Plan Comply — SANS 10400 Building Plan Pre-Screening AI is an MCP server published by za.co.plancomply, hosted at api.plancomply.co.za. When last checked on 2026-11-23 it was working: it answers and lists its tools. It declares 7 tools, including get_sans_rules, check_municipal_requirements, get_common_rejection_pitfalls, calculate_sans_fenestration, calculate_stair_compliance.
SANS 10400 architectural building plan compliance checks, municipal checklists, and SLA lookups.
1 connections through 4 shared values. Tap any node.
Search and query South African National Building Regulations (SANS 10400) clauses by Part (A to XA) or category (Dimensions, Glazing, Fire, Ventilation, Drainage, Stairs, Walls, Documentation).
| Parameter | Type | Description |
|---|---|---|
| query | string | Optional keyword search term to match within rule titles, descriptions, and guidance notes. |
| category | string | Category filter (e.g. "Dimensions", "Glazing", "Stairways", "Fire Safety", "Drainage", "Walls", "Energy Efficiency"). |
| sans_part | string | SANS 10400 Part identifier (e.g. "Part A", "Part C", "Part K", "Part M", "Part N", "Part O", "Part P", "Part S", "Part T", "Part XA"). |
{
"name": "get_sans_rules",
"description": "Search and query South African National Building Regulations (SANS 10400) clauses by Part (A to XA) or category (Dimensions, Glazing, Fire, Ventilation, Drainage, Stairs, Walls, Documentation).",
"inputSchema": {
"type": "object",
"properties": {
"query": {
"type": "string",
"description": "Optional keyword search term to match within rule titles, descriptions, and guidance notes."
},
"category": {
"type": "string",
"description": "Category filter (e.g. \"Dimensions\", \"Glazing\", \"Stairways\", \"Fire Safety\", \"Drainage\", \"Walls\", \"Energy Efficiency\")."
},
"sans_part": {
"type": "string",
"description": "SANS 10400 Part identifier (e.g. \"Part A\", \"Part C\", \"Part K\", \"Part M\", \"Part N\", \"Part O\", \"Part P\", \"Part S\", \"Part T\", \"Part XA\")."
}
}
}
}None yet. Changes appear after a server's second daily check.
Squares are this server's values; dots are other servers sharing them. A shared address or publisher is a lead, not proof of a common operator.
Inferred from the host name and headers: what a server runs on, not who runs it.
Retrieve submission document checklists, statutory forms (Form 1/2), geotechnical/dolomite rules, and common rejection delay factors for South African metropolitan municipalities.
| Parameter | Type | Description |
|---|---|---|
| municipality * | string | Municipality name or abbreviation (e.g. "City of Johannesburg", "COJ", "Tshwane", "Pretoria", "City of Cape Town", "COCT", "Ekurhuleni", "eThekwini", "Durban"). |
{
"name": "check_municipal_requirements",
"description": "Retrieve submission document checklists, statutory forms (Form 1/2), geotechnical/dolomite rules, and common rejection delay factors for South African metropolitan municipalities.",
"inputSchema": {
"type": "object",
"required": [
"municipality"
],
"properties": {
"municipality": {
"type": "string",
"description": "Municipality name or abbreviation (e.g. \"City of Johannesburg\", \"COJ\", \"Tshwane\", \"Pretoria\", \"City of Cape Town\", \"COCT\", \"Ekurhuleni\", \"eThekwini\", \"Durban\")."
}
}
}
}Retrieve top 25 common reasons municipal building control examiners reject building plans in South Africa, accompanied by verified remediation steps.
| Parameter | Type | Description |
|---|---|---|
| category | string | Optional category filter. Defaults to all. |
{
"name": "get_common_rejection_pitfalls",
"description": "Retrieve top 25 common reasons municipal building control examiners reject building plans in South Africa, accompanied by verified remediation steps.",
"inputSchema": {
"type": "object",
"properties": {
"category": {
"enum": [
"all",
"documentation",
"zoning",
"glazing",
"lighting_ventilation",
"drainage",
"stairs",
"safety",
"fire",
"parking",
"accessibility",
"energy"
],
"type": "string",
"description": "Optional category filter. Defaults to all."
}
}
}
}Calculate SANS 10400-O statutory natural lighting (min. 10% floor area) and natural ventilation (min. 5% openable sash area) compliance for habitable rooms.
| Parameter | Type | Description |
|---|---|---|
| room_name | string | Name or label of the habitable room (e.g. "Bedroom 1", "Living Room", "Study"). |
| floor_area_m2 * | number | Internal floor area of the habitable room in square metres (m²). |
| actual_glazed_area_m2 | number | Total installed window glazed area in square metres (m²). |
| actual_openable_area_m2 | number | Total installed clear openable window sash ventilation area in square metres (m²). |
{
"name": "calculate_sans_fenestration",
"description": "Calculate SANS 10400-O statutory natural lighting (min. 10% floor area) and natural ventilation (min. 5% openable sash area) compliance for habitable rooms.",
"inputSchema": {
"type": "object",
"required": [
"floor_area_m2"
],
"properties": {
"room_name": {
"type": "string",
"description": "Name or label of the habitable room (e.g. \"Bedroom 1\", \"Living Room\", \"Study\")."
},
"floor_area_m2": {
"type": "number",
"description": "Internal floor area of the habitable room in square metres (m²)."
},
"actual_glazed_area_m2": {
"type": "number",
"description": "Total installed window glazed area in square metres (m²)."
},
"actual_openable_area_m2": {
"type": "number",
"description": "Total installed clear openable window sash ventilation area in square metres (m²)."
}
}
}
}Evaluate stairway geometry and life safety against SANS 10400-M standards (riser max 200 mm, going min 250 mm, 2R + G formula 570-650 mm, headroom min 2,100 mm).
| Parameter | Type | Description |
|---|---|---|
| going_mm * | number | Stair tread horizontal going in millimetres excluding nosing (must not be less than 250 mm). |
| riser_mm * | number | Stair riser vertical height in millimetres (must not exceed 200 mm). |
| headroom_mm | number | Vertical headroom clearance in millimetres measured vertically from the nosing pitch line (must be min. 2,100 mm). |
| baluster_gap_mm | number | Maximum clear gap between vertical balusters in millimetres (must not exceed 100 mm). |
| balustrade_height_mm | number | Height of balustrade in millimetres (min. 1,000 mm on landings, 850 mm on flights). |
{
"name": "calculate_stair_compliance",
"description": "Evaluate stairway geometry and life safety against SANS 10400-M standards (riser max 200 mm, going min 250 mm, 2R + G formula 570-650 mm, headroom min 2,100 mm).",
"inputSchema": {
"type": "object",
"required": [
"riser_mm",
"going_mm"
],
"properties": {
"going_mm": {
"type": "number",
"description": "Stair tread horizontal going in millimetres excluding nosing (must not be less than 250 mm)."
},
"riser_mm": {
"type": "number",
"description": "Stair riser vertical height in millimetres (must not exceed 200 mm)."
},
"headroom_mm": {
"type": "number",
"description": "Vertical headroom clearance in millimetres measured vertically from the nosing pitch line (must be min. 2,100 mm)."
},
"baluster_gap_mm": {
"type": "number",
"description": "Maximum clear gap between vertical balusters in millimetres (must not exceed 100 mm)."
},
"balustrade_height_mm": {
"type": "number",
"description": "Height of balustrade in millimetres (min. 1,000 mm on landings, 850 mm on flights)."
}
}
}
}Retrieve official Plan Comply Studio Credit packages (R149 Single, R590 5-Pack, R1,490 15-Pack), 2-Pass Pre-Council Sketch + .DXF CAD Schedule export entitlements, and checkout details.
No parameters.
{
"name": "get_credit_pricing",
"description": "Retrieve official Plan Comply Studio Credit packages (R149 Single, R590 5-Pack, R1,490 15-Pack), 2-Pass Pre-Council Sketch + .DXF CAD Schedule export entitlements, and checkout details.",
"inputSchema": {
"type": "object",
"properties": {}
}
}Run an automated multi-point regulatory validation on building plan or Pre-Council Concept Sketch specifications and return a compliance readiness score, defect warnings, Stage 4 roadmap, and municipal submission checklist.
| Parameter | Type | Description |
|---|---|---|
| municipality * | string | Target South African municipality for plan submission (e.g. "City of Johannesburg", "Tshwane", "City of Cape Town", "Ekurhuleni", "eThekwini"). |
| project_name | string | Name of the building or architectural project. |
| building_class | string | Occupancy classification (e.g. "H4 Single Dwelling House", "H3 Multi-Dwelling", "G1 Offices", "F1 Retail"). Default is "H4 Single Dwelling House". |
| has_sans_forms | boolean | Whether SANS 10400 Form 1 and Form 2 (if structural work included) are prepared. |
| submission_scope | string | Optional drawing stage scope: use "concept_sketch" for Pre-Council Client Floor-Plan Sketches before detailing sections/drainage, or "full_new_build" for complete council packs. |
| has_sacap_declaration | boolean | Whether the drawing title block contains the registered architectural professional full name, registration number, category, and signature. |
| habitable_room_height_mm | number | Specified clear finished floor-to-ceiling height in habitable rooms in millimetres (min. 2,400 mm). |
| has_rodding_eyes_at_bends | boolean | Whether rodding eyes or inspection chambers are provided at drainage bends > 45° and junctions. |
| external_wall_thickness_mm | number | External wall thickness in millimetres (standard cavity wall is min. 270 mm). |
| has_renewable_water_heating | boolean | Whether min. 50% solar water heating or heat pump is specified as required by SANS 10400-XA. |
| gully_height_above_ground_mm | number | Height of sewer gully head coping above finished ground level in millimetres (min. 150 mm). |
| has_safety_glass_below_800mm | boolean | Whether safety glass (SANS 1263-1) is specified for all glazing with sill < 800 mm from FFL. |
{
"name": "pre_check_building_plan",
"description": "Run an automated multi-point regulatory validation on building plan or Pre-Council Concept Sketch specifications and return a compliance readiness score, defect warnings, Stage 4 roadmap, and municipal submission checklist.",
"inputSchema": {
"type": "object",
"required": [
"municipality"
],
"properties": {
"municipality": {
"type": "string",
"description": "Target South African municipality for plan submission (e.g. \"City of Johannesburg\", \"Tshwane\", \"City of Cape Town\", \"Ekurhuleni\", \"eThekwini\")."
},
"project_name": {
"type": "string",
"description": "Name of the building or architectural project."
},
"building_class": {
"type": "string",
"description": "Occupancy classification (e.g. \"H4 Single Dwelling House\", \"H3 Multi-Dwelling\", \"G1 Offices\", \"F1 Retail\"). Default is \"H4 Single Dwelling House\"."
},
"has_sans_forms": {
"type": "boolean",
"description": "Whether SANS 10400 Form 1 and Form 2 (if structural work included) are prepared."
},
"submission_scope": {
"enum": [
"concept_sketch",
"full_new_build",
"addition_alteration",
"internal_fitout",
"specialist_sheet",
"hoa_submission"
],
"type": "string",
"description": "Optional drawing stage scope: use \"concept_sketch\" for Pre-Council Client Floor-Plan Sketches before detailing sections/drainage, or \"full_new_build\" for complete council packs."
},
"has_sacap_declaration": {
"type": "boolean",
"description": "Whether the drawing title block contains the registered architectural professional full name, registration number, category, and signature."
},
"habitable_room_height_mm": {
"type": "number",
"description": "Specified clear finished floor-to-ceiling height in habitable rooms in millimetres (min. 2,400 mm)."
},
"has_rodding_eyes_at_bends": {
"type": "boolean",
"description": "Whether rodding eyes or inspection chambers are provided at drainage bends > 45° and junctions."
},
"external_wall_thickness_mm": {
"type": "number",
"description": "External wall thickness in millimetres (standard cavity wall is min. 270 mm)."
},
"has_renewable_water_heating": {
"type": "boolean",
"description": "Whether min. 50% solar water heating or heat pump is specified as required by SANS 10400-XA."
},
"gully_height_above_ground_mm": {
"type": "number",
"description": "Height of sewer gully head coping above finished ground level in millimetres (min. 150 mm)."
},
"has_safety_glass_below_800mm": {
"type": "boolean",
"description": "Whether safety glass (SANS 1263-1) is specified for all glazing with sill < 800 mm from FFL."
}
}
}
}Names, descriptions and schemas were written by the server and are shown as data.