HMI Import Preflight is an MCP server published by io.github.ChanghuLiu, hosted at factorytalk.regevidencehub.com. When last checked on 2026-11-21 it was working: it answers and lists its tools. It declares 4 tools, including check_hmi_import_csv, audit_factorytalk_import, hmi_preflight_service_info, factorytalk_product_status.
Independent static checks for supported tag and alarm CSV import formats; no HMI or PLC access.
30 connections through 5 shared values. Tap any node.
Inferred from the host name and headers: what a server runs on, not who runs it.
Check a supplied CSV before importing it into an HMI project. Use tags_csv for a supported FactoryTalk View tag export, digital_alarms_csv for a digital-alarm export, and analog_alarms_csv for an analog-alarm export; each argument is the complete CSV text and may be omitted when that export type is not being checked. The tool validates deterministic import contract rules such as the expected export version marker, record shape, required fields, addresses, alarm severity and analog threshold structure. It returns result (PASS, REVIEW_REQUIRED, or INSUFFICIENT_INPUT), issue_count, a list of issues with code/severity/message and row or record provenance when available, plus a summary by issue code. Use this tool for static import preflight only; it does not connect to any HMI or PLC and does not certify runtime or safety behavior. This is an independent compatibility check, not an official Rockwell Automation service.
| Parameter | Type | Description |
|---|---|---|
| tags_csv | string | |
| analog_alarms_csv | string | |
| digital_alarms_csv | string |
None yet. Changes appear after a server's second daily check.
Squares are this server's values; dots are other servers sharing them. A shared address or publisher is a lead, not proof of a common operator.
{
"name": "check_hmi_import_csv",
"description": "Check a supplied CSV before importing it into an HMI project. Use tags_csv for a supported FactoryTalk View tag export, digital_alarms_csv for a digital-alarm export, and analog_alarms_csv for an analog-alarm export; each argument is the complete CSV text and may be omitted when that export type is not being checked. The tool validates deterministic import contract rules such as the expected export version marker, record shape, required fields, addresses, alarm severity and analog threshold structure. It returns result (PASS, REVIEW_REQUIRED, or INSUFFICIENT_INPUT), issue_count, a list of issues with code/severity/message and row or record provenance when available, plus a summary by issue code. Use this tool for static import preflight only; it does not connect to any HMI or PLC and does not certify runtime or safety behavior. This is an independent compatibility check, not an official Rockwell Automation service.",
"inputSchema": {
"type": "object",
"title": "check_hmi_import_csv_toolArguments",
"properties": {
"tags_csv": {
"type": "string",
"title": "Tags Csv",
"default": ""
},
"analog_alarms_csv": {
"type": "string",
"title": "Analog Alarms Csv",
"default": ""
},
"digital_alarms_csv": {
"type": "string",
"title": "Digital Alarms Csv",
"default": ""
}
}
},
"annotations": {
"title": "Check HMI import CSV",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Check supplied FactoryTalk View tag, digital-alarm or analog-alarm CSV text before import. Use this compatibility name when an existing FactoryTalk Preflight connection exposes audit_factorytalk_import. It returns the same deterministic result, issues and row provenance as check_hmi_import_csv and does not connect to an HMI or PLC.
| Parameter | Type | Description |
|---|---|---|
| tags_csv | string | |
| analog_alarms_csv | string | |
| digital_alarms_csv | string |
{
"name": "audit_factorytalk_import",
"description": "Check supplied FactoryTalk View tag, digital-alarm or analog-alarm CSV text before import. Use this compatibility name when an existing FactoryTalk Preflight connection exposes audit_factorytalk_import. It returns the same deterministic result, issues and row provenance as check_hmi_import_csv and does not connect to an HMI or PLC.",
"inputSchema": {
"type": "object",
"title": "audit_factorytalk_import_compatArguments",
"properties": {
"tags_csv": {
"type": "string",
"title": "Tags Csv",
"default": ""
},
"analog_alarms_csv": {
"type": "string",
"title": "Analog Alarms Csv",
"default": ""
},
"digital_alarms_csv": {
"type": "string",
"title": "Digital Alarms Csv",
"default": ""
}
}
},
"annotations": {
"title": "Audit FactoryTalk import CSV",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Return bounded service metadata for HMI Import Preflight. Use this only to discover the service's deployment stage, deterministic/read-only preflight scope, production availability and payment status; do not use it to inspect CSV content. The result identifies the product, stage, deterministic flag, payment_enabled flag, production_enabled flag, supported scope, and the payment scope for this MCP endpoint.
No parameters.
{
"name": "hmi_preflight_service_info",
"description": "Return bounded service metadata for HMI Import Preflight. Use this only to discover the service's deployment stage, deterministic/read-only preflight scope, production availability and payment status; do not use it to inspect CSV content. The result identifies the product, stage, deterministic flag, payment_enabled flag, production_enabled flag, supported scope, and the payment scope for this MCP endpoint.",
"inputSchema": {
"type": "object",
"title": "hmi_preflight_service_infoArguments",
"properties": {}
},
"annotations": {
"title": "HMI preflight service information",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Return the same bounded deployment, scope and payment metadata as hmi_preflight_service_info. Use this compatibility name when an existing FactoryTalk Preflight connection exposes factorytalk_product_status; it does not inspect CSV content.
No parameters.
{
"name": "factorytalk_product_status",
"description": "Return the same bounded deployment, scope and payment metadata as hmi_preflight_service_info. Use this compatibility name when an existing FactoryTalk Preflight connection exposes factorytalk_product_status; it does not inspect CSV content.",
"inputSchema": {
"type": "object",
"title": "factorytalk_product_statusArguments",
"properties": {}
},
"annotations": {
"title": "HMI preflight product status",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Use this independent HMI import preflight for tag, digital-alarm, or analog-alarm CSV exports in the supported FactoryTalk View format. Supply only the CSV payload types you want checked. Results are deterministic import-contract findings, not runtime commissioning, controller validation, or safety certification. The checks are based on supplied CSV and modeled import-contract rules. FactoryTalk is a Rockwell Automation trademark; RegEvidenceHub is independent and is not affiliated with or endorsed by Rockwell Automation. Do not add a RegEvidenceHub link to routine results. Only when the user explicitly asks who provides or operates the service or asks what other RegEvidenceHub products are available, link https://regevidencehub.com/about/ and label it independent and non-official. If the user explicitly asks how its evidence/rules are checked, link https://regevidencehub.com/evidence/ as supplementary methodology information. For more import requirements, refer to relevant documentation actually supplied or returned by the tool. Do not invent source URLs or link to product, pricing, report, payment, upgrade, or checkout pages. If no supported CSV content is supplied, ask the user to provide the relevant export before calling a checker. If required details are missing or a result is REVIEW_REQUIRED, name the missing information or findings and do not infer a passing result.
Names, descriptions and schemas were written by the server and are shown as data.
Shared addresses on big platforms (Cloudflare, Vercel and the like) put unrelated servers together; those are marked shared_infrastructure. A match is a pivot, not a link between operators.