Recall365 — Global Product Recalls is an MCP server published by io.recall365, hosted at app.recall365.io. When last checked on 2026-11-23 it was working: it answers and lists its tools. It declares 6 tools, including search_recalls, get_recall, brand_recall_history, precheck_product, fda_import_alerts.
Search official product recalls from US, EU, UK, CA, AU, JP, KR, CN regulators and FDA red lists.
Nothing else in the archive shares these values.
Squares are this server's values; dots are other servers sharing them. A shared address or publisher is a lead, not proof of a common operator.
Inferred from the host name and headers: what a server runs on, not who runs it.
Search official product recalls by keyword (product, brand, hazard; Chinese/English/Korean brand names are cross-matched). Returns at most 20 newest/most relevant notices with links.
| Parameter | Type | Description |
|---|---|---|
| lang | string | Output language: zh = 中文, en = English. Default en. |
| limit | integer | |
| query | string | Keyword, e.g. 'power bank', '婴儿床', 'BMW'. Optional if filters are given. |
| since | string | Earliest publish date, YYYY-MM-DD. |
| offset | integer | |
| country | string | Recall market ISO code, e.g. US, EU, UK, CA, AU, NZ, JP, KR, CN. |
| category | string | one of ["auto","consumer","food","health"] |
| made_in_china | boolean | Only products whose origin is China. |
| border_rejection | boolean | Only EU RASFF border rejections (food refused at the EU border, not recalled). |
{
"name": "search_recalls",
"title": "Search recalls",
"description": "Search official product recalls by keyword (product, brand, hazard; Chinese/English/Korean brand names are cross-matched). Returns at most 20 newest/most relevant notices with links.",
"inputSchema": {
"type": "object",
"properties": {
"lang": {
"enum": [
"zh",
"en"
],
"type": "string",
"description": "Output language: zh = 中文, en = English. Default en."
},
"limit": {
"type": "integer",
"default": 10,
"maximum": 20,
"minimum": 1
},
"query": {
"type": "string",
"description": "Keyword, e.g. 'power bank', '婴儿床', 'BMW'. Optional if filters are given."
},
"since": {
"type": "string",
"description": "Earliest publish date, YYYY-MM-DD."
},
"offset": {
"type": "integer",
"default": 0,
"maximum": 100,
"minimum": 0
},
"country": {
"type": "string",
"description": "Recall market ISO code, e.g. US, EU, UK, CA, AU, NZ, JP, KR, CN."
},
"category": {
"enum": [
"auto",
"consumer",
"food",
"health"
],
"type": "string"
},
"made_in_china": {
"type": "boolean",
"description": "Only products whose origin is China."
},
"border_rejection": {
"type": "boolean",
"description": "Only EU RASFF border rejections (food refused at the EU border, not recalled)."
}
}
},
"annotations": {
"title": "Search recalls",
"readOnlyHint": true,
"openWorldHint": false
}
}Full detail of one recall by its Recall365 id: product, brand, hazard, failed standards, remedy, official notice link.
| Parameter | Type | Description |
|---|---|---|
| id * | integer | Recall365 id from search results. |
| lang | string | Output language: zh = 中文, en = English. Default en. |
{
"name": "get_recall",
"title": "Get one recall",
"description": "Full detail of one recall by its Recall365 id: product, brand, hazard, failed standards, remedy, official notice link.",
"inputSchema": {
"type": "object",
"required": [
"id"
],
"properties": {
"id": {
"type": "integer",
"description": "Recall365 id from search results."
},
"lang": {
"enum": [
"zh",
"en"
],
"type": "string",
"description": "Output language: zh = 中文, en = English. Default en."
}
}
},
"annotations": {
"title": "Get one recall",
"readOnlyHint": true,
"openWorldHint": false
}
}Recall history of a brand across all markets: totals by year, country and category, plus the 10 latest notices.
| Parameter | Type | Description |
|---|---|---|
| lang | string | Output language: zh = 中文, en = English. Default en. |
| brand * | string | Brand name, e.g. 'Anker', '小米'. |
{
"name": "brand_recall_history",
"title": "Brand recall history",
"description": "Recall history of a brand across all markets: totals by year, country and category, plus the 10 latest notices.",
"inputSchema": {
"type": "object",
"required": [
"brand"
],
"properties": {
"lang": {
"enum": [
"zh",
"en"
],
"type": "string",
"description": "Output language: zh = 中文, en = English. Default en."
},
"brand": {
"type": "string",
"description": "Brand name, e.g. 'Anker', '小米'."
}
}
},
"annotations": {
"title": "Brand recall history",
"readOnlyHint": true,
"openWorldHint": false
}
}Risk profile for a product type before selling it abroad: recalls in the last 3 years, share made in China, top hazards, top markets, yearly trend, typical cases and self-check advice.
| Parameter | Type | Description |
|---|---|---|
| lang | string | Output language: zh = 中文, en = English. Default en. |
| country | string | Recall market ISO code, e.g. US, EU, UK, CA, AU, NZ, JP, KR, CN. |
| product * | string | Product type, e.g. 'baby stroller', '充电宝'. |
{
"name": "precheck_product",
"title": "Pre-export risk check",
"description": "Risk profile for a product type before selling it abroad: recalls in the last 3 years, share made in China, top hazards, top markets, yearly trend, typical cases and self-check advice.",
"inputSchema": {
"type": "object",
"required": [
"product"
],
"properties": {
"lang": {
"enum": [
"zh",
"en"
],
"type": "string",
"description": "Output language: zh = 中文, en = English. Default en."
},
"country": {
"type": "string",
"description": "Recall market ISO code, e.g. US, EU, UK, CA, AU, NZ, JP, KR, CN."
},
"product": {
"type": "string",
"description": "Product type, e.g. 'baby stroller', '充电宝'."
}
}
},
"annotations": {
"title": "Pre-export risk check",
"readOnlyHint": true,
"openWorldHint": false
}
}Search the FDA Import Alert red lists: firms whose products can be detained at the US border without physical examination. Search by firm name, city or product (e.g. 'laser', 'eye shadow', 'Shenzhen'). Defaults to firms in China.
| Parameter | Type | Description |
|---|---|---|
| lang | string | Output language: zh = 中文, en = English. Default en. |
| alert | string | Import alert number, e.g. 95-05. |
| limit | integer | |
| query | string | Firm name, city or product keyword. Optional. |
| since | string | Only firms listed on/after YYYY-MM-DD. |
| country | string | ISO code (CN default, HK, IN, VN…) or ALL. |
{
"name": "fda_import_alerts",
"title": "FDA import alert red list",
"description": "Search the FDA Import Alert red lists: firms whose products can be detained at the US border without physical examination. Search by firm name, city or product (e.g. 'laser', 'eye shadow', 'Shenzhen'). Defaults to firms in China.",
"inputSchema": {
"type": "object",
"properties": {
"lang": {
"enum": [
"zh",
"en"
],
"type": "string",
"description": "Output language: zh = 中文, en = English. Default en."
},
"alert": {
"type": "string",
"description": "Import alert number, e.g. 95-05."
},
"limit": {
"type": "integer",
"default": 10,
"maximum": 20,
"minimum": 1
},
"query": {
"type": "string",
"description": "Firm name, city or product keyword. Optional."
},
"since": {
"type": "string",
"description": "Only firms listed on/after YYYY-MM-DD."
},
"country": {
"type": "string",
"description": "ISO code (CN default, HK, IN, VN…) or ALL."
}
}
},
"annotations": {
"title": "FDA import alert red list",
"readOnlyHint": true,
"openWorldHint": false
}
}Which official sources are covered, record counts, and the latest publish date per source (how fresh the data is).
No parameters.
{
"name": "data_coverage",
"title": "Data coverage",
"description": "Which official sources are covered, record counts, and the latest publish date per source (how fresh the data is).",
"inputSchema": {
"type": "object",
"properties": {}
},
"annotations": {
"title": "Data coverage",
"readOnlyHint": true,
"openWorldHint": false
}
}Recall365 indexes official product recalls (auto, consumer products, food, health products) from the US, EU, UK, Canada, Australia, New Zealand, Japan, Korea, China and more, translated to Chinese and English, with a made-in-China flag, normalized hazards and brands. Use search_recalls for lookups, get_recall for one notice, brand_recall_history for a brand, precheck_product for a pre-export risk profile of a product type, fda_import_alerts to check whether a firm is on an FDA import-alert red list (detention at the US border), data_coverage to see how fresh each source is. Always link the returned url so users can verify. Answer in the user's language (lang=zh for Chinese, en otherwise).
Names, descriptions and schemas were written by the server and are shown as data.
Pattern matches on what the server declares. They show what it says it can do, not what it does.