VoltPlan Wiring Diagrams is an MCP server published by io.github.YUZU-Hub, hosted at mcp.voltplan.app. When last checked on 2026-11-23 it was working: it answers and lists its tools. It declares 11 tools, including generate_wiring_diagram, find_components, build_bom, list_component_types, calculate_wire_gauge.
Generate 12V/24V/48V wiring diagrams and size wires, fuses, batteries, solar, and inverters.
Nothing else in the archive shares these values.
Inferred from the host name and headers: what a server runs on, not who runs it.
Generate an electrical wiring diagram for campers, boats, or off-grid setups. Returns the schematic as an image (batteries, chargers, protection components, loads) and a link that opens it in the VoltPlan editor to refine, save and turn into a shopping list. Protection components (shunt, main switch, low-voltage cutoff) are auto-generated when both batteries and loads are provided. Show the user the editor link.
| Parameter | Type | Description |
|---|---|---|
| loads | array | Electrical loads / consumers |
| format | string | png (default): an image the client displays. svg: SVG markup as text, without component icons, for clients that save or post-process files. |
| chargers | array | Chargers with their power sources |
None yet. Changes appear after a server's second daily check.
Squares are this server's values; dots are other servers sharing them. A shared address or publisher is a lead, not proof of a common operator.
| batteries | array | Batteries in the system |
| systemName * | string | Name of the electrical system (e.g. "My Camper Van") |
{
"name": "generate_wiring_diagram",
"title": "Generate Wiring Diagram",
"description": "Generate an electrical wiring diagram for campers, boats, or off-grid setups. Returns the schematic as an image (batteries, chargers, protection components, loads) and a link that opens it in the VoltPlan editor to refine, save and turn into a shopping list. Protection components (shunt, main switch, low-voltage cutoff) are auto-generated when both batteries and loads are provided. Show the user the editor link.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"systemName"
],
"properties": {
"loads": {
"type": "array",
"items": {
"type": "object",
"required": [
"name"
],
"properties": {
"name": {
"type": "string",
"description": "Load name (e.g. \"LED Lights\")"
},
"power": {
"type": "number",
"description": "Power consumption in watts. Give this or current."
},
"current": {
"type": "number",
"description": "Current draw in amps. Calculated from power / voltage when omitted."
},
"voltage": {
"type": "number",
"description": "Operating voltage. Defaults to the first battery's voltage (or 12 V)."
}
},
"additionalProperties": false
},
"description": "Electrical loads / consumers"
},
"format": {
"enum": [
"png",
"svg"
],
"type": "string",
"default": "png",
"description": "png (default): an image the client displays. svg: SVG markup as text, without component icons, for clients that save or post-process files."
},
"chargers": {
"type": "array",
"items": {
"type": "object",
"required": [
"name",
"inputVoltage",
"power"
],
"properties": {
"name": {
"type": "string",
"description": "Charger name (e.g. \"MPPT Solar Charger\")"
},
"power": {
"type": "number",
"description": "Power rating in watts"
},
"sourceType": {
"enum": [
"shore",
"solar",
"wind",
"generator",
"alternator"
],
"type": "string",
"description": "Type of power source feeding this charger"
},
"inputVoltage": {
"type": "number",
"description": "Input voltage. For shore/generator (AC) chargers use the regional mains voltage: 230 V in Europe, UK, Australia, most of Asia and Africa; 120 V in North America and Japan. For solar/wind use the panel or turbine output voltage. For alternator use the vehicle system voltage (typically 14 V)."
},
"outputVoltage": {
"type": "number",
"description": "Output voltage. Defaults to the first battery's voltage (or 12 V)."
}
},
"additionalProperties": false
},
"description": "Chargers with their power sources"
},
"batteries": {
"type": "array",
"items": {
"type": "object",
"required": [
"name",
"voltage"
],
"properties": {
"name": {
"type": "string",
"description": "Battery name (e.g. \"LiFePO4 100Ah\")"
},
"voltage": {
"type": "number",
"description": "Nominal voltage (e.g. 12, or 12.8 for LiFePO4)"
},
"energyWh": {
"type": "number",
"description": "Energy in watt-hours. Calculated from capacityAh × voltage when omitted."
},
"capacityAh": {
"type": "number",
"description": "Capacity in amp-hours. Give this or energyWh."
}
},
"additionalProperties": false
},
"description": "Batteries in the system"
},
"systemName": {
"type": "string",
"description": "Name of the electrical system (e.g. \"My Camper Van\")"
}
},
"additionalProperties": false
},
"annotations": {
"readOnlyHint": true,
"openWorldHint": true,
"idempotentHint": true,
"destructiveHint": false
}
}Find real products in VoltPlan's curated component catalogue that match a spec, e.g. a 200 Ah 12 V LiFePO4 battery or a 2000 W pure-sine inverter. Results come closest rating first. The catalogue is small and curated, so results may deviate from the requested spec; check the listed specs. Use it after the calculators (calculate_battery_bank, calculate_solar_size, calculate_inverter_size) have sized the part. Returns product pages and buy links for each product; show them to the user.
| Parameter | Type | Description |
|---|---|---|
| limit | integer | Maximum number of products to return (1-10, default: 5) |
| query | string | Free-text filter; every word must appear in the product (e.g. "LiFePO4", "Victron"). |
| category * | string | Kind of product: battery, solar_panel, solar_charge_controller (MPPT/PWM), dc_dc_charger (alternator / B2B charger), ac_charger (shore / mains battery charger), inverter (incl. inverter-chargers), power_station (portable power station), battery_monitor (shunt / battery monitor), appliance (loads suc… |
| pureSine | boolean | true: only pure sine wave products (inverter, power_station). |
| capacityAh | number | Batteries only: target capacity in amp-hours. Ranks results. |
| capacityWh | number | Batteries and power stations: target energy in watt-hours. Ranks results; for batteries capacityAh wins when both are given. |
| powerWatts | number | Target power rating in watts: inverter continuous W, charger or controller output W, panel W, power station AC output W, appliance W. Ranks results; not used for batteries. |
| systemVoltage | number | System (battery bank) voltage: 12, 24 or 48. Leaves out products built for another voltage. Ignored for solar_panel, power_station and battery_monitor. |
{
"name": "find_components",
"title": "Find Components",
"description": "Find real products in VoltPlan's curated component catalogue that match a spec, e.g. a 200 Ah 12 V LiFePO4 battery or a 2000 W pure-sine inverter. Results come closest rating first. The catalogue is small and curated, so results may deviate from the requested spec; check the listed specs. Use it after the calculators (calculate_battery_bank, calculate_solar_size, calculate_inverter_size) have sized the part. Returns product pages and buy links for each product; show them to the user.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"category"
],
"properties": {
"limit": {
"type": "integer",
"default": 5,
"maximum": 10,
"minimum": 1,
"description": "Maximum number of products to return (1-10, default: 5)"
},
"query": {
"type": "string",
"maxLength": 100,
"description": "Free-text filter; every word must appear in the product (e.g. \"LiFePO4\", \"Victron\")."
},
"category": {
"enum": [
"battery",
"solar_panel",
"solar_charge_controller",
"dc_dc_charger",
"ac_charger",
"inverter",
"power_station",
"battery_monitor",
"appliance"
],
"type": "string",
"description": "Kind of product: battery, solar_panel, solar_charge_controller (MPPT/PWM), dc_dc_charger (alternator / B2B charger), ac_charger (shore / mains battery charger), inverter (incl. inverter-chargers), power_station (portable power station), battery_monitor (shunt / battery monitor), appliance (loads such as fridges, heaters, fans)"
},
"pureSine": {
"type": "boolean",
"description": "true: only pure sine wave products (inverter, power_station)."
},
"capacityAh": {
"type": "number",
"description": "Batteries only: target capacity in amp-hours. Ranks results.",
"exclusiveMinimum": 0
},
"capacityWh": {
"type": "number",
"description": "Batteries and power stations: target energy in watt-hours. Ranks results; for batteries capacityAh wins when both are given.",
"exclusiveMinimum": 0
},
"powerWatts": {
"type": "number",
"description": "Target power rating in watts: inverter continuous W, charger or controller output W, panel W, power station AC output W, appliance W. Ranks results; not used for batteries.",
"exclusiveMinimum": 0
},
"systemVoltage": {
"enum": [
12,
24,
48
],
"type": "number",
"description": "System (battery bank) voltage: 12, 24 or 48. Leaves out products built for another voltage. Ignored for solar_panel, power_station and battery_monitor."
}
},
"additionalProperties": false
},
"annotations": {
"readOnlyHint": true,
"openWorldHint": true,
"idempotentHint": true,
"destructiveHint": false
}
}Build the shopping list (bill of materials) for the same system generate_wiring_diagram takes: components with matching products from VoltPlan's catalogue, cable per gauge with lengths, fuses, fuse holders, terminals and tools, sized with the same rules as the diagram. Returns buy links for every line and a link that opens the system in the VoltPlan editor; show them to the user.
| Parameter | Type | Description |
|---|---|---|
| loads | array | Electrical loads / consumers |
| chargers | array | Chargers with their power sources |
| batteries | array | Batteries in the system |
| systemName * | string | Name of the electrical system (e.g. "My Camper Van") |
{
"name": "build_bom",
"title": "Build Shopping List",
"description": "Build the shopping list (bill of materials) for the same system generate_wiring_diagram takes: components with matching products from VoltPlan's catalogue, cable per gauge with lengths, fuses, fuse holders, terminals and tools, sized with the same rules as the diagram. Returns buy links for every line and a link that opens the system in the VoltPlan editor; show them to the user.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"systemName"
],
"properties": {
"loads": {
"type": "array",
"items": {
"type": "object",
"required": [
"name"
],
"properties": {
"name": {
"type": "string",
"description": "Load name (e.g. \"LED Lights\")"
},
"power": {
"type": "number",
"description": "Power consumption in watts. Give this or current."
},
"current": {
"type": "number",
"description": "Current draw in amps. Calculated from power / voltage when omitted."
},
"voltage": {
"type": "number",
"description": "Operating voltage. Defaults to the first battery's voltage (or 12 V)."
}
},
"additionalProperties": false
},
"description": "Electrical loads / consumers"
},
"chargers": {
"type": "array",
"items": {
"type": "object",
"required": [
"name",
"inputVoltage",
"power"
],
"properties": {
"name": {
"type": "string",
"description": "Charger name (e.g. \"MPPT Solar Charger\")"
},
"power": {
"type": "number",
"description": "Power rating in watts"
},
"sourceType": {
"enum": [
"shore",
"solar",
"wind",
"generator",
"alternator"
],
"type": "string",
"description": "Type of power source feeding this charger"
},
"inputVoltage": {
"type": "number",
"description": "Input voltage. For shore/generator (AC) chargers use the regional mains voltage: 230 V in Europe, UK, Australia, most of Asia and Africa; 120 V in North America and Japan. For solar/wind use the panel or turbine output voltage. For alternator use the vehicle system voltage (typically 14 V)."
},
"outputVoltage": {
"type": "number",
"description": "Output voltage. Defaults to the first battery's voltage (or 12 V)."
}
},
"additionalProperties": false
},
"description": "Chargers with their power sources"
},
"batteries": {
"type": "array",
"items": {
"type": "object",
"required": [
"name",
"voltage"
],
"properties": {
"name": {
"type": "string",
"description": "Battery name (e.g. \"LiFePO4 100Ah\")"
},
"voltage": {
"type": "number",
"description": "Nominal voltage (e.g. 12, or 12.8 for LiFePO4)"
},
"energyWh": {
"type": "number",
"description": "Energy in watt-hours. Calculated from capacityAh × voltage when omitted."
},
"capacityAh": {
"type": "number",
"description": "Capacity in amp-hours. Give this or energyWh."
}
},
"additionalProperties": false
},
"description": "Batteries in the system"
},
"systemName": {
"type": "string",
"description": "Name of the electrical system (e.g. \"My Camper Van\")"
}
},
"additionalProperties": false
},
"annotations": {
"readOnlyHint": true,
"openWorldHint": true,
"idempotentHint": true,
"destructiveHint": false
}
}List all available component types and example configurations for building wiring diagrams. Use this to understand what parameters are needed before calling generate_wiring_diagram.
No parameters.
{
"name": "list_component_types",
"title": "List Component Types",
"description": "List all available component types and example configurations for building wiring diagrams. Use this to understand what parameters are needed before calling generate_wiring_diagram.",
"inputSchema": {
"type": "object",
"properties": {}
},
"annotations": {
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Calculate the recommended wire gauge / cable cross-section for a DC circuit. Considers both ampacity (current carrying capacity) and voltage drop to recommend the optimal cable size. Also returns total resistance, power loss, and a fuse recommendation. Supports copper conductors from 0.75 mm² (18 AWG) to 240 mm² (300 MCM).
| Parameter | Type | Description |
|---|---|---|
| power | number | Load power in watts. Will be converted to current using the voltage. Provide either current or power. |
| current | number | Load current in amps. Provide either current or power. |
| voltage * | number | System voltage in volts (e.g. 12, 24, 48) |
| isRoundTrip | boolean | Account for both positive and negative conductor (default: true). Set to false for chassis-ground returns. |
| cableLengthM * | number | One-way cable length in meters |
| temperatureCelsius | number | Ambient temperature in °C (default: 20°C). Affects copper resistance. |
| maxVoltageDropPercent | number | Maximum acceptable voltage drop in percent (default: 3%) |
{
"name": "calculate_wire_gauge",
"title": "Cable Cross-Section & Resistance Calculator",
"description": "Calculate the recommended wire gauge / cable cross-section for a DC circuit. Considers both ampacity (current carrying capacity) and voltage drop to recommend the optimal cable size. Also returns total resistance, power loss, and a fuse recommendation. Supports copper conductors from 0.75 mm² (18 AWG) to 240 mm² (300 MCM).",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"voltage",
"cableLengthM"
],
"properties": {
"power": {
"type": "number",
"description": "Load power in watts. Will be converted to current using the voltage. Provide either current or power."
},
"current": {
"type": "number",
"description": "Load current in amps. Provide either current or power."
},
"voltage": {
"type": "number",
"description": "System voltage in volts (e.g. 12, 24, 48)"
},
"isRoundTrip": {
"type": "boolean",
"default": true,
"description": "Account for both positive and negative conductor (default: true). Set to false for chassis-ground returns."
},
"cableLengthM": {
"type": "number",
"description": "One-way cable length in meters"
},
"temperatureCelsius": {
"type": "number",
"default": 20,
"description": "Ambient temperature in °C (default: 20°C). Affects copper resistance."
},
"maxVoltageDropPercent": {
"type": "number",
"default": 3,
"description": "Maximum acceptable voltage drop in percent (default: 3%)"
}
},
"additionalProperties": false
},
"annotations": {
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Calculate total daily energy consumption from a list of electrical loads. Each load specifies its power draw, how many hours per day it runs, and quantity. Returns total daily energy (Wh and Ah), peak power draw, and average power. This is typically the first step in sizing a battery bank and solar system.
| Parameter | Type | Description |
|---|---|---|
| loads * | array | List of electrical loads to include in the budget |
| systemVoltage * | number | System voltage in volts (e.g. 12, 24, 48) |
{
"name": "calculate_power_budget",
"title": "Power Budget / Energy Audit",
"description": "Calculate total daily energy consumption from a list of electrical loads. Each load specifies its power draw, how many hours per day it runs, and quantity. Returns total daily energy (Wh and Ah), peak power draw, and average power. This is typically the first step in sizing a battery bank and solar system.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"systemVoltage",
"loads"
],
"properties": {
"loads": {
"type": "array",
"items": {
"type": "object",
"required": [
"name",
"powerWatts",
"hoursPerDay"
],
"properties": {
"name": {
"type": "string",
"description": "Name of the load (e.g. \"LED Lights\")"
},
"quantity": {
"type": "number",
"default": 1,
"description": "Number of identical units (default: 1)"
},
"powerWatts": {
"type": "number",
"description": "Power consumption of a single unit in watts"
},
"hoursPerDay": {
"type": "number",
"description": "Average hours of use per day"
}
},
"additionalProperties": false
},
"description": "List of electrical loads to include in the budget"
},
"systemVoltage": {
"type": "number",
"description": "System voltage in volts (e.g. 12, 24, 48)"
}
},
"additionalProperties": false
},
"annotations": {
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Calculate the recommended battery bank size based on daily energy consumption. Accounts for days of autonomy (how many days without charging) and depth of discharge. Returns required capacity, number of batteries, and wiring configuration.
| Parameter | Type | Description |
|---|---|---|
| systemVoltage * | number | Target system voltage in volts (e.g. 12, 24, 48) |
| daysOfAutonomy | number | Days the system should run without any charging (default: 2) |
| singleBatteryAh * | number | Capacity of a single battery in amp-hours (e.g. 100, 200) |
| dailyConsumptionWh * | number | Daily energy consumption in watt-hours (from calculate_power_budget) |
| singleBatteryVoltage * | number | Voltage of a single battery (e.g. 12.8 for LiFePO4, 12 for lead-acid) |
| depthOfDischargePercent | number | Usable percentage of battery capacity. LiFePO4: 80-90%, AGM: 50%, Gel: 50% (default: 80) |
{
"name": "calculate_battery_bank",
"title": "Battery Bank Sizing Calculator",
"description": "Calculate the recommended battery bank size based on daily energy consumption. Accounts for days of autonomy (how many days without charging) and depth of discharge. Returns required capacity, number of batteries, and wiring configuration.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"dailyConsumptionWh",
"systemVoltage",
"singleBatteryAh",
"singleBatteryVoltage"
],
"properties": {
"systemVoltage": {
"type": "number",
"description": "Target system voltage in volts (e.g. 12, 24, 48)"
},
"daysOfAutonomy": {
"type": "number",
"default": 2,
"description": "Days the system should run without any charging (default: 2)"
},
"singleBatteryAh": {
"type": "number",
"description": "Capacity of a single battery in amp-hours (e.g. 100, 200)"
},
"dailyConsumptionWh": {
"type": "number",
"description": "Daily energy consumption in watt-hours (from calculate_power_budget)"
},
"singleBatteryVoltage": {
"type": "number",
"description": "Voltage of a single battery (e.g. 12.8 for LiFePO4, 12 for lead-acid)"
},
"depthOfDischargePercent": {
"type": "number",
"default": 80,
"description": "Usable percentage of battery capacity. LiFePO4: 80-90%, AGM: 50%, Gel: 50% (default: 80)"
}
},
"additionalProperties": false
},
"annotations": {
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Calculate the required solar panel wattage to cover daily energy consumption. Accounts for peak sun hours at the location and system efficiency losses (MPPT conversion, wiring, temperature derating). Returns required wattage and common panel configurations.
| Parameter | Type | Description |
|---|---|---|
| peakSunHours * | number | Average daily peak sun hours for the location. Examples: Northern Europe winter 1-2h, summer 4-6h. Southern US 5-6h. Equatorial regions 5-7h. |
| systemEfficiency | number | Overall system efficiency factor (default: 0.85). Accounts for MPPT losses, wiring losses, temperature derating, and panel soiling. |
| dailyConsumptionWh * | number | Daily energy consumption in watt-hours (from calculate_power_budget) |
{
"name": "calculate_solar_size",
"title": "Solar Panel Sizing Calculator",
"description": "Calculate the required solar panel wattage to cover daily energy consumption. Accounts for peak sun hours at the location and system efficiency losses (MPPT conversion, wiring, temperature derating). Returns required wattage and common panel configurations.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"dailyConsumptionWh",
"peakSunHours"
],
"properties": {
"peakSunHours": {
"type": "number",
"description": "Average daily peak sun hours for the location. Examples: Northern Europe winter 1-2h, summer 4-6h. Southern US 5-6h. Equatorial regions 5-7h."
},
"systemEfficiency": {
"type": "number",
"default": 0.85,
"description": "Overall system efficiency factor (default: 0.85). Accounts for MPPT losses, wiring losses, temperature derating, and panel soiling."
},
"dailyConsumptionWh": {
"type": "number",
"description": "Daily energy consumption in watt-hours (from calculate_power_budget)"
}
},
"additionalProperties": false
},
"annotations": {
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Estimate how long it takes to charge a battery bank from a given state of charge to a target level. Accounts for the bulk charging phase (constant current, up to ~80% SoC) and the slower absorption phase (tapering current, 80-100% SoC). Works for any charging source: solar, shore power, alternator.
| Parameter | Type | Description |
|---|---|---|
| batteryVoltage * | number | Battery bank voltage (e.g. 12, 24, 48) |
| chargePowerWatts * | number | Charger output power in watts |
| batteryCapacityAh * | number | Total battery bank capacity in amp-hours |
| chargeCurrentAmps | number | Maximum charge current in amps (if limited by the charger or battery BMS). If omitted, calculated from power and voltage. |
| targetStateOfChargePercent | number | Target state of charge in percent (default: 100) |
| currentStateOfChargePercent * | number | Current state of charge in percent (e.g. 20 for 20%) |
{
"name": "calculate_charging_time",
"title": "Charging Time Calculator",
"description": "Estimate how long it takes to charge a battery bank from a given state of charge to a target level. Accounts for the bulk charging phase (constant current, up to ~80% SoC) and the slower absorption phase (tapering current, 80-100% SoC). Works for any charging source: solar, shore power, alternator.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"batteryCapacityAh",
"batteryVoltage",
"currentStateOfChargePercent",
"chargePowerWatts"
],
"properties": {
"batteryVoltage": {
"type": "number",
"description": "Battery bank voltage (e.g. 12, 24, 48)"
},
"chargePowerWatts": {
"type": "number",
"description": "Charger output power in watts"
},
"batteryCapacityAh": {
"type": "number",
"description": "Total battery bank capacity in amp-hours"
},
"chargeCurrentAmps": {
"type": "number",
"description": "Maximum charge current in amps (if limited by the charger or battery BMS). If omitted, calculated from power and voltage."
},
"targetStateOfChargePercent": {
"type": "number",
"default": 100,
"description": "Target state of charge in percent (default: 100)"
},
"currentStateOfChargePercent": {
"type": "number",
"description": "Current state of charge in percent (e.g. 20 for 20%)"
}
},
"additionalProperties": false
},
"annotations": {
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Calculate the recommended inverter size for running AC loads from a DC battery system. Accounts for continuous power, startup surge power (motors typically surge 2-3x), and includes a 25% headroom for the continuous rating. Returns the recommended inverter wattage and the DC current draw at system voltage.
| Parameter | Type | Description |
|---|---|---|
| loads * | array | List of AC loads that will run through the inverter |
| systemVoltage * | number | DC system voltage (e.g. 12, 24, 48) |
{
"name": "calculate_inverter_size",
"title": "Inverter Sizing Calculator",
"description": "Calculate the recommended inverter size for running AC loads from a DC battery system. Accounts for continuous power, startup surge power (motors typically surge 2-3x), and includes a 25% headroom for the continuous rating. Returns the recommended inverter wattage and the DC current draw at system voltage.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"systemVoltage",
"loads"
],
"properties": {
"loads": {
"type": "array",
"items": {
"type": "object",
"required": [
"name",
"continuousWatts"
],
"properties": {
"name": {
"type": "string",
"description": "Name of the AC load (e.g. \"Microwave\", \"Coffee Machine\")"
},
"quantity": {
"type": "number",
"default": 1,
"description": "Number of identical units (default: 1)"
},
"surgeWatts": {
"type": "number",
"description": "Startup surge power in watts (for motors, compressors). If omitted, assumed equal to continuous watts."
},
"continuousWatts": {
"type": "number",
"description": "Continuous power draw in watts"
}
},
"additionalProperties": false
},
"description": "List of AC loads that will run through the inverter"
},
"systemVoltage": {
"type": "number",
"description": "DC system voltage (e.g. 12, 24, 48)"
}
},
"additionalProperties": false
},
"annotations": {
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Determine how to arrange batteries in series and/or parallel to achieve a target voltage and capacity. Returns the number of batteries needed, the wiring configuration (e.g. 2S3P), and step-by-step wiring instructions.
| Parameter | Type | Description |
|---|---|---|
| targetVoltage * | number | Desired system voltage (e.g. 12, 24, 48) |
| singleBatteryAh * | number | Capacity of one battery in amp-hours |
| targetCapacityAh * | number | Desired total capacity in amp-hours |
| singleBatteryVoltage * | number | Nominal voltage of one battery (e.g. 12.8 for LiFePO4, 12 for lead-acid, 3.2 for LiFePO4 cells) |
{
"name": "calculate_battery_config",
"title": "Battery Configuration Calculator",
"description": "Determine how to arrange batteries in series and/or parallel to achieve a target voltage and capacity. Returns the number of batteries needed, the wiring configuration (e.g. 2S3P), and step-by-step wiring instructions.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"targetVoltage",
"targetCapacityAh",
"singleBatteryVoltage",
"singleBatteryAh"
],
"properties": {
"targetVoltage": {
"type": "number",
"description": "Desired system voltage (e.g. 12, 24, 48)"
},
"singleBatteryAh": {
"type": "number",
"description": "Capacity of one battery in amp-hours"
},
"targetCapacityAh": {
"type": "number",
"description": "Desired total capacity in amp-hours"
},
"singleBatteryVoltage": {
"type": "number",
"description": "Nominal voltage of one battery (e.g. 12.8 for LiFePO4, 12 for lead-acid, 3.2 for LiFePO4 cells)"
}
},
"additionalProperties": false
},
"annotations": {
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Names, descriptions and schemas were written by the server and are shown as data.