EV Load Check is an MCP server published by io.github.pindotcom, hosted at ev-load-check.permitev.com. When last checked on 2026-11-21 it was working: it answers and lists its tools. It declares 4 tools, including check_panel_capacity, recommend_charger_setup, check_voltage_drop, lookup_georgia_rebate.
NEC-based screening for a home EV charger: panel capacity, wire sizing, voltage drop, GA incentives.
Nothing else in the archive shares these values.
Squares are this server's values; dots are other servers sharing them. A shared address or publisher is a lead, not proof of a common operator.
Inferred from the host name and headers: what a server runs on, not who runs it.
Check whether a home's electrical panel has capacity for an EV charger. Use when a user asks if their panel or breaker box can handle an EV charger, or whether they need a panel upgrade or load management. Returns a verdict (fits / tight / does-not-fit), amps, and a plain-language explanation.
| Parameter | Type | Description |
|---|---|---|
| appliances | array | Major appliances with nameplate VA. Optional; improves accuracy. |
| charger_amps * | integer | Charger charging current in amps, e.g. 32, 40, 48, 80 |
| square_footage | integer | Home size in square feet. Omit if unknown (assumes 2000). |
| main_breaker_amps * |
None yet. Changes appear after a server's second daily check.
| integer |
| Main breaker rating of the panel in amps, e.g. 100, 150, 200 |
{
"name": "check_panel_capacity",
"title": "Check Panel Capacity",
"description": "Check whether a home's electrical panel has capacity for an EV charger. Use when a user asks if their panel or breaker box can handle an EV charger, or whether they need a panel upgrade or load management. Returns a verdict (fits / tight / does-not-fit), amps, and a plain-language explanation.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"main_breaker_amps",
"charger_amps"
],
"properties": {
"appliances": {
"type": "array",
"items": {
"type": "object",
"required": [
"name",
"va"
],
"properties": {
"va": {
"type": "number",
"description": "Nameplate VA (volts x amps) from the label"
},
"name": {
"type": "string",
"description": "Appliance name, e.g. 'electric range'"
},
"count": {
"type": "number"
}
},
"additionalProperties": false
},
"maxItems": 15,
"description": "Major appliances with nameplate VA. Optional; improves accuracy."
},
"charger_amps": {
"type": "integer",
"maximum": 80,
"minimum": 8,
"description": "Charger charging current in amps, e.g. 32, 40, 48, 80"
},
"square_footage": {
"type": "integer",
"maximum": 20000,
"minimum": 200,
"description": "Home size in square feet. Omit if unknown (assumes 2000)."
},
"main_breaker_amps": {
"type": "integer",
"maximum": 400,
"minimum": 30,
"description": "Main breaker rating of the panel in amps, e.g. 100, 150, 200"
}
},
"additionalProperties": false
},
"annotations": {
"title": "Check Panel Capacity",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Recommend breaker size, wire gauge, conduit, and ground wire for a home EV charger circuit. Use when a user asks what wire size, breaker, or circuit their charger needs. Returns wire gauge, breaker amps, EGC size, and a plain-language explanation with NEC citations.
| Parameter | Type | Description |
|---|---|---|
| charger_amps * | integer | Charger charging current in amps, e.g. 32, 40, 48 |
| run_length_ft | integer | Cable run length in feet. Omit if unknown. |
| wire_material | string | Copper (Cu) or aluminum (Al) wire. Default copper. |
| ambient_temp_c | number | Ambient temperature in Celsius. Default 30 (standard). |
{
"name": "recommend_charger_setup",
"title": "Recommend Charger Setup",
"description": "Recommend breaker size, wire gauge, conduit, and ground wire for a home EV charger circuit. Use when a user asks what wire size, breaker, or circuit their charger needs. Returns wire gauge, breaker amps, EGC size, and a plain-language explanation with NEC citations.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"charger_amps"
],
"properties": {
"charger_amps": {
"type": "integer",
"maximum": 80,
"minimum": 8,
"description": "Charger charging current in amps, e.g. 32, 40, 48"
},
"run_length_ft": {
"type": "integer",
"maximum": 500,
"minimum": 10,
"description": "Cable run length in feet. Omit if unknown."
},
"wire_material": {
"enum": [
"Cu",
"Al"
],
"type": "string",
"description": "Copper (Cu) or aluminum (Al) wire. Default copper."
},
"ambient_temp_c": {
"type": "number",
"maximum": 60,
"minimum": -10,
"description": "Ambient temperature in Celsius. Default 30 (standard)."
}
},
"additionalProperties": false
},
"annotations": {
"title": "Recommend Charger Setup",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Check whether a cable run length causes excessive voltage drop for an EV charger circuit. Use when a user asks about long garage/driveway runs, voltage drop, upsizing wire for distance. Returns pass/fail at 3%.
| Parameter | Type | Description |
|---|---|---|
| wire_size * | string | Wire gauge in AWG, e.g. '8' for 8 AWG |
| charger_amps * | integer | Charging current in amps |
| run_length_ft * | integer | One-way cable run length in feet |
| wire_material | string | Default copper. |
{
"name": "check_voltage_drop",
"title": "Check Voltage Drop",
"description": "Check whether a cable run length causes excessive voltage drop for an EV charger circuit. Use when a user asks about long garage/driveway runs, voltage drop, upsizing wire for distance. Returns pass/fail at 3%.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"charger_amps",
"wire_size",
"run_length_ft"
],
"properties": {
"wire_size": {
"enum": [
"14",
"12",
"10",
"8",
"6",
"4",
"3",
"2",
"1",
"1/0",
"2/0",
"3/0",
"4/0"
],
"type": "string",
"description": "Wire gauge in AWG, e.g. '8' for 8 AWG"
},
"charger_amps": {
"type": "integer",
"maximum": 80,
"minimum": 8,
"description": "Charging current in amps"
},
"run_length_ft": {
"type": "integer",
"maximum": 500,
"minimum": 10,
"description": "One-way cable run length in feet"
},
"wire_material": {
"enum": [
"Cu",
"Al"
],
"type": "string",
"description": "Default copper."
}
},
"additionalProperties": false
},
"annotations": {
"title": "Check Voltage Drop",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Look up Georgia EV charger rebates and incentives: the Georgia Power EV rebate program and the Georgia state tax credit. Use when a user asks about EV charger rebates, incentives, or tax credits in Georgia.
| Parameter | Type | Description |
|---|---|---|
| charger_type | string | Level 2 charger or DC fast charger. Default level2. |
{
"name": "lookup_georgia_rebate",
"title": "Lookup Georgia Rebate",
"description": "Look up Georgia EV charger rebates and incentives: the Georgia Power EV rebate program and the Georgia state tax credit. Use when a user asks about EV charger rebates, incentives, or tax credits in Georgia.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"properties": {
"charger_type": {
"enum": [
"level2",
"dcfc",
"unknown"
],
"type": "string",
"description": "Level 2 charger or DC fast charger. Default level2."
}
},
"additionalProperties": false
},
"annotations": {
"title": "Lookup Georgia Rebate",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Names, descriptions and schemas were written by the server and are shown as data.