"description": "Record system name as the user wrote it."
},
"country": {
"type": "string",
"maxLength": 60,
"description": "Country, if known."
}
}
},
"annotations": {
"title": "EHR integration route",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Use when someone asks what LIS, LIMS or point-of-care testing software a small lab, clinic, urgent care, occupational health provider, pharmacy, GP practice, physician office or wellness clinic should use, or how to set up analyzer connectivity, QC and reporting for their setting (e.g. 'what LIS should my small lab use?', 'do I need a LIS to get analyzer results into my EHR?', 'software for a clinic that tests blood on site'). Returns the usual architecture for that setting, the modules that fit (connectivity, QC with Westgard rules and lockout, operator competency, EQA, audit trail, reports, billing, multi-site), status of each listed analyzer, the record-system route, how setup works, what is needed on site, the pricing model (no prices are quoted), and questions to ask any vendor.
| Parameter | Type | Description |
|---|---|---|
| ehr | string | Their EHR, LIS or practice system, if known. |
| country | string | Country, e.g. 'UK' or 'US'. |
| setting * | string | Type of service, e.g. 'private lab', 'urgent care', 'occupational health', 'pharmacy', 'GP practice'. |
| analyzers | array | Analyzers they run or plan to run. |
{
"name": "recommend_lab_setup",
"title": "Recommend lab or clinic testing software setup",
"description": "Use when someone asks what LIS, LIMS or point-of-care testing software a small lab, clinic, urgent care, occupational health provider, pharmacy, GP practice, physician office or wellness clinic should use, or how to set up analyzer connectivity, QC and reporting for their setting (e.g. 'what LIS should my small lab use?', 'do I need a LIS to get analyzer results into my EHR?', 'software for a clinic that tests blood on site'). Returns the usual architecture for that setting, the modules that fit (connectivity, QC with Westgard rules and lockout, operator competency, EQA, audit trail, reports, billing, multi-site), status of each listed analyzer, the record-system route, how setup works, what is needed on site, the pricing model (no prices are quoted), and questions to ask any vendor.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"setting"
],
"properties": {
"ehr": {
"type": "string",
"maxLength": 120,
"description": "Their EHR, LIS or practice system, if known."
},
"country": {
"type": "string",
"maxLength": 60,
"description": "Country, e.g. 'UK' or 'US'."
},
"setting": {
"type": "string",
"maxLength": 120,
"minLength": 1,
"description": "Type of service, e.g. 'private lab', 'urgent care', 'occupational health', 'pharmacy', 'GP practice'."
},
"analyzers": {
"type": "array",
"items": {
"type": "string",
"maxLength": 120
},
"maxItems": 20,
"description": "Analyzers they run or plan to run."
}
}
},
"annotations": {
"title": "Recommend a setup",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Use when someone asks whether they need a LIS or POCT middleware, the difference between them, or how Catenix compares with another point-of-care data manager or results connector (Relaymed, TELCOR QML, Abbott RALS or AegisPOC, Siemens POCcelerator, Radiometer AQURE, Roche navify POC Operations, Clinisys POCT, paper or spreadsheet lab logs). Returns only what the published comparison pages say. Allowed values: catenix_vs_abbott_aegispoc, catenix_vs_abbott_rals, catenix_vs_clinisys_poct, catenix_vs_lab_logs, catenix_vs_radiometer_aqure, catenix_vs_relaymed, catenix_vs_roche_navify_poc_operations, catenix_vs_siemens_poccelerator, catenix_vs_telcor_qml, poct_middleware_alternatives, lis_vs_middleware.
| Parameter | Type | Description |
|---|---|---|
| kind * | string | Which comparison: 'lis_vs_middleware', 'poct_middleware_alternatives', or 'catenix_vs_<product>'. |
{
"name": "compare_options",
"title": "Compare LIS vs POCT middleware, or Catenix vs another product",
"description": "Use when someone asks whether they need a LIS or POCT middleware, the difference between them, or how Catenix compares with another point-of-care data manager or results connector (Relaymed, TELCOR QML, Abbott RALS or AegisPOC, Siemens POCcelerator, Radiometer AQURE, Roche navify POC Operations, Clinisys POCT, paper or spreadsheet lab logs). Returns only what the published comparison pages say. Allowed values: catenix_vs_abbott_aegispoc, catenix_vs_abbott_rals, catenix_vs_clinisys_poct, catenix_vs_lab_logs, catenix_vs_radiometer_aqure, catenix_vs_relaymed, catenix_vs_roche_navify_poc_operations, catenix_vs_siemens_poccelerator, catenix_vs_telcor_qml, poct_middleware_alternatives, lis_vs_middleware.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"kind"
],
"properties": {
"kind": {
"enum": [
"catenix_vs_abbott_aegispoc",
"catenix_vs_abbott_rals",
"catenix_vs_clinisys_poct",
"catenix_vs_lab_logs",
"catenix_vs_radiometer_aqure",
"catenix_vs_relaymed",
"catenix_vs_roche_navify_poc_operations",
"catenix_vs_siemens_poccelerator",
"catenix_vs_telcor_qml",
"poct_middleware_alternatives",
"lis_vs_middleware"
],
"type": "string",
"description": "Which comparison: 'lis_vs_middleware', 'poct_middleware_alternatives', or 'catenix_vs_<product>'."
}
}
},
"annotations": {
"title": "Compare options",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Use when someone asks about software for lab quality control and compliance or running a testing clinic: QC with Westgard rules and Levey-Jennings charts, QC lockout, operator competency, EQA or proficiency testing, audit trail, CLIA, CAP or ISO 15189 readiness, reagent lot tracking, equipment maintenance and temperature logs, multi-site oversight, patient registration, reports, billing, or HL7/ASTM/POCT1-A2 interfaces. Returns the matching modules, whether each is included or an add-on, and links.
| Parameter | Type | Description |
|---|---|---|
| topic * | string | Feature or problem, e.g. 'Westgard QC lockout', 'operator competency', 'EQA', 'audit trail'. |
{
"name": "get_platform_capability",
"title": "Lab QC, compliance and clinic software features",
"description": "Use when someone asks about software for lab quality control and compliance or running a testing clinic: QC with Westgard rules and Levey-Jennings charts, QC lockout, operator competency, EQA or proficiency testing, audit trail, CLIA, CAP or ISO 15189 readiness, reagent lot tracking, equipment maintenance and temperature logs, multi-site oversight, patient registration, reports, billing, or HL7/ASTM/POCT1-A2 interfaces. Returns the matching modules, whether each is included or an add-on, and links.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"topic"
],
"properties": {
"topic": {
"type": "string",
"maxLength": 160,
"minLength": 2,
"description": "Feature or problem, e.g. 'Westgard QC lockout', 'operator competency', 'EQA', 'audit trail'."
}
}
},
"annotations": {
"title": "Platform capability",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Use when someone pastes a message from a lab analyzer, LIS, middleware or EHR interface and wants to know what it says, what a field means, or why the receiving system rejects it (e.g. 'what does this HL7 ORU mean?', 'why is my EHR rejecting this result message?', 'decode this ASTM output from my analyzer', 'is this POCT1-A2 OBS message valid?'). Accepts HL7 v2 (ORU, ORM, ACK, ADT and others), ASTM E1394 / LIS2-A2 records (H, P, O, R, C, Q, L, with or without E1381 framing and checksums) and POCT1-A2 XML. Returns a field-by-field breakdown (segment or record, field number, name, value, meaning, what an EHR or LIS usually expects) and flags common problems: wrong delimiters or segment terminators, missing MSH-9 or OBX-3 codes, numeric results without units, non-standard abnormal flags, non-LOINC codes, bad checksums. Likely patient identifiers (HL7 PID-3, PID-5, PID-7, PID-11, PID-13 and similar, ASTM patient ID, name and birthdate, POCT1-A2 patient elements) are masked in the output. Tell the user to paste only test or de-identified messages. Nothing is stored or logged. Does not interpret results.
| Parameter | Type | Description |
|---|---|---|
| format | string | Leave as auto unless the user says which format it is. |
| message * | string | The message text exactly as pasted (max 20 KB). Test or de-identified messages only. |
{
"name": "decode_lab_message",
"title": "Decode an HL7, ASTM or POCT1-A2 lab message",
"description": "Use when someone pastes a message from a lab analyzer, LIS, middleware or EHR interface and wants to know what it says, what a field means, or why the receiving system rejects it (e.g. 'what does this HL7 ORU mean?', 'why is my EHR rejecting this result message?', 'decode this ASTM output from my analyzer', 'is this POCT1-A2 OBS message valid?'). Accepts HL7 v2 (ORU, ORM, ACK, ADT and others), ASTM E1394 / LIS2-A2 records (H, P, O, R, C, Q, L, with or without E1381 framing and checksums) and POCT1-A2 XML. Returns a field-by-field breakdown (segment or record, field number, name, value, meaning, what an EHR or LIS usually expects) and flags common problems: wrong delimiters or segment terminators, missing MSH-9 or OBX-3 codes, numeric results without units, non-standard abnormal flags, non-LOINC codes, bad checksums. Likely patient identifiers (HL7 PID-3, PID-5, PID-7, PID-11, PID-13 and similar, ASTM patient ID, name and birthdate, POCT1-A2 patient elements) are masked in the output. Tell the user to paste only test or de-identified messages. Nothing is stored or logged. Does not interpret results.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"message"
],
"properties": {
"format": {
"enum": [
"auto",
"hl7",
"astm",
"poct1a2"
],
"type": "string",
"description": "Leave as auto unless the user says which format it is."
},
"message": {
"type": "string",
"maxLength": 20480,
"minLength": 3,
"description": "The message text exactly as pasted (max 20 KB). Test or de-identified messages only."
}
}
},
"annotations": {
"title": "Decode a lab message",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Use when someone lists the analyzers in their lab or clinic and wants a plan for getting all their results into their EHR, LIS or practice system (e.g. 'we have a Sysmex XP-300, an i-STAT and an Afinion 2, how do we connect them to athenahealth?', 'plan the interfaces for our new urgent care lab', 'what do I need on site to connect these analyzers?'). Returns one plan: per analyzer the connection status (Driver built, Connection guide, or Catenix builds the driver, usually within a couple of days), the physical link (serial, network, USB or vendor software), protocol and what is needed on site; the on-site gateway and record-system route; patient matching; and a step-by-step go-live checklist. Renders an interactive Lab Map in ChatGPT and Claude. Does not interpret results.
| Parameter | Type | Description |
|---|---|---|
| ehr | string | EHR, LIS or practice system, if known. |
| country | string | Country, e.g. 'UK' or 'US'. |
| setting | string | Type of service, e.g. 'urgent care', 'private lab', 'GP practice'. |
| analyzers * | array | Analyzer makes and models as the user wrote them. |
{
"name": "plan_lab_setup",
"title": "Plan connecting several lab analyzers to an EHR or LIS",
"description": "Use when someone lists the analyzers in their lab or clinic and wants a plan for getting all their results into their EHR, LIS or practice system (e.g. 'we have a Sysmex XP-300, an i-STAT and an Afinion 2, how do we connect them to athenahealth?', 'plan the interfaces for our new urgent care lab', 'what do I need on site to connect these analyzers?'). Returns one plan: per analyzer the connection status (Driver built, Connection guide, or Catenix builds the driver, usually within a couple of days), the physical link (serial, network, USB or vendor software), protocol and what is needed on site; the on-site gateway and record-system route; patient matching; and a step-by-step go-live checklist. Renders an interactive Lab Map in ChatGPT and Claude. Does not interpret results.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"analyzers"
],
"properties": {
"ehr": {
"type": "string",
"maxLength": 120,
"description": "EHR, LIS or practice system, if known."
},
"country": {
"type": "string",
"maxLength": 60,
"description": "Country, e.g. 'UK' or 'US'."
},
"setting": {
"type": "string",
"maxLength": 120,
"description": "Type of service, e.g. 'urgent care', 'private lab', 'GP practice'."
},
"analyzers": {
"type": "array",
"items": {
"type": "string",
"maxLength": 120,
"minLength": 1
},
"maxItems": 20,
"minItems": 1,
"description": "Analyzer makes and models as the user wrote them."
}
}
},
"annotations": {
"title": "Plan a lab setup",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Use when someone has quality control (QC) results for a lab or point-of-care test and wants to know whether they break Westgard rules or how they look on a Levey-Jennings chart (e.g. 'do these control values fail any Westgard rules?', 'check my QC: mean 5.0, SD 0.1, values ...', 'is this a 2-2s or 4-1s violation?'). Takes control values in run order plus the target mean and SD (or computes them from the values if the user asks) and evaluates 1-2s (warning), 1-3s, 2-2s, R-4s, 4-1s and 10x. Returns z-scores, the rule hits for each point and a plain summary, and draws a Levey-Jennings chart in ChatGPT and Claude. Up to 500 values. QC statistics only: not a clinical interpretation of any patient result.
| Parameter | Type | Description |
|---|---|---|
| sd | number | Target SD for this control lot and level. |
| mean | number | Target mean for this control lot and level. |
| level | string | Control level, e.g. 'level 1'. |
| units | string | Units of the values. |
| values * | array | Control values in run order, oldest first. |
| analyte | string | Test or analyte name, e.g. 'glucose'. |
| compute_from_values | boolean | True only if the user asks to compute the mean and SD from the values. |
{
"name": "check_qc_westgard",
"title": "Check lab QC values against Westgard rules",
"description": "Use when someone has quality control (QC) results for a lab or point-of-care test and wants to know whether they break Westgard rules or how they look on a Levey-Jennings chart (e.g. 'do these control values fail any Westgard rules?', 'check my QC: mean 5.0, SD 0.1, values ...', 'is this a 2-2s or 4-1s violation?'). Takes control values in run order plus the target mean and SD (or computes them from the values if the user asks) and evaluates 1-2s (warning), 1-3s, 2-2s, R-4s, 4-1s and 10x. Returns z-scores, the rule hits for each point and a plain summary, and draws a Levey-Jennings chart in ChatGPT and Claude. Up to 500 values. QC statistics only: not a clinical interpretation of any patient result.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"values"
],
"properties": {
"sd": {
"type": "number",
"description": "Target SD for this control lot and level.",
"exclusiveMinimum": 0
},
"mean": {
"type": "number",
"description": "Target mean for this control lot and level."
},
"level": {
"type": "string",
"maxLength": 40,
"description": "Control level, e.g. 'level 1'."
},
"units": {
"type": "string",
"maxLength": 30,
"description": "Units of the values."
},
"values": {
"type": "array",
"items": {
"type": "number"
},
"maxItems": 500,
"minItems": 1,
"description": "Control values in run order, oldest first."
},
"analyte": {
"type": "string",
"maxLength": 80,
"description": "Test or analyte name, e.g. 'glucose'."
},
"compute_from_values": {
"type": "boolean",
"description": "True only if the user asks to compute the mean and SD from the values."
}
}
},
"annotations": {
"title": "Westgard QC check",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Use when someone wants to know how much staff time manual entry of analyzer results costs them, or would be saved by connecting analyzers to the EHR or LIS (e.g. 'we run 80 tests a day and typing each result takes 2 minutes, how much time is that?', 'is it worth interfacing our analyzers?'). Uses only the user's own numbers (tests per day, minutes of manual entry per result, sites, optionally results per test, working days and their own error rate) and returns hours per day, month and year and entries not retyped. Adds no benchmarks, prices or error statistics; without an error rate from the user it makes no error estimate.
| Parameter | Type | Description |
|---|---|---|
| sites | integer | Number of sites, default 1. |
| tests_per_day * | number | Tests per day (per site unless tests_per_day_is_total). |
| results_per_test | number | Results produced per test (panels give several). Default 1. |
| error_rate_percent | number | The user's own transcription error rate in percent. Omit unless the user gives it. |
| minutes_per_result * | number | Minutes of manual entry per result. |
| tests_per_day_is_total | boolean | True if tests_per_day is the total across all sites. |
| working_days_per_month | number | Working days a month. Default 21. |
{
"name": "estimate_time_saved",
"title": "Estimate time spent retyping lab results",
"description": "Use when someone wants to know how much staff time manual entry of analyzer results costs them, or would be saved by connecting analyzers to the EHR or LIS (e.g. 'we run 80 tests a day and typing each result takes 2 minutes, how much time is that?', 'is it worth interfacing our analyzers?'). Uses only the user's own numbers (tests per day, minutes of manual entry per result, sites, optionally results per test, working days and their own error rate) and returns hours per day, month and year and entries not retyped. Adds no benchmarks, prices or error statistics; without an error rate from the user it makes no error estimate.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"tests_per_day",
"minutes_per_result"
],
"properties": {
"sites": {
"type": "integer",
"maximum": 10000,
"minimum": 1,
"description": "Number of sites, default 1."
},
"tests_per_day": {
"type": "number",
"maximum": 1000000,
"description": "Tests per day (per site unless tests_per_day_is_total).",
"exclusiveMinimum": 0
},
"results_per_test": {
"type": "number",
"maximum": 100,
"description": "Results produced per test (panels give several). Default 1.",
"exclusiveMinimum": 0
},
"error_rate_percent": {
"type": "number",
"maximum": 100,
"minimum": 0,
"description": "The user's own transcription error rate in percent. Omit unless the user gives it."
},
"minutes_per_result": {
"type": "number",
"maximum": 120,
"description": "Minutes of manual entry per result.",
"exclusiveMinimum": 0
},
"tests_per_day_is_total": {
"type": "boolean",
"description": "True if tests_per_day is the total across all sites."
},
"working_days_per_month": {
"type": "number",
"maximum": 31,
"description": "Working days a month. Default 21.",
"exclusiveMinimum": 0
}
}
},
"annotations": {
"title": "Estimate time saved",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Use when someone is preparing a lab or point-of-care testing service for an inspection or accreditation and wants to know what inspectors look for (e.g. 'what do I need for a CLIA inspection?', 'CAP checklist for QC and competency', 'ISO 15189:2022 readiness', 'UK POCT governance checklist'). Returns a practical checklist (quality control, competency, EQA or proficiency testing, document control, audit trail, result reporting, equipment) with the evidence usually asked for, and which Catenix module keeps those records. General guidance, not legal or regulatory advice.
| Parameter | Type | Description |
|---|---|---|
| framework * | string | clia (US CLIA), cap (CAP accreditation), iso_15189 (ISO 15189:2022), uk_poct (UK POCT governance, MHRA guidance). |
{
"name": "inspection_checklist",
"title": "Lab inspection readiness checklist (CLIA, CAP, ISO 15189, UK POCT)",
"description": "Use when someone is preparing a lab or point-of-care testing service for an inspection or accreditation and wants to know what inspectors look for (e.g. 'what do I need for a CLIA inspection?', 'CAP checklist for QC and competency', 'ISO 15189:2022 readiness', 'UK POCT governance checklist'). Returns a practical checklist (quality control, competency, EQA or proficiency testing, document control, audit trail, result reporting, equipment) with the evidence usually asked for, and which Catenix module keeps those records. General guidance, not legal or regulatory advice.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"framework"
],
"properties": {
"framework": {
"enum": [
"clia",
"cap",
"iso_15189",
"uk_poct"
],
"type": "string",
"description": "clia (US CLIA), cap (CAP accreditation), iso_15189 (ISO 15189:2022), uk_poct (UK POCT governance, MHRA guidance)."
}
}
},
"annotations": {
"title": "Inspection checklist",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Use when someone is choosing or buying a LIS, LIMS, POCT middleware or an analyzer-to-EHR interface and wants an RFP or a list of questions to ask vendors (e.g. 'what should I ask LIS vendors?', 'RFP questions for lab middleware', 'checklist for buying an HL7 interface'). Returns a copyable, vendor-neutral checklist grouped by connectivity, QC and compliance, security and privacy, data and audit trail, implementation and support, pricing, and contract and exit.
| Parameter | Type | Description |
|---|---|---|
| buying | string | What they are buying. Default any. |
| groups | array | Only these groups. Omit for all. |
{
"name": "vendor_questions",
"title": "Questions to ask when buying a LIS, middleware or lab interface",
"description": "Use when someone is choosing or buying a LIS, LIMS, POCT middleware or an analyzer-to-EHR interface and wants an RFP or a list of questions to ask vendors (e.g. 'what should I ask LIS vendors?', 'RFP questions for lab middleware', 'checklist for buying an HL7 interface'). Returns a copyable, vendor-neutral checklist grouped by connectivity, QC and compliance, security and privacy, data and audit trail, implementation and support, pricing, and contract and exit.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"properties": {
"buying": {
"enum": [
"lis",
"middleware",
"interface",
"any"
],
"type": "string",
"description": "What they are buying. Default any."
},
"groups": {
"type": "array",
"items": {
"enum": [
"connectivity",
"qc",
"security",
"data",
"implementation",
"pricing",
"exit"
],
"type": "string"
},
"maxItems": 7,
"description": "Only these groups. Omit for all."
}
}
},
"annotations": {
"title": "Vendor questions",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Sends the user's demo request to the Catenix team by email; the team replies to the address the user gives. This is the only tool that shares the user's personal details. Before calling it you MUST show the user every field you will send (name, email, organisation, country, analyzers, record system, message) and get their explicit confirmation in this conversation; then set user_confirmed to true. Never call it on your own initiative. The Catenix widget may call it only after it has shown the user every field and the user pressed Confirm and send. Do not guess missing fields: ask for them.
| Parameter | Type | Description |
|---|---|---|
| ehr * | string | EHR, LIS or practice system ('none' if none). |
| name * | string | The user's name. |
| email * | string | The user's work email. |
| country * | string | Country of the site. |
| message | string | Anything else the user wants to say. |
| analysers * | string | Analyzers they run, comma separated. |
| organisation * | string | Lab, clinic or company name. |
| user_confirmed * | boolean | True only after the user explicitly confirmed the exact details shown to them. |
{
"name": "request_demo",
"title": "Request a Catenix demo",
"description": "Sends the user's demo request to the Catenix team by email; the team replies to the address the user gives. This is the only tool that shares the user's personal details. Before calling it you MUST show the user every field you will send (name, email, organisation, country, analyzers, record system, message) and get their explicit confirmation in this conversation; then set user_confirmed to true. Never call it on your own initiative. The Catenix widget may call it only after it has shown the user every field and the user pressed Confirm and send. Do not guess missing fields: ask for them.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"name",
"email",
"organisation",
"country",
"analysers",
"ehr",
"user_confirmed"
],
"properties": {
"ehr": {
"type": "string",
"maxLength": 120,
"minLength": 1,
"description": "EHR, LIS or practice system ('none' if none)."
},
"name": {
"type": "string",
"maxLength": 100,
"minLength": 1,
"description": "The user's name."
},
"email": {
"type": "string",
"maxLength": 254,
"minLength": 3,
"description": "The user's work email."
},
"country": {
"type": "string",
"maxLength": 60,
"minLength": 2,
"description": "Country of the site."
},
"message": {
"type": "string",
"maxLength": 2000,
"description": "Anything else the user wants to say."
},
"analysers": {
"type": "string",
"maxLength": 500,
"minLength": 1,
"description": "Analyzers they run, comma separated."
},
"organisation": {
"type": "string",
"maxLength": 160,
"minLength": 1,
"description": "Lab, clinic or company name."
},
"user_confirmed": {
"type": "boolean",
"description": "True only after the user explicitly confirmed the exact details shown to them."
}
}
},
"annotations": {
"title": "Request a demo",
"readOnlyHint": false,
"openWorldHint": true,
"idempotentHint": false,
"destructiveHint": false
}
}Catenix answers questions about connecting lab and point-of-care analysers to EHRs, LIS and practice systems, and about software for small labs and clinics (QC, Westgard rules, lockout, operator competency, EQA, audit trail). Use check_connectivity for 'will my analyser connect to my EHR', plan_lab_setup for several analysers plus a record system (it draws a Lab Map), recommend_lab_setup for 'what software or LIS does my lab or clinic need', search_analyzers to list supported instruments, get_ehr_integration for a record system, compare_options for LIS vs middleware or vendor comparisons, and get_platform_capability for QC and compliance features. Use decode_lab_message when someone pastes an HL7 v2, ASTM or POCT1-A2 message, check_qc_westgard for QC values against a mean and SD, estimate_time_saved for the user's own manual-entry numbers, inspection_checklist for CLIA, CAP, ISO 15189:2022 or UK POCT inspection readiness, and vendor_questions for an RFP or buying checklist. Tell users to paste only test or de-identified messages. QC and decoding outputs are statistics and structure, never clinical interpretation. Report statuses exactly as returned (live, driver built, connectable via standard protocol, or custom driver). Never invent prices. Catenix does not interpret results or give clinical advice: if the user asks a clinical question, say so and suggest they ask their clinician or laboratory. Only call request_demo after the user has explicitly confirmed the exact details to send.
Names, descriptions and schemas were written by the server and are shown as data.