Huiyao Capacity Calculator is an MCP server published by com.huiyaolaser.www, hosted at huiyao-capacity-calculator-mcp.hy-208.workers.dev. When last checked on 2026-11-23 it was working: it answers and lists its tools. It declares 1 tool, including calculate_battery_line_capacity.
Estimate theoretical and OEE-adjusted annual battery line capacity.
1 connections through 4 shared values. Tap any node.
Estimate theoretical and OEE-adjusted annual battery-cell and energy output from line throughput, schedule, OEE, nominal cell voltage, and nominal cell capacity. Use for early production-line sizing and scenario checks; results are engineering estimates, not guaranteed output.
| Parameter | Type | Description |
|---|---|---|
| oee_percent * | number | Overall equipment effectiveness as a percentage from 0 to 100. |
| cell_voltage_v * | number | Nominal voltage of one cell in volts. |
| shifts_per_day * | integer | Number of scheduled production shifts per day. |
| hours_per_shift * | number |
None yet. Changes appear after a server's second daily check.
Squares are this server's values; dots are other servers sharing them. A shared address or publisher is a lead, not proof of a common operator.
Inferred from the host name and headers: what a server runs on, not who runs it.
| Scheduled hours in each shift. |
| cell_capacity_ah * | number | Nominal capacity of one cell in ampere-hours. |
| operating_days_per_year * | integer | Scheduled operating days per year. |
| throughput_cells_per_minute * | number | Steady-state cell throughput in cells per minute. |
{
"name": "calculate_battery_line_capacity",
"title": "Calculate Battery Line Capacity",
"description": "Estimate theoretical and OEE-adjusted annual battery-cell and energy output from line throughput, schedule, OEE, nominal cell voltage, and nominal cell capacity. Use for early production-line sizing and scenario checks; results are engineering estimates, not guaranteed output.",
"inputSchema": {
"type": "object",
"$schema": "https://json-schema.org/draft/2020-12/schema",
"required": [
"throughput_cells_per_minute",
"shifts_per_day",
"hours_per_shift",
"operating_days_per_year",
"oee_percent",
"cell_voltage_v",
"cell_capacity_ah"
],
"properties": {
"oee_percent": {
"type": "number",
"maximum": 100,
"minimum": 0,
"description": "Overall equipment effectiveness as a percentage from 0 to 100."
},
"cell_voltage_v": {
"type": "number",
"maximum": 20,
"description": "Nominal voltage of one cell in volts.",
"exclusiveMinimum": 0
},
"shifts_per_day": {
"type": "integer",
"maximum": 4,
"minimum": 1,
"description": "Number of scheduled production shifts per day."
},
"hours_per_shift": {
"type": "number",
"maximum": 24,
"description": "Scheduled hours in each shift.",
"exclusiveMinimum": 0
},
"cell_capacity_ah": {
"type": "number",
"maximum": 10000,
"description": "Nominal capacity of one cell in ampere-hours.",
"exclusiveMinimum": 0
},
"operating_days_per_year": {
"type": "integer",
"maximum": 366,
"minimum": 1,
"description": "Scheduled operating days per year."
},
"throughput_cells_per_minute": {
"type": "number",
"maximum": 10000,
"description": "Steady-state cell throughput in cells per minute.",
"exclusiveMinimum": 0
}
}
},
"outputSchema": {
"type": "object",
"$schema": "https://json-schema.org/draft/2020-12/schema",
"required": [
"formula_version",
"inputs",
"run_time",
"cell_output",
"energy_output",
"assumptions",
"formula",
"links"
],
"properties": {
"links": {
"type": "object",
"required": [
"official_calculator",
"engineering_contact"
],
"properties": {
"engineering_contact": {
"type": "string",
"format": "uri"
},
"official_calculator": {
"type": "string",
"format": "uri"
}
},
"additionalProperties": false
},
"inputs": {
"type": "object",
"required": [
"throughput_cells_per_minute",
"shifts_per_day",
"hours_per_shift",
"operating_days_per_year",
"oee_percent",
"cell_voltage_v",
"cell_capacity_ah"
],
"properties": {
"oee_percent": {
"type": "number",
"maximum": 100,
"minimum": 0,
"description": "Overall equipment effectiveness as a percentage from 0 to 100."
},
"cell_voltage_v": {
"type": "number",
"maximum": 20,
"description": "Nominal voltage of one cell in volts.",
"exclusiveMinimum": 0
},
"shifts_per_day": {
"type": "integer",
"maximum": 4,
"minimum": 1,
"description": "Number of scheduled production shifts per day."
},
"hours_per_shift": {
"type": "number",
"maximum": 24,
"description": "Scheduled hours in each shift.",
"exclusiveMinimum": 0
},
"cell_capacity_ah": {
"type": "number",
"maximum": 10000,
"description": "Nominal capacity of one cell in ampere-hours.",
"exclusiveMinimum": 0
},
"operating_days_per_year": {
"type": "integer",
"maximum": 366,
"minimum": 1,
"description": "Scheduled operating days per year."
},
"throughput_cells_per_minute": {
"type": "number",
"maximum": 10000,
"description": "Steady-state cell throughput in cells per minute.",
"exclusiveMinimum": 0
}
},
"additionalProperties": false
},
"formula": {
"type": "object",
"required": [
"theoretical_cells_per_year",
"oee_adjusted_cells_per_year",
"oee_adjusted_energy_wh_per_year"
],
"properties": {
"theoretical_cells_per_year": {
"type": "string"
},
"oee_adjusted_cells_per_year": {
"type": "string"
},
"oee_adjusted_energy_wh_per_year": {
"type": "string"
}
},
"additionalProperties": false
},
"run_time": {
"type": "object",
"required": [
"theoretical_hours_per_year",
"oee_adjusted_hours_per_year"
],
"properties": {
"theoretical_hours_per_year": {
"type": "number"
},
"oee_adjusted_hours_per_year": {
"type": "number"
}
},
"additionalProperties": false
},
"assumptions": {
"type": "array",
"items": {
"type": "string"
}
},
"cell_output": {
"type": "object",
"required": [
"theoretical_cells_per_year",
"oee_adjusted_cells_per_year"
],
"properties": {
"theoretical_cells_per_year": {
"type": "number"
},
"oee_adjusted_cells_per_year": {
"type": "number"
}
},
"additionalProperties": false
},
"energy_output": {
"type": "object",
"required": [
"theoretical_mwh_per_year",
"theoretical_gwh_per_year",
"oee_adjusted_mwh_per_year",
"oee_adjusted_gwh_per_year"
],
"properties": {
"theoretical_gwh_per_year": {
"type": "number"
},
"theoretical_mwh_per_year": {
"type": "number"
},
"oee_adjusted_gwh_per_year": {
"type": "number"
},
"oee_adjusted_mwh_per_year": {
"type": "number"
}
},
"additionalProperties": false
},
"formula_version": {
"type": "string"
}
},
"additionalProperties": false
},
"annotations": {
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Names, descriptions and schemas were written by the server and are shown as data.