RackArchitect MCP is an MCP server published by io.github.itAlex240, hosted at mcp.rackarchitect.dev. When last checked on 2026-11-23 it was working: it answers and lists its tools. It declares 12 tools, including search_catalog, get_device_blueprint, define_custom_blueprint, init_rack, mount_equipment.
Hosted Remote MCP & 3D/2D Rack-as-Code planner, 5-stage validator, CAD SVG/BOM & STL generator.
1 connections through 5 shared values. Tap any node.
Inferred from the host name and headers: what a server runs on, not who runs it.
Search and filter the local hardware catalog to discover compatible rackmount devices, modular carriers, and sub-modules before mounting. All supplied filters combine with logical AND: 'form_factor' and its alias 'mount_type' accept width shorthands '10inch', '19inch', and '6inch' that match both direct rackmount gear and modular carriers, 'accepted_slot_type' matches both carrier bays and compatible sub-modules, and 'max_depth_mm' bounds chassis depth excluding plug clearance. Returns all matches from the bounded catalog in one unpaginated response sorted in deterministic registration order, with built-in blueprints followed by custom blueprints. Call with no arguments to list the full catalog; use get_device_blueprint to inspect expanded port coordinates for a known slug, or define_custom_blueprint to register unlisted hardware.
| Parameter | Type | Description |
|---|---|---|
| query | string | Optional case-insensitive substring filter matching slug, manufacturer, or model name (omit to match all). |
| category |
None yet. Changes appear after a server's second daily check.
Squares are this server's values; dots are other servers sharing them. A shared address or publisher is a lead, not proof of a common operator.
| string |
| Functional hardware category filter (e.g., "switch", "router", "ups", "pdu", "patch-panel", "modular-carrier", "mini-pc", "sbc"). |
| mount_type | string | Optional alias for form_factor to filter by physical mounting style ("rackmount-10", "rackmount-19", "rackmount-6", "sub-module", or "shelf-standing"); combined with logical AND if both are provided. |
| form_factor | string | Primary rack width or mounting form-factor filter (shorthands "10inch", "19inch", and "6inch" match both direct rackmount equipment and modular carriers of that width). |
| max_depth_mm | number | Maximum allowed chassis depth in millimeters (inclusive upper bound). |
| accepted_slot_type | string | Sub-module slot compatibility token matching either a sub-module slot_compatibility or a carrier slot accepted_slot_type (e.g., "mini-pc-1liter", "sbc-rpi5", "standard-keystone"). |
| min_poe_budget_watts | number | Minimum required PSE PoE output power budget in watts (inclusive lower bound). |
{
"name": "search_catalog",
"title": "Search Hardware Blueprint Catalog",
"description": "Search and filter the local hardware catalog to discover compatible rackmount devices, modular carriers, and sub-modules before mounting. All supplied filters combine with logical AND: 'form_factor' and its alias 'mount_type' accept width shorthands '10inch', '19inch', and '6inch' that match both direct rackmount gear and modular carriers, 'accepted_slot_type' matches both carrier bays and compatible sub-modules, and 'max_depth_mm' bounds chassis depth excluding plug clearance. Returns all matches from the bounded catalog in one unpaginated response sorted in deterministic registration order, with built-in blueprints followed by custom blueprints. Call with no arguments to list the full catalog; use get_device_blueprint to inspect expanded port coordinates for a known slug, or define_custom_blueprint to register unlisted hardware.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"properties": {
"query": {
"type": "string",
"maxLength": 200,
"description": "Optional case-insensitive substring filter matching slug, manufacturer, or model name (omit to match all)."
},
"category": {
"enum": [
"switch",
"router",
"compute-node",
"mini-pc",
"sbc",
"nas",
"patch-panel",
"pdu",
"ups",
"modular-carrier",
"brush-panel",
"blanking-panel",
"blank-panel",
"shelf",
"keystone-module"
],
"type": "string",
"description": "Functional hardware category filter (e.g., \"switch\", \"router\", \"ups\", \"pdu\", \"patch-panel\", \"modular-carrier\", \"mini-pc\", \"sbc\")."
},
"mount_type": {
"enum": [
"rackmount-19",
"rackmount-10",
"rackmount-6",
"sub-module",
"shelf-standing",
"10inch",
"19inch",
"6inch"
],
"type": "string",
"description": "Optional alias for form_factor to filter by physical mounting style (\"rackmount-10\", \"rackmount-19\", \"rackmount-6\", \"sub-module\", or \"shelf-standing\"); combined with logical AND if both are provided."
},
"form_factor": {
"enum": [
"rackmount-19",
"rackmount-10",
"rackmount-6",
"sub-module",
"shelf-standing",
"10inch",
"19inch",
"6inch"
],
"type": "string",
"description": "Primary rack width or mounting form-factor filter (shorthands \"10inch\", \"19inch\", and \"6inch\" match both direct rackmount equipment and modular carriers of that width)."
},
"max_depth_mm": {
"type": "number",
"maximum": 2000,
"description": "Maximum allowed chassis depth in millimeters (inclusive upper bound).",
"exclusiveMinimum": 0
},
"accepted_slot_type": {
"type": "string",
"maxLength": 100,
"minLength": 1,
"description": "Sub-module slot compatibility token matching either a sub-module slot_compatibility or a carrier slot accepted_slot_type (e.g., \"mini-pc-1liter\", \"sbc-rpi5\", \"standard-keystone\")."
},
"min_poe_budget_watts": {
"type": "number",
"maximum": 100000,
"minimum": 0,
"description": "Minimum required PSE PoE output power budget in watts (inclusive lower bound)."
}
}
},
"outputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"status",
"summary",
"data",
"issues"
],
"properties": {
"data": {
"type": "object",
"required": [
"count",
"blueprints"
],
"properties": {
"count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Total number of catalog blueprints matching all supplied filter criteria."
},
"blueprints": {
"type": "array",
"items": {
"type": "object",
"required": [
"slug",
"manufacturer",
"model",
"category",
"mount_type",
"u_height",
"width_mm",
"height_mm",
"depth_mm",
"weight_grams",
"electrical_role",
"max_system_watts",
"poe_budget_watts",
"slot_compatibility",
"slots",
"port_count"
],
"properties": {
"slug": {
"type": "string",
"description": "Unique lowercase kebab-case hardware blueprint slug."
},
"model": {
"type": "string",
"description": "Hardware model name."
},
"slots": {
"type": "array",
"items": {
"type": "object",
"required": [
"slot_id",
"accepted_slot_type",
"max_dimensions_mm"
],
"properties": {
"slot_id": {
"type": "string",
"description": "Carrier bay slot identifier."
},
"max_dimensions_mm": {
"type": "object",
"required": [
"width",
"height",
"depth"
],
"properties": {
"depth": {
"type": "number",
"maximum": 2000,
"description": "Maximum allowed child depth in mm.",
"exclusiveMinimum": 0
},
"width": {
"type": "number",
"maximum": 2000,
"description": "Maximum allowed child width in mm.",
"exclusiveMinimum": 0
},
"height": {
"type": "number",
"maximum": 3000,
"description": "Maximum allowed child height in mm.",
"exclusiveMinimum": 0
}
},
"description": "Maximum internal bounding dimensions of a carrier slot in mm.",
"additionalProperties": false
},
"accepted_slot_type": {
"type": "string",
"description": "Accepted child sub-module compatibility token."
}
},
"additionalProperties": false
},
"description": "Available carrier bays when mount_type is \"modular-carrier\"."
},
"category": {
"enum": [
"switch",
"router",
"compute-node",
"mini-pc",
"sbc",
"nas",
"patch-panel",
"pdu",
"ups",
"modular-carrier",
"brush-panel",
"blanking-panel",
"blank-panel",
"shelf",
"keystone-module"
],
"type": "string",
"description": "Primary functional category of the hardware unit."
},
"depth_mm": {
"type": "number",
"description": "Chassis depth in millimeters."
},
"u_height": {
"type": "number",
"description": "Nominal height in Rack Units (U)."
},
"width_mm": {
"type": "number",
"description": "Chassis width in millimeters."
},
"height_mm": {
"type": "number",
"description": "Chassis height in millimeters."
},
"mount_type": {
"enum": [
"rackmount-19",
"rackmount-10",
"rackmount-6",
"sub-module",
"shelf-standing"
],
"type": "string",
"description": "Physical form factor and mounting mechanism."
},
"port_count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Total number of expanded physical ports."
},
"manufacturer": {
"type": "string",
"description": "Hardware manufacturer name."
},
"weight_grams": {
"type": "number",
"description": "Device mass in grams."
},
"electrical_role": {
"enum": [
"consumer",
"pse-switch",
"pdu",
"ups",
"passive"
],
"type": "string",
"description": "Role in the electrical and PoE Directed Acyclic Graph (DAG)."
},
"max_system_watts": {
"type": "number",
"description": "Peak system power consumption in watts."
},
"poe_budget_watts": {
"type": "number",
"description": "Available PSE PoE output budget in watts (0 if non-PSE)."
},
"slot_compatibility": {
"type": [
"string",
"null"
],
"description": "Sub-module slot compatibility token, or null for rackmount equipment."
}
},
"description": "Compact hardware blueprint summary returned by search_catalog.",
"additionalProperties": {}
},
"description": "Matching hardware blueprint summary records."
}
},
"description": "Catalog search result payload.",
"additionalProperties": {}
},
"issues": {
"type": "array",
"items": {
"type": "object",
"required": [
"code",
"severity",
"affected_instances",
"message",
"remediation_suggestions"
],
"properties": {
"code": {
"enum": [
"CHASSIS_COLLISION",
"PLUG_CLEARANCE_COLLISION",
"FRONT_DOOR_COLLISION",
"SLOT_DIMENSION_OVERFLOW",
"SLOT_INCOMPATIBLE",
"OUT_OF_RACK_BOUNDS",
"BLUEPRINT_NOT_FOUND",
"PORT_NOT_FOUND",
"PORT_ALREADY_OCCUPIED",
"CONNECTOR_INCOMPATIBLE",
"SIGNAL_PROTOCOL_INCOMPATIBLE",
"SPEED_MISMATCH",
"POE_BUDGET_EXCEEDED",
"POE_CLASS_EXCEEDED",
"UPS_OVERLOAD",
"UNPOWERED_DEVICE",
"TOP_HEAVY_RACK",
"NO_FRONT_TO_REAR_PORTAL",
"THERMAL_AIRFLOW_CONFLICT",
"THERMAL_HOTSPOT_STACKING",
"ACOUSTIC_NOISE_HIGH"
],
"type": "string",
"description": "Machine-readable deterministic validation diagnostic code."
},
"stage": {
"type": "integer",
"maximum": 5,
"minimum": 1,
"description": "Validation pipeline stage (1..5) that produced this finding."
},
"message": {
"type": "string",
"description": "Detailed engineering explanation with exact millimeter/watt figures."
},
"u_range": {
"type": "array",
"items": [
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
}
],
"maxItems": 2,
"minItems": 2,
"description": "Inclusive [start_u, end_u] range where the issue occurs.",
"additionalItems": false
},
"severity": {
"enum": [
"ERROR",
"WARNING",
"INFO"
],
"type": "string",
"description": "Severity level of the engineering constraint diagnostic."
},
"affected_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Device instance IDs involved in this diagnostic issue."
},
"remediation_actions": {
"type": "array",
"items": {
"type": "object",
"required": [
"action_type",
"description"
],
"properties": {
"action_type": {
"enum": [
"move_device",
"change_cable_type",
"connect_power",
"disconnect_cable",
"redistribute_poe",
"add_portal_gap",
"change_rack_depth"
],
"type": "string",
"description": "Recommended self-correction operation category."
},
"description": {
"type": "string",
"description": "Human- and agent-readable explanation of the remediation step."
},
"suggested_face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"target_cable_id": {
"type": "string",
"description": "Cable connection cable_id targeted by this remediation action."
},
"target_instance_id": {
"type": "string",
"description": "Device instance_id targeted by this remediation action."
},
"suggested_cable_type": {
"type": "string",
"description": "Suggested replacement cable_type (e.g. angled plug or higher speed grade)."
},
"suggested_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"exclusiveMinimum": 0
},
"description": "Candidate 1-indexed U positions that resolve the spatial conflict."
}
},
"description": "Structured self-correction action for autonomous agent remediation.",
"additionalProperties": false
},
"description": "Optional machine-actionable remediation descriptors."
},
"remediation_suggestions": {
"type": "array",
"items": {
"type": "string"
},
"minItems": 1,
"description": "Actionable self-correction instructions for the calling LLM agent."
}
},
"description": "Single validation finding with deterministic self-correction feedback.",
"additionalProperties": false
},
"description": "Structured diagnostic findings (ERROR, WARNING, INFO) with actionable remediation_suggestions."
},
"status": {
"enum": [
"VALID",
"INVALID"
],
"type": "string",
"description": "Deterministic execution outcome: \"VALID\" when the operation succeeded with 0 validation errors; \"INVALID\" when precondition or engineering validation errors are present in issues[]."
},
"summary": {
"type": "string",
"description": "Concise human- and agent-readable summary of the tool result and validation status."
}
},
"additionalProperties": false
},
"annotations": {
"title": "Search Hardware Blueprint Catalog",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Retrieve the complete hardware specification, millimeter port coordinates, electrical and PoE ratings, and carrier slot geometry for a single catalog blueprint. The 'slug' parameter requires a case-sensitive exact match in lowercase kebab-case vendor-model-variant format against the built-in or session custom catalog; partial substrings or uppercase characters do not match. Returns the full blueprint in one unpaginated payload with repeating port_groups pre-expanded into up to 256 flat ports[] entries, or returns status 'INVALID' with a BLUEPRINT_NOT_FOUND issue and candidate slugs instead of throwing. Use when you already know the target slug and need exact port_id or slot_id values for mount_equipment or connect_cables; use search_catalog instead to discover unknown slugs by criteria.
| Parameter | Type | Description |
|---|---|---|
| slug * | string | Exact lowercase kebab-case hardware catalog blueprint slug to retrieve (discoverable via search_catalog). |
{
"name": "get_device_blueprint",
"title": "Retrieve Hardware Device Blueprint Details",
"description": "Retrieve the complete hardware specification, millimeter port coordinates, electrical and PoE ratings, and carrier slot geometry for a single catalog blueprint. The 'slug' parameter requires a case-sensitive exact match in lowercase kebab-case vendor-model-variant format against the built-in or session custom catalog; partial substrings or uppercase characters do not match. Returns the full blueprint in one unpaginated payload with repeating port_groups pre-expanded into up to 256 flat ports[] entries, or returns status 'INVALID' with a BLUEPRINT_NOT_FOUND issue and candidate slugs instead of throwing. Use when you already know the target slug and need exact port_id or slot_id values for mount_equipment or connect_cables; use search_catalog instead to discover unknown slugs by criteria.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"slug"
],
"properties": {
"slug": {
"type": "string",
"maxLength": 100,
"minLength": 1,
"description": "Exact lowercase kebab-case hardware catalog blueprint slug to retrieve (discoverable via search_catalog)."
}
}
},
"outputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"status",
"summary",
"data",
"issues"
],
"properties": {
"data": {
"type": "object",
"properties": {
"blueprint": {
"type": "object",
"required": [
"slug",
"manufacturer",
"model",
"category",
"mount_type",
"geometry",
"power_and_thermal",
"port_groups",
"ports",
"slots",
"visuals",
"printable_metadata"
],
"properties": {
"slug": {
"type": "string",
"pattern": "^[a-z0-9-]+$",
"maxLength": 100,
"minLength": 1,
"description": "Unique lowercase kebab-case hardware identifier (vendor-model-variant)."
},
"model": {
"type": "string",
"maxLength": 160,
"minLength": 1,
"description": "Hardware model name or part number."
},
"ports": {
"type": "array",
"items": {
"type": "object",
"required": [
"port_id",
"label",
"face",
"connector_type",
"direction",
"capabilities",
"coordinates"
],
"properties": {
"face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"label": {
"type": "string",
"maxLength": 160,
"minLength": 1,
"description": "Human-readable silk-screened port label."
},
"port_id": {
"type": "string",
"maxLength": 128,
"minLength": 1,
"description": "Unique identifier of the port within the device."
},
"direction": {
"enum": [
"input",
"output",
"bidirectional"
],
"type": "string",
"description": "Signal or electrical power flow direction."
},
"coordinates": {
"type": "object",
"required": [
"x_mm",
"y_mm",
"orientation"
],
"properties": {
"x_mm": {
"type": "number",
"maximum": 2000,
"minimum": -2000,
"description": "Horizontal offset in mm from the bottom-left corner of the face."
},
"y_mm": {
"type": "number",
"maximum": 3000,
"minimum": -3000,
"description": "Vertical offset in mm from the bottom-left corner of the face."
},
"orientation": {
"enum": [
"upright",
"inverted",
"left",
"right"
],
"type": "string",
"default": "upright",
"description": "Physical orientation of the connector latch/keyway."
}
},
"description": "Local 2D coordinates on the device face in millimeters.",
"additionalProperties": false
},
"capabilities": {
"type": "array",
"items": {
"enum": [
"100base-tx",
"1000base-t",
"2500base-t",
"5gbase-t",
"10gbase-t",
"10gbase-sr",
"10gbase-lr",
"10gbase-dac",
"25gbase-dac",
"poe-out",
"poe+",
"poe-out-af",
"poe-out-at",
"poe-out-bt-type3",
"poe-out-bt-type4",
"poe-in-af",
"poe-in-at",
"poe-in-bt-type3",
"poe-in-bt-type4",
"ac-mains",
"dc-power",
"usb-pd",
"usb-3.0",
"usb-3.1",
"audio-analog",
"serial-rs232",
"passthrough-coupler"
],
"type": "string",
"description": "Supported electrical, optical, or PoE protocol capability."
},
"default": [],
"maxItems": 32,
"description": "Electrical, optical, or PoE capabilities supported by this port."
},
"connector_type": {
"enum": [
"rj45",
"rj45-serial-console",
"sfp-plus",
"iec-c13",
"iec-c14",
"schuko-cee7",
"dc-5525",
"usb-c",
"usb-a",
"audio-35mm"
],
"type": "string",
"description": "Physical connector interface type."
},
"is_passthrough_coupler": {
"type": "boolean",
"description": "True if this port is a passive front-to-rear feedthrough coupler."
}
},
"description": "Explicit physical port definition with local millimeter coordinates.",
"additionalProperties": false
},
"default": [],
"maxItems": 256,
"description": "Explicit physical ports with local face millimeter coordinates."
},
"slots": {
"type": "array",
"items": {
"type": "object",
"required": [
"slot_id",
"accepted_slot_type",
"offset_mm",
"max_dimensions_mm"
],
"properties": {
"slot_id": {
"type": "string",
"maxLength": 100,
"minLength": 1,
"description": "Unique slot identifier within the carrier."
},
"offset_mm": {
"type": "object",
"required": [
"x",
"y",
"z"
],
"properties": {
"x": {
"type": "number",
"maximum": 2000,
"minimum": -2000,
"description": "Local X offset from carrier origin in mm."
},
"y": {
"type": "number",
"maximum": 3000,
"minimum": -3000,
"description": "Local Y offset from carrier origin in mm."
},
"z": {
"type": "number",
"default": 0,
"maximum": 2000,
"minimum": -2000,
"description": "Local Z offset from carrier origin in mm."
}
},
"description": "Local 3D offset of a sub-module slot relative to its parent carrier.",
"additionalProperties": false
},
"max_dimensions_mm": {
"type": "object",
"required": [
"width",
"height",
"depth"
],
"properties": {
"depth": {
"type": "number",
"maximum": 2000,
"description": "Maximum allowed child depth in mm.",
"exclusiveMinimum": 0
},
"width": {
"type": "number",
"maximum": 2000,
"description": "Maximum allowed child width in mm.",
"exclusiveMinimum": 0
},
"height": {
"type": "number",
"maximum": 3000,
"description": "Maximum allowed child height in mm.",
"exclusiveMinimum": 0
}
},
"description": "Maximum internal bounding dimensions of a carrier slot in mm.",
"additionalProperties": false
},
"accepted_slot_type": {
"type": "string",
"maxLength": 100,
"minLength": 1,
"description": "Required child slot_compatibility token (e.g. \"mini-pc-1liter\")."
}
},
"description": "Sub-U carrier bay specification for modular child devices.",
"additionalProperties": false
},
"default": [],
"maxItems": 32,
"description": "Sub-module carrier bays when mount_type is \"modular-carrier\"."
},
"visuals": {
"type": "object",
"default": {
"stl_mesh_path": null,
"material_preset": "matte-black-steel",
"has_oled_display": false,
"chassis_color_hex": "#E5E7EB"
},
"required": [
"chassis_color_hex",
"material_preset",
"has_oled_display",
"stl_mesh_path"
],
"properties": {
"stl_mesh_path": {
"anyOf": [
{
"type": "string",
"maxLength": 512
},
{
"type": "null"
}
],
"default": null,
"description": "Optional relative path to custom 3D mesh (.stl/.glb)."
},
"material_preset": {
"enum": [
"matte-black-steel",
"coated-aluminum",
"3d-printed-petg",
"3d-printed-abs",
"polycarbonate"
],
"type": "string",
"default": "matte-black-steel",
"description": "Surface material shader preset for 3D procedural rendering."
},
"has_oled_display": {
"type": "boolean",
"default": false,
"description": "True if the front panel includes a status OLED screen."
},
"chassis_color_hex": {
"type": "string",
"default": "#E5E7EB",
"pattern": "^#[0-9A-Fa-f]{6}$",
"description": "Primary chassis hex color code."
}
},
"description": "Visual rendering metadata for 2D SVG and 3D WebGL pipelines.",
"additionalProperties": false
},
"category": {
"enum": [
"switch",
"router",
"compute-node",
"mini-pc",
"sbc",
"nas",
"patch-panel",
"pdu",
"ups",
"modular-carrier",
"brush-panel",
"blanking-panel",
"blank-panel",
"shelf",
"keystone-module"
],
"type": "string",
"description": "Primary functional category of the hardware unit."
},
"geometry": {
"type": "object",
"required": [
"u_height",
"width_mm",
"height_mm",
"depth_mm",
"ear_mount_style",
"front_protrusion_mm",
"rear_protrusion_mm",
"weight_grams"
],
"properties": {
"depth_mm": {
"type": "number",
"maximum": 2000,
"description": "Physical chassis depth in millimeters along the Z-axis (max 2000mm).",
"exclusiveMinimum": 0
},
"u_height": {
"type": "number",
"maximum": 60,
"minimum": 0,
"description": "Nominal height in Rack Units (1U = 44.45mm, max 60U)."
},
"width_mm": {
"type": "number",
"maximum": 1000,
"description": "Physical chassis body width in millimeters (max 1000mm).",
"exclusiveMinimum": 0
},
"height_mm": {
"type": "number",
"maximum": 3000,
"description": "Physical chassis height in millimeters (max 3000mm).",
"exclusiveMinimum": 0
},
"weight_grams": {
"type": "number",
"default": 0,
"maximum": 500000,
"minimum": 0,
"description": "Total device mass in grams for Center of Gravity calculation."
},
"ear_mount_style": {
"enum": [
"included-19inch-ears",
"included-10inch-ears",
"included-6inch-ears",
"flush-front",
"recessed-20mm",
"sub-module-clip",
"rear-rail-mount",
"none"
],
"type": "string",
"default": "flush-front",
"description": "Mounting ear geometry relative to the vertical rack rails."
},
"rear_protrusion_mm": {
"type": "number",
"default": 0,
"maximum": 500,
"minimum": 0,
"description": "Protrusion behind depth_mm (fans, PSU handles) in mm."
},
"front_protrusion_mm": {
"type": "number",
"default": 0,
"maximum": 500,
"minimum": 0,
"description": "Protrusion in front of Z=0 (handles, ears, knobs) in mm."
},
"has_cable_pass_through": {
"type": "boolean",
"description": "True if cables can pass front-to-rear through this unit."
}
},
"description": "Physical 3D bounding dimensions and mass specification.",
"additionalProperties": false
},
"mount_type": {
"enum": [
"rackmount-19",
"rackmount-10",
"rackmount-6",
"sub-module",
"shelf-standing"
],
"type": "string",
"description": "Physical form factor and mounting mechanism."
},
"description": {
"type": "string",
"maxLength": 2000,
"description": "Human-readable explanation of what the device is, its role in the rack, and its physical mounting method (e.g. native rack ears vs. 3D-printed carrier/cradle)."
},
"port_groups": {
"type": "array",
"items": {
"type": "object",
"required": [
"id_prefix",
"start_index",
"count",
"face",
"connector_type",
"direction",
"capabilities",
"orientation",
"grid"
],
"properties": {
"face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"grid": {
"type": "object",
"required": [
"origin_x_mm",
"origin_y_mm",
"columns",
"rows",
"pitch_x_mm",
"pitch_y_mm"
],
"properties": {
"rows": {
"type": "integer",
"maximum": 16,
"description": "Number of vertical port rows in the matrix (1..16).",
"exclusiveMinimum": 0
},
"columns": {
"type": "integer",
"maximum": 64,
"description": "Number of horizontal port columns in the matrix (1..64).",
"exclusiveMinimum": 0
},
"pitch_x_mm": {
"type": "number",
"maximum": 500,
"minimum": -500,
"description": "Horizontal center-to-center spacing between adjacent columns in mm."
},
"pitch_y_mm": {
"type": "number",
"maximum": 500,
"minimum": -500,
"description": "Vertical center-to-center spacing between adjacent rows in mm."
},
"origin_x_mm": {
"type": "number",
"maximum": 2000,
"minimum": -2000,
"description": "X coordinate of the first port (column 0) in mm."
},
"origin_y_mm": {
"type": "number",
"maximum": 3000,
"minimum": -3000,
"description": "Y coordinate of the first port (row 0) in mm."
}
},
"description": "2D grid layout parameters for automatic port matrix expansion.",
"additionalProperties": false
},
"count": {
"type": "integer",
"maximum": 128,
"description": "Total number of ports to generate in this group (1..128).",
"exclusiveMinimum": 0
},
"direction": {
"enum": [
"input",
"output",
"bidirectional"
],
"type": "string",
"description": "Signal or electrical power flow direction."
},
"id_prefix": {
"type": "string",
"maxLength": 64,
"minLength": 1,
"description": "Prefix for generated port_id values (e.g. \"eth\")."
},
"orientation": {
"enum": [
"upright",
"inverted",
"left",
"right"
],
"type": "string",
"default": "upright",
"description": "Physical orientation of the connector latch/keyway."
},
"start_index": {
"type": "integer",
"default": 1,
"maximum": 10000,
"minimum": 0,
"description": "Starting numeric suffix for generated port IDs (default: 1)."
},
"capabilities": {
"type": "array",
"items": {
"enum": [
"100base-tx",
"1000base-t",
"2500base-t",
"5gbase-t",
"10gbase-t",
"10gbase-sr",
"10gbase-lr",
"10gbase-dac",
"25gbase-dac",
"poe-out",
"poe+",
"poe-out-af",
"poe-out-at",
"poe-out-bt-type3",
"poe-out-bt-type4",
"poe-in-af",
"poe-in-at",
"poe-in-bt-type3",
"poe-in-bt-type4",
"ac-mains",
"dc-power",
"usb-pd",
"usb-3.0",
"usb-3.1",
"audio-analog",
"serial-rs232",
"passthrough-coupler"
],
"type": "string",
"description": "Supported electrical, optical, or PoE protocol capability."
},
"default": [],
"maxItems": 32,
"description": "Capabilities assigned to every port generated by this group."
},
"label_prefix": {
"type": "string",
"maxLength": 96,
"description": "Prefix for generated human-readable labels."
},
"connector_type": {
"enum": [
"rj45",
"rj45-serial-console",
"sfp-plus",
"iec-c13",
"iec-c14",
"schuko-cee7",
"dc-5525",
"usb-c",
"usb-a",
"audio-35mm"
],
"type": "string",
"description": "Physical connector interface type."
},
"is_passthrough_coupler": {
"type": "boolean",
"description": "True if generated ports are passive front-to-rear couplers."
}
},
"description": "Declarative port matrix macro expanded into flat PortDefinition items on load.",
"additionalProperties": false
},
"default": [],
"maxItems": 16,
"description": "Optional repeating port grid macros expanded into flat ports[] upon registration."
},
"manufacturer": {
"type": "string",
"maxLength": 160,
"minLength": 1,
"description": "Hardware manufacturer name."
},
"power_and_thermal": {
"type": "object",
"required": [
"electrical_role",
"idle_watts",
"max_system_watts",
"airflow"
],
"properties": {
"airflow": {
"enum": [
"front-to-rear",
"rear-to-front",
"side-to-side",
"passive-convection",
"none"
],
"type": "string",
"default": "passive-convection",
"description": "Primary thermal airflow path through the device chassis."
},
"idle_watts": {
"type": "number",
"default": 0,
"maximum": 100000,
"minimum": 0,
"description": "Idle power draw in watts."
},
"noise_db_a": {
"type": "number",
"maximum": 200,
"minimum": 0,
"description": "Acoustic noise emission in dB(A) at 1 meter distance."
},
"electrical_role": {
"enum": [
"consumer",
"pse-switch",
"pdu",
"ups",
"passive"
],
"type": "string",
"description": "Role in the electrical and PoE Directed Acyclic Graph (DAG)."
},
"max_system_watts": {
"type": "number",
"default": 0,
"maximum": 100000,
"minimum": 0,
"description": "Peak own system power consumption in watts (excluding PoE output)."
},
"poe_budget_watts": {
"type": "number",
"maximum": 100000,
"minimum": 0,
"description": "Maximum total PoE output power budget in watts for PSE switches."
},
"pdu_capacity_watts": {
"type": "number",
"maximum": 100000,
"description": "Maximum output load capacity in watts for PDU units.",
"exclusiveMinimum": 0
},
"ups_capacity_watts": {
"type": "number",
"maximum": 100000,
"description": "Maximum output load capacity in watts for UPS units.",
"exclusiveMinimum": 0
}
},
"description": "Electrical power consumption, PoE budget, thermal airflow, and acoustic dB(A) characteristics.",
"additionalProperties": false
},
"printable_metadata": {
"anyOf": [
{
"type": "object",
"required": [
"filament_grams",
"material_recommendation"
],
"properties": {
"fasteners": {
"type": "string",
"maxLength": 256,
"description": "Optional specification of required mounting screws and cage nuts."
},
"filament_grams": {
"type": "number",
"maximum": 50000,
"minimum": 0,
"description": "Estimated filament mass in grams."
},
"printables_url": {
"type": "string",
"pattern": "^https?:\\/\\/",
"maxLength": 512,
"description": "Optional HTTPS reference URL to an upstream 3D model repository."
},
"heat_set_inserts": {
"type": "string",
"maxLength": 256,
"description": "Optional specification of required brass heat-set inserts."
},
"material_recommendation": {
"type": "string",
"default": "PETG",
"maxLength": 128,
"description": "Recommended 3D printing filament material (e.g. \"PETG\", \"ABS\", \"ASA\")."
}
},
"additionalProperties": false
},
{
"type": "null"
}
],
"default": null,
"description": "3D printing fabrication metadata for printable modular carriers."
},
"slot_compatibility": {
"type": "string",
"maxLength": 100,
"description": "Slot compatibility token when mount_type is \"sub-module\"."
},
"is_passthrough_coupler": {
"type": "boolean",
"description": "True if the entire unit acts as a passive front-to-rear feedthrough patch panel."
}
},
"description": "Complete hardware blueprint specification with port_groups pre-expanded into flat ports[].",
"additionalProperties": false
},
"requested_slug": {
"type": "string",
"description": "Requested slug echoed when lookup fails with BLUEPRINT_NOT_FOUND."
}
},
"description": "Blueprint lookup result payload.",
"additionalProperties": {}
},
"issues": {
"type": "array",
"items": {
"type": "object",
"required": [
"code",
"severity",
"affected_instances",
"message",
"remediation_suggestions"
],
"properties": {
"code": {
"enum": [
"CHASSIS_COLLISION",
"PLUG_CLEARANCE_COLLISION",
"FRONT_DOOR_COLLISION",
"SLOT_DIMENSION_OVERFLOW",
"SLOT_INCOMPATIBLE",
"OUT_OF_RACK_BOUNDS",
"BLUEPRINT_NOT_FOUND",
"PORT_NOT_FOUND",
"PORT_ALREADY_OCCUPIED",
"CONNECTOR_INCOMPATIBLE",
"SIGNAL_PROTOCOL_INCOMPATIBLE",
"SPEED_MISMATCH",
"POE_BUDGET_EXCEEDED",
"POE_CLASS_EXCEEDED",
"UPS_OVERLOAD",
"UNPOWERED_DEVICE",
"TOP_HEAVY_RACK",
"NO_FRONT_TO_REAR_PORTAL",
"THERMAL_AIRFLOW_CONFLICT",
"THERMAL_HOTSPOT_STACKING",
"ACOUSTIC_NOISE_HIGH"
],
"type": "string",
"description": "Machine-readable deterministic validation diagnostic code."
},
"stage": {
"type": "integer",
"maximum": 5,
"minimum": 1,
"description": "Validation pipeline stage (1..5) that produced this finding."
},
"message": {
"type": "string",
"description": "Detailed engineering explanation with exact millimeter/watt figures."
},
"u_range": {
"type": "array",
"items": [
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
}
],
"maxItems": 2,
"minItems": 2,
"description": "Inclusive [start_u, end_u] range where the issue occurs.",
"additionalItems": false
},
"severity": {
"enum": [
"ERROR",
"WARNING",
"INFO"
],
"type": "string",
"description": "Severity level of the engineering constraint diagnostic."
},
"affected_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Device instance IDs involved in this diagnostic issue."
},
"remediation_actions": {
"type": "array",
"items": {
"type": "object",
"required": [
"action_type",
"description"
],
"properties": {
"action_type": {
"enum": [
"move_device",
"change_cable_type",
"connect_power",
"disconnect_cable",
"redistribute_poe",
"add_portal_gap",
"change_rack_depth"
],
"type": "string",
"description": "Recommended self-correction operation category."
},
"description": {
"type": "string",
"description": "Human- and agent-readable explanation of the remediation step."
},
"suggested_face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"target_cable_id": {
"type": "string",
"description": "Cable connection cable_id targeted by this remediation action."
},
"target_instance_id": {
"type": "string",
"description": "Device instance_id targeted by this remediation action."
},
"suggested_cable_type": {
"type": "string",
"description": "Suggested replacement cable_type (e.g. angled plug or higher speed grade)."
},
"suggested_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"exclusiveMinimum": 0
},
"description": "Candidate 1-indexed U positions that resolve the spatial conflict."
}
},
"description": "Structured self-correction action for autonomous agent remediation.",
"additionalProperties": false
},
"description": "Optional machine-actionable remediation descriptors."
},
"remediation_suggestions": {
"type": "array",
"items": {
"type": "string"
},
"minItems": 1,
"description": "Actionable self-correction instructions for the calling LLM agent."
}
},
"description": "Single validation finding with deterministic self-correction feedback.",
"additionalProperties": false
},
"description": "Structured diagnostic findings (ERROR, WARNING, INFO) with actionable remediation_suggestions."
},
"status": {
"enum": [
"VALID",
"INVALID"
],
"type": "string",
"description": "Deterministic execution outcome: \"VALID\" when the operation succeeded with 0 validation errors; \"INVALID\" when precondition or engineering validation errors are present in issues[]."
},
"summary": {
"type": "string",
"description": "Concise human- and agent-readable summary of the tool result and validation status."
}
},
"additionalProperties": false
},
"annotations": {
"title": "Retrieve Hardware Device Blueprint Details",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Validate and register a custom hardware blueprint into the active catalog so unlisted equipment can be mounted. Pass the entire specification inside the top-level 'blueprint' object: 'blueprint.slug' must use lowercase kebab-case, ports may combine explicit 'ports[]' with repeating 'port_groups[]' macros whose coordinates fit strictly within 'blueprint.geometry' without overlapping, and 'slots[]' applies only when 'mount_type' is 'modular-carrier' whereas 'slot_compatibility' applies to 'sub-module'. Persists YAML to the local custom-catalog folder in stdio mode or session memory on remote servers, overwrites same-slug custom entries without touching mounted rack state or undo history, and returns status 'INVALID' instead of throwing on validation errors. Use only after search_catalog confirms hardware is unlisted; use mount_equipment instead to place an already registered blueprint into the rack.
| Parameter | Type | Description |
|---|---|---|
| blueprint * | object | Complete custom hardware blueprint specification; ports may be defined via explicit ports[], repeating port_groups[] macros, or both. |
{
"name": "define_custom_blueprint",
"title": "Register Custom Hardware Blueprint",
"description": "Validate and register a custom hardware blueprint into the active catalog so unlisted equipment can be mounted. Pass the entire specification inside the top-level 'blueprint' object: 'blueprint.slug' must use lowercase kebab-case, ports may combine explicit 'ports[]' with repeating 'port_groups[]' macros whose coordinates fit strictly within 'blueprint.geometry' without overlapping, and 'slots[]' applies only when 'mount_type' is 'modular-carrier' whereas 'slot_compatibility' applies to 'sub-module'. Persists YAML to the local custom-catalog folder in stdio mode or session memory on remote servers, overwrites same-slug custom entries without touching mounted rack state or undo history, and returns status 'INVALID' instead of throwing on validation errors. Use only after search_catalog confirms hardware is unlisted; use mount_equipment instead to place an already registered blueprint into the rack.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"blueprint"
],
"properties": {
"blueprint": {
"type": "object",
"required": [
"slug",
"manufacturer",
"model",
"category",
"mount_type",
"geometry",
"power_and_thermal"
],
"properties": {
"slug": {
"type": "string",
"pattern": "^[a-z0-9-]+$",
"maxLength": 100,
"minLength": 1,
"description": "Unique lowercase kebab-case hardware identifier (vendor-model-variant)."
},
"model": {
"type": "string",
"maxLength": 160,
"minLength": 1,
"description": "Hardware model name or part number."
},
"ports": {
"type": "array",
"items": {
"type": "object",
"required": [
"port_id",
"label",
"face",
"connector_type",
"direction",
"coordinates"
],
"properties": {
"face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"label": {
"type": "string",
"maxLength": 160,
"minLength": 1,
"description": "Human-readable silk-screened port label."
},
"port_id": {
"type": "string",
"maxLength": 128,
"minLength": 1,
"description": "Unique identifier of the port within the device."
},
"direction": {
"enum": [
"input",
"output",
"bidirectional"
],
"type": "string",
"description": "Signal or electrical power flow direction."
},
"coordinates": {
"type": "object",
"required": [
"x_mm",
"y_mm"
],
"properties": {
"x_mm": {
"type": "number",
"maximum": 2000,
"minimum": -2000,
"description": "Horizontal offset in mm from the bottom-left corner of the face."
},
"y_mm": {
"type": "number",
"maximum": 3000,
"minimum": -3000,
"description": "Vertical offset in mm from the bottom-left corner of the face."
},
"orientation": {
"enum": [
"upright",
"inverted",
"left",
"right"
],
"type": "string",
"default": "upright",
"description": "Physical orientation of the connector latch/keyway."
}
},
"description": "Local 2D coordinates on the device face in millimeters."
},
"capabilities": {
"type": "array",
"items": {
"enum": [
"100base-tx",
"1000base-t",
"2500base-t",
"5gbase-t",
"10gbase-t",
"10gbase-sr",
"10gbase-lr",
"10gbase-dac",
"25gbase-dac",
"poe-out",
"poe+",
"poe-out-af",
"poe-out-at",
"poe-out-bt-type3",
"poe-out-bt-type4",
"poe-in-af",
"poe-in-at",
"poe-in-bt-type3",
"poe-in-bt-type4",
"ac-mains",
"dc-power",
"usb-pd",
"usb-3.0",
"usb-3.1",
"audio-analog",
"serial-rs232",
"passthrough-coupler"
],
"type": "string",
"description": "Supported electrical, optical, or PoE protocol capability."
},
"default": [],
"maxItems": 32,
"description": "Electrical, optical, or PoE capabilities supported by this port."
},
"connector_type": {
"enum": [
"rj45",
"rj45-serial-console",
"sfp-plus",
"iec-c13",
"iec-c14",
"schuko-cee7",
"dc-5525",
"usb-c",
"usb-a",
"audio-35mm"
],
"type": "string",
"description": "Physical connector interface type."
},
"is_passthrough_coupler": {
"type": "boolean",
"description": "True if this port is a passive front-to-rear feedthrough coupler."
}
},
"description": "Explicit physical port definition with local millimeter coordinates."
},
"default": [],
"maxItems": 256,
"description": "Explicit physical ports with local face millimeter coordinates."
},
"slots": {
"type": "array",
"items": {
"type": "object",
"required": [
"slot_id",
"accepted_slot_type",
"offset_mm",
"max_dimensions_mm"
],
"properties": {
"slot_id": {
"type": "string",
"maxLength": 100,
"minLength": 1,
"description": "Unique slot identifier within the carrier."
},
"offset_mm": {
"type": "object",
"required": [
"x",
"y"
],
"properties": {
"x": {
"type": "number",
"maximum": 2000,
"minimum": -2000,
"description": "Local X offset from carrier origin in mm."
},
"y": {
"type": "number",
"maximum": 3000,
"minimum": -3000,
"description": "Local Y offset from carrier origin in mm."
},
"z": {
"type": "number",
"default": 0,
"maximum": 2000,
"minimum": -2000,
"description": "Local Z offset from carrier origin in mm."
}
},
"description": "Local 3D offset of a sub-module slot relative to its parent carrier."
},
"max_dimensions_mm": {
"type": "object",
"required": [
"width",
"height",
"depth"
],
"properties": {
"depth": {
"type": "number",
"maximum": 2000,
"description": "Maximum allowed child depth in mm.",
"exclusiveMinimum": 0
},
"width": {
"type": "number",
"maximum": 2000,
"description": "Maximum allowed child width in mm.",
"exclusiveMinimum": 0
},
"height": {
"type": "number",
"maximum": 3000,
"description": "Maximum allowed child height in mm.",
"exclusiveMinimum": 0
}
},
"description": "Maximum internal bounding dimensions of a carrier slot in mm."
},
"accepted_slot_type": {
"type": "string",
"maxLength": 100,
"minLength": 1,
"description": "Required child slot_compatibility token (e.g. \"mini-pc-1liter\")."
}
},
"description": "Sub-U carrier bay specification for modular child devices."
},
"default": [],
"maxItems": 32,
"description": "Sub-module carrier bays when mount_type is \"modular-carrier\"."
},
"visuals": {
"type": "object",
"default": {
"stl_mesh_path": null,
"material_preset": "matte-black-steel",
"has_oled_display": false,
"chassis_color_hex": "#E5E7EB"
},
"properties": {
"stl_mesh_path": {
"anyOf": [
{
"type": "string",
"maxLength": 512
},
{
"type": "null"
}
],
"default": null,
"description": "Optional relative path to custom 3D mesh (.stl/.glb)."
},
"material_preset": {
"enum": [
"matte-black-steel",
"coated-aluminum",
"3d-printed-petg",
"3d-printed-abs",
"polycarbonate"
],
"type": "string",
"default": "matte-black-steel",
"description": "Surface material shader preset for 3D procedural rendering."
},
"has_oled_display": {
"type": "boolean",
"default": false,
"description": "True if the front panel includes a status OLED screen."
},
"chassis_color_hex": {
"type": "string",
"default": "#E5E7EB",
"pattern": "^#[0-9A-Fa-f]{6}$",
"description": "Primary chassis hex color code."
}
},
"description": "Visual rendering metadata for 2D SVG and 3D WebGL pipelines."
},
"category": {
"enum": [
"switch",
"router",
"compute-node",
"mini-pc",
"sbc",
"nas",
"patch-panel",
"pdu",
"ups",
"modular-carrier",
"brush-panel",
"blanking-panel",
"blank-panel",
"shelf",
"keystone-module"
],
"type": "string",
"description": "Primary functional category of the hardware unit."
},
"geometry": {
"type": "object",
"required": [
"u_height",
"width_mm",
"height_mm",
"depth_mm"
],
"properties": {
"depth_mm": {
"type": "number",
"maximum": 2000,
"description": "Physical chassis depth in millimeters along the Z-axis (max 2000mm).",
"exclusiveMinimum": 0
},
"u_height": {
"type": "number",
"maximum": 60,
"minimum": 0,
"description": "Nominal height in Rack Units (1U = 44.45mm, max 60U)."
},
"width_mm": {
"type": "number",
"maximum": 1000,
"description": "Physical chassis body width in millimeters (max 1000mm).",
"exclusiveMinimum": 0
},
"height_mm": {
"type": "number",
"maximum": 3000,
"description": "Physical chassis height in millimeters (max 3000mm).",
"exclusiveMinimum": 0
},
"weight_grams": {
"type": "number",
"default": 0,
"maximum": 500000,
"minimum": 0,
"description": "Total device mass in grams for Center of Gravity calculation."
},
"ear_mount_style": {
"enum": [
"included-19inch-ears",
"included-10inch-ears",
"included-6inch-ears",
"flush-front",
"recessed-20mm",
"sub-module-clip",
"rear-rail-mount",
"none"
],
"type": "string",
"default": "flush-front",
"description": "Mounting ear geometry relative to the vertical rack rails."
},
"rear_protrusion_mm": {
"type": "number",
"default": 0,
"maximum": 500,
"minimum": 0,
"description": "Protrusion behind depth_mm (fans, PSU handles) in mm."
},
"front_protrusion_mm": {
"type": "number",
"default": 0,
"maximum": 500,
"minimum": 0,
"description": "Protrusion in front of Z=0 (handles, ears, knobs) in mm."
},
"has_cable_pass_through": {
"type": "boolean",
"description": "True if cables can pass front-to-rear through this unit."
}
},
"description": "Physical 3D bounding dimensions and mass specification."
},
"mount_type": {
"enum": [
"rackmount-19",
"rackmount-10",
"rackmount-6",
"sub-module",
"shelf-standing"
],
"type": "string",
"description": "Physical form factor and mounting mechanism."
},
"description": {
"type": "string",
"maxLength": 2000,
"description": "Human-readable explanation of what the device is, its role in the rack, and its physical mounting method (e.g. native rack ears vs. 3D-printed carrier/cradle)."
},
"port_groups": {
"type": "array",
"items": {
"type": "object",
"required": [
"id_prefix",
"count",
"face",
"connector_type",
"direction",
"grid"
],
"properties": {
"face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"grid": {
"type": "object",
"required": [
"origin_x_mm",
"origin_y_mm",
"columns",
"rows",
"pitch_x_mm",
"pitch_y_mm"
],
"properties": {
"rows": {
"type": "integer",
"maximum": 16,
"description": "Number of vertical port rows in the matrix (1..16).",
"exclusiveMinimum": 0
},
"columns": {
"type": "integer",
"maximum": 64,
"description": "Number of horizontal port columns in the matrix (1..64).",
"exclusiveMinimum": 0
},
"pitch_x_mm": {
"type": "number",
"maximum": 500,
"minimum": -500,
"description": "Horizontal center-to-center spacing between adjacent columns in mm."
},
"pitch_y_mm": {
"type": "number",
"maximum": 500,
"minimum": -500,
"description": "Vertical center-to-center spacing between adjacent rows in mm."
},
"origin_x_mm": {
"type": "number",
"maximum": 2000,
"minimum": -2000,
"description": "X coordinate of the first port (column 0) in mm."
},
"origin_y_mm": {
"type": "number",
"maximum": 3000,
"minimum": -3000,
"description": "Y coordinate of the first port (row 0) in mm."
}
},
"description": "2D grid layout parameters for automatic port matrix expansion."
},
"count": {
"type": "integer",
"maximum": 128,
"description": "Total number of ports to generate in this group (1..128).",
"exclusiveMinimum": 0
},
"direction": {
"enum": [
"input",
"output",
"bidirectional"
],
"type": "string",
"description": "Signal or electrical power flow direction."
},
"id_prefix": {
"type": "string",
"maxLength": 64,
"minLength": 1,
"description": "Prefix for generated port_id values (e.g. \"eth\")."
},
"orientation": {
"enum": [
"upright",
"inverted",
"left",
"right"
],
"type": "string",
"default": "upright",
"description": "Physical orientation of the connector latch/keyway."
},
"start_index": {
"type": "integer",
"default": 1,
"maximum": 10000,
"minimum": 0,
"description": "Starting numeric suffix for generated port IDs (default: 1)."
},
"capabilities": {
"type": "array",
"items": {
"enum": [
"100base-tx",
"1000base-t",
"2500base-t",
"5gbase-t",
"10gbase-t",
"10gbase-sr",
"10gbase-lr",
"10gbase-dac",
"25gbase-dac",
"poe-out",
"poe+",
"poe-out-af",
"poe-out-at",
"poe-out-bt-type3",
"poe-out-bt-type4",
"poe-in-af",
"poe-in-at",
"poe-in-bt-type3",
"poe-in-bt-type4",
"ac-mains",
"dc-power",
"usb-pd",
"usb-3.0",
"usb-3.1",
"audio-analog",
"serial-rs232",
"passthrough-coupler"
],
"type": "string",
"description": "Supported electrical, optical, or PoE protocol capability."
},
"default": [],
"maxItems": 32,
"description": "Capabilities assigned to every port generated by this group."
},
"label_prefix": {
"type": "string",
"maxLength": 96,
"description": "Prefix for generated human-readable labels."
},
"connector_type": {
"enum": [
"rj45",
"rj45-serial-console",
"sfp-plus",
"iec-c13",
"iec-c14",
"schuko-cee7",
"dc-5525",
"usb-c",
"usb-a",
"audio-35mm"
],
"type": "string",
"description": "Physical connector interface type."
},
"is_passthrough_coupler": {
"type": "boolean",
"description": "True if generated ports are passive front-to-rear couplers."
}
},
"description": "Declarative port matrix macro expanded into flat PortDefinition items on load."
},
"default": [],
"maxItems": 16,
"description": "Optional repeating port grid macros expanded into flat ports[] upon registration."
},
"manufacturer": {
"type": "string",
"maxLength": 160,
"minLength": 1,
"description": "Hardware manufacturer name."
},
"power_and_thermal": {
"type": "object",
"required": [
"electrical_role"
],
"properties": {
"airflow": {
"enum": [
"front-to-rear",
"rear-to-front",
"side-to-side",
"passive-convection",
"none"
],
"type": "string",
"default": "passive-convection",
"description": "Primary thermal airflow path through the device chassis."
},
"idle_watts": {
"type": "number",
"default": 0,
"maximum": 100000,
"minimum": 0,
"description": "Idle power draw in watts."
},
"noise_db_a": {
"type": "number",
"maximum": 200,
"minimum": 0,
"description": "Acoustic noise emission in dB(A) at 1 meter distance."
},
"electrical_role": {
"enum": [
"consumer",
"pse-switch",
"pdu",
"ups",
"passive"
],
"type": "string",
"description": "Role in the electrical and PoE Directed Acyclic Graph (DAG)."
},
"max_system_watts": {
"type": "number",
"default": 0,
"maximum": 100000,
"minimum": 0,
"description": "Peak own system power consumption in watts (excluding PoE output)."
},
"poe_budget_watts": {
"type": "number",
"maximum": 100000,
"minimum": 0,
"description": "Maximum total PoE output power budget in watts for PSE switches."
},
"pdu_capacity_watts": {
"type": "number",
"maximum": 100000,
"description": "Maximum output load capacity in watts for PDU units.",
"exclusiveMinimum": 0
},
"ups_capacity_watts": {
"type": "number",
"maximum": 100000,
"description": "Maximum output load capacity in watts for UPS units.",
"exclusiveMinimum": 0
}
},
"description": "Electrical power consumption, PoE budget, thermal airflow, and acoustic dB(A) characteristics."
},
"printable_metadata": {
"anyOf": [
{
"type": "object",
"required": [
"filament_grams"
],
"properties": {
"fasteners": {
"type": "string",
"maxLength": 256,
"description": "Optional specification of required mounting screws and cage nuts."
},
"filament_grams": {
"type": "number",
"maximum": 50000,
"minimum": 0,
"description": "Estimated filament mass in grams."
},
"printables_url": {
"type": "string",
"pattern": "^https?:\\/\\/",
"maxLength": 512,
"description": "Optional HTTPS reference URL to an upstream 3D model repository."
},
"heat_set_inserts": {
"type": "string",
"maxLength": 256,
"description": "Optional specification of required brass heat-set inserts."
},
"material_recommendation": {
"type": "string",
"default": "PETG",
"maxLength": 128,
"description": "Recommended 3D printing filament material (e.g. \"PETG\", \"ABS\", \"ASA\")."
}
}
},
{
"type": "null"
}
],
"default": null,
"description": "3D printing fabrication metadata for printable modular carriers."
},
"slot_compatibility": {
"type": "string",
"maxLength": 100,
"description": "Slot compatibility token when mount_type is \"sub-module\"."
},
"is_passthrough_coupler": {
"type": "boolean",
"description": "True if the entire unit acts as a passive front-to-rear feedthrough patch panel."
}
},
"description": "Complete custom hardware blueprint specification; ports may be defined via explicit ports[], repeating port_groups[] macros, or both."
}
}
},
"outputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"status",
"summary",
"data",
"issues"
],
"properties": {
"data": {
"type": "object",
"properties": {
"slug": {
"type": "string",
"description": "Registered lowercase kebab-case blueprint slug."
},
"blueprint": {
"type": "object",
"required": [
"slug",
"manufacturer",
"model",
"category",
"mount_type",
"geometry",
"power_and_thermal",
"port_groups",
"ports",
"slots",
"visuals",
"printable_metadata"
],
"properties": {
"slug": {
"type": "string",
"pattern": "^[a-z0-9-]+$",
"maxLength": 100,
"minLength": 1,
"description": "Unique lowercase kebab-case hardware identifier (vendor-model-variant)."
},
"model": {
"type": "string",
"maxLength": 160,
"minLength": 1,
"description": "Hardware model name or part number."
},
"ports": {
"type": "array",
"items": {
"type": "object",
"required": [
"port_id",
"label",
"face",
"connector_type",
"direction",
"capabilities",
"coordinates"
],
"properties": {
"face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"label": {
"type": "string",
"maxLength": 160,
"minLength": 1,
"description": "Human-readable silk-screened port label."
},
"port_id": {
"type": "string",
"maxLength": 128,
"minLength": 1,
"description": "Unique identifier of the port within the device."
},
"direction": {
"enum": [
"input",
"output",
"bidirectional"
],
"type": "string",
"description": "Signal or electrical power flow direction."
},
"coordinates": {
"type": "object",
"required": [
"x_mm",
"y_mm",
"orientation"
],
"properties": {
"x_mm": {
"type": "number",
"maximum": 2000,
"minimum": -2000,
"description": "Horizontal offset in mm from the bottom-left corner of the face."
},
"y_mm": {
"type": "number",
"maximum": 3000,
"minimum": -3000,
"description": "Vertical offset in mm from the bottom-left corner of the face."
},
"orientation": {
"enum": [
"upright",
"inverted",
"left",
"right"
],
"type": "string",
"default": "upright",
"description": "Physical orientation of the connector latch/keyway."
}
},
"description": "Local 2D coordinates on the device face in millimeters.",
"additionalProperties": false
},
"capabilities": {
"type": "array",
"items": {
"enum": [
"100base-tx",
"1000base-t",
"2500base-t",
"5gbase-t",
"10gbase-t",
"10gbase-sr",
"10gbase-lr",
"10gbase-dac",
"25gbase-dac",
"poe-out",
"poe+",
"poe-out-af",
"poe-out-at",
"poe-out-bt-type3",
"poe-out-bt-type4",
"poe-in-af",
"poe-in-at",
"poe-in-bt-type3",
"poe-in-bt-type4",
"ac-mains",
"dc-power",
"usb-pd",
"usb-3.0",
"usb-3.1",
"audio-analog",
"serial-rs232",
"passthrough-coupler"
],
"type": "string",
"description": "Supported electrical, optical, or PoE protocol capability."
},
"default": [],
"maxItems": 32,
"description": "Electrical, optical, or PoE capabilities supported by this port."
},
"connector_type": {
"enum": [
"rj45",
"rj45-serial-console",
"sfp-plus",
"iec-c13",
"iec-c14",
"schuko-cee7",
"dc-5525",
"usb-c",
"usb-a",
"audio-35mm"
],
"type": "string",
"description": "Physical connector interface type."
},
"is_passthrough_coupler": {
"type": "boolean",
"description": "True if this port is a passive front-to-rear feedthrough coupler."
}
},
"description": "Explicit physical port definition with local millimeter coordinates.",
"additionalProperties": false
},
"default": [],
"maxItems": 256,
"description": "Explicit physical ports with local face millimeter coordinates."
},
"slots": {
"type": "array",
"items": {
"type": "object",
"required": [
"slot_id",
"accepted_slot_type",
"offset_mm",
"max_dimensions_mm"
],
"properties": {
"slot_id": {
"type": "string",
"maxLength": 100,
"minLength": 1,
"description": "Unique slot identifier within the carrier."
},
"offset_mm": {
"type": "object",
"required": [
"x",
"y",
"z"
],
"properties": {
"x": {
"type": "number",
"maximum": 2000,
"minimum": -2000,
"description": "Local X offset from carrier origin in mm."
},
"y": {
"type": "number",
"maximum": 3000,
"minimum": -3000,
"description": "Local Y offset from carrier origin in mm."
},
"z": {
"type": "number",
"default": 0,
"maximum": 2000,
"minimum": -2000,
"description": "Local Z offset from carrier origin in mm."
}
},
"description": "Local 3D offset of a sub-module slot relative to its parent carrier.",
"additionalProperties": false
},
"max_dimensions_mm": {
"type": "object",
"required": [
"width",
"height",
"depth"
],
"properties": {
"depth": {
"type": "number",
"maximum": 2000,
"description": "Maximum allowed child depth in mm.",
"exclusiveMinimum": 0
},
"width": {
"type": "number",
"maximum": 2000,
"description": "Maximum allowed child width in mm.",
"exclusiveMinimum": 0
},
"height": {
"type": "number",
"maximum": 3000,
"description": "Maximum allowed child height in mm.",
"exclusiveMinimum": 0
}
},
"description": "Maximum internal bounding dimensions of a carrier slot in mm.",
"additionalProperties": false
},
"accepted_slot_type": {
"type": "string",
"maxLength": 100,
"minLength": 1,
"description": "Required child slot_compatibility token (e.g. \"mini-pc-1liter\")."
}
},
"description": "Sub-U carrier bay specification for modular child devices.",
"additionalProperties": false
},
"default": [],
"maxItems": 32,
"description": "Sub-module carrier bays when mount_type is \"modular-carrier\"."
},
"visuals": {
"type": "object",
"default": {
"stl_mesh_path": null,
"material_preset": "matte-black-steel",
"has_oled_display": false,
"chassis_color_hex": "#E5E7EB"
},
"required": [
"chassis_color_hex",
"material_preset",
"has_oled_display",
"stl_mesh_path"
],
"properties": {
"stl_mesh_path": {
"anyOf": [
{
"type": "string",
"maxLength": 512
},
{
"type": "null"
}
],
"default": null,
"description": "Optional relative path to custom 3D mesh (.stl/.glb)."
},
"material_preset": {
"enum": [
"matte-black-steel",
"coated-aluminum",
"3d-printed-petg",
"3d-printed-abs",
"polycarbonate"
],
"type": "string",
"default": "matte-black-steel",
"description": "Surface material shader preset for 3D procedural rendering."
},
"has_oled_display": {
"type": "boolean",
"default": false,
"description": "True if the front panel includes a status OLED screen."
},
"chassis_color_hex": {
"type": "string",
"default": "#E5E7EB",
"pattern": "^#[0-9A-Fa-f]{6}$",
"description": "Primary chassis hex color code."
}
},
"description": "Visual rendering metadata for 2D SVG and 3D WebGL pipelines.",
"additionalProperties": false
},
"category": {
"enum": [
"switch",
"router",
"compute-node",
"mini-pc",
"sbc",
"nas",
"patch-panel",
"pdu",
"ups",
"modular-carrier",
"brush-panel",
"blanking-panel",
"blank-panel",
"shelf",
"keystone-module"
],
"type": "string",
"description": "Primary functional category of the hardware unit."
},
"geometry": {
"type": "object",
"required": [
"u_height",
"width_mm",
"height_mm",
"depth_mm",
"ear_mount_style",
"front_protrusion_mm",
"rear_protrusion_mm",
"weight_grams"
],
"properties": {
"depth_mm": {
"type": "number",
"maximum": 2000,
"description": "Physical chassis depth in millimeters along the Z-axis (max 2000mm).",
"exclusiveMinimum": 0
},
"u_height": {
"type": "number",
"maximum": 60,
"minimum": 0,
"description": "Nominal height in Rack Units (1U = 44.45mm, max 60U)."
},
"width_mm": {
"type": "number",
"maximum": 1000,
"description": "Physical chassis body width in millimeters (max 1000mm).",
"exclusiveMinimum": 0
},
"height_mm": {
"type": "number",
"maximum": 3000,
"description": "Physical chassis height in millimeters (max 3000mm).",
"exclusiveMinimum": 0
},
"weight_grams": {
"type": "number",
"default": 0,
"maximum": 500000,
"minimum": 0,
"description": "Total device mass in grams for Center of Gravity calculation."
},
"ear_mount_style": {
"enum": [
"included-19inch-ears",
"included-10inch-ears",
"included-6inch-ears",
"flush-front",
"recessed-20mm",
"sub-module-clip",
"rear-rail-mount",
"none"
],
"type": "string",
"default": "flush-front",
"description": "Mounting ear geometry relative to the vertical rack rails."
},
"rear_protrusion_mm": {
"type": "number",
"default": 0,
"maximum": 500,
"minimum": 0,
"description": "Protrusion behind depth_mm (fans, PSU handles) in mm."
},
"front_protrusion_mm": {
"type": "number",
"default": 0,
"maximum": 500,
"minimum": 0,
"description": "Protrusion in front of Z=0 (handles, ears, knobs) in mm."
},
"has_cable_pass_through": {
"type": "boolean",
"description": "True if cables can pass front-to-rear through this unit."
}
},
"description": "Physical 3D bounding dimensions and mass specification.",
"additionalProperties": false
},
"mount_type": {
"enum": [
"rackmount-19",
"rackmount-10",
"rackmount-6",
"sub-module",
"shelf-standing"
],
"type": "string",
"description": "Physical form factor and mounting mechanism."
},
"description": {
"type": "string",
"maxLength": 2000,
"description": "Human-readable explanation of what the device is, its role in the rack, and its physical mounting method (e.g. native rack ears vs. 3D-printed carrier/cradle)."
},
"port_groups": {
"type": "array",
"items": {
"type": "object",
"required": [
"id_prefix",
"start_index",
"count",
"face",
"connector_type",
"direction",
"capabilities",
"orientation",
"grid"
],
"properties": {
"face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"grid": {
"type": "object",
"required": [
"origin_x_mm",
"origin_y_mm",
"columns",
"rows",
"pitch_x_mm",
"pitch_y_mm"
],
"properties": {
"rows": {
"type": "integer",
"maximum": 16,
"description": "Number of vertical port rows in the matrix (1..16).",
"exclusiveMinimum": 0
},
"columns": {
"type": "integer",
"maximum": 64,
"description": "Number of horizontal port columns in the matrix (1..64).",
"exclusiveMinimum": 0
},
"pitch_x_mm": {
"type": "number",
"maximum": 500,
"minimum": -500,
"description": "Horizontal center-to-center spacing between adjacent columns in mm."
},
"pitch_y_mm": {
"type": "number",
"maximum": 500,
"minimum": -500,
"description": "Vertical center-to-center spacing between adjacent rows in mm."
},
"origin_x_mm": {
"type": "number",
"maximum": 2000,
"minimum": -2000,
"description": "X coordinate of the first port (column 0) in mm."
},
"origin_y_mm": {
"type": "number",
"maximum": 3000,
"minimum": -3000,
"description": "Y coordinate of the first port (row 0) in mm."
}
},
"description": "2D grid layout parameters for automatic port matrix expansion.",
"additionalProperties": false
},
"count": {
"type": "integer",
"maximum": 128,
"description": "Total number of ports to generate in this group (1..128).",
"exclusiveMinimum": 0
},
"direction": {
"enum": [
"input",
"output",
"bidirectional"
],
"type": "string",
"description": "Signal or electrical power flow direction."
},
"id_prefix": {
"type": "string",
"maxLength": 64,
"minLength": 1,
"description": "Prefix for generated port_id values (e.g. \"eth\")."
},
"orientation": {
"enum": [
"upright",
"inverted",
"left",
"right"
],
"type": "string",
"default": "upright",
"description": "Physical orientation of the connector latch/keyway."
},
"start_index": {
"type": "integer",
"default": 1,
"maximum": 10000,
"minimum": 0,
"description": "Starting numeric suffix for generated port IDs (default: 1)."
},
"capabilities": {
"type": "array",
"items": {
"enum": [
"100base-tx",
"1000base-t",
"2500base-t",
"5gbase-t",
"10gbase-t",
"10gbase-sr",
"10gbase-lr",
"10gbase-dac",
"25gbase-dac",
"poe-out",
"poe+",
"poe-out-af",
"poe-out-at",
"poe-out-bt-type3",
"poe-out-bt-type4",
"poe-in-af",
"poe-in-at",
"poe-in-bt-type3",
"poe-in-bt-type4",
"ac-mains",
"dc-power",
"usb-pd",
"usb-3.0",
"usb-3.1",
"audio-analog",
"serial-rs232",
"passthrough-coupler"
],
"type": "string",
"description": "Supported electrical, optical, or PoE protocol capability."
},
"default": [],
"maxItems": 32,
"description": "Capabilities assigned to every port generated by this group."
},
"label_prefix": {
"type": "string",
"maxLength": 96,
"description": "Prefix for generated human-readable labels."
},
"connector_type": {
"enum": [
"rj45",
"rj45-serial-console",
"sfp-plus",
"iec-c13",
"iec-c14",
"schuko-cee7",
"dc-5525",
"usb-c",
"usb-a",
"audio-35mm"
],
"type": "string",
"description": "Physical connector interface type."
},
"is_passthrough_coupler": {
"type": "boolean",
"description": "True if generated ports are passive front-to-rear couplers."
}
},
"description": "Declarative port matrix macro expanded into flat PortDefinition items on load.",
"additionalProperties": false
},
"default": [],
"maxItems": 16,
"description": "Optional repeating port grid macros expanded into flat ports[] upon registration."
},
"manufacturer": {
"type": "string",
"maxLength": 160,
"minLength": 1,
"description": "Hardware manufacturer name."
},
"power_and_thermal": {
"type": "object",
"required": [
"electrical_role",
"idle_watts",
"max_system_watts",
"airflow"
],
"properties": {
"airflow": {
"enum": [
"front-to-rear",
"rear-to-front",
"side-to-side",
"passive-convection",
"none"
],
"type": "string",
"default": "passive-convection",
"description": "Primary thermal airflow path through the device chassis."
},
"idle_watts": {
"type": "number",
"default": 0,
"maximum": 100000,
"minimum": 0,
"description": "Idle power draw in watts."
},
"noise_db_a": {
"type": "number",
"maximum": 200,
"minimum": 0,
"description": "Acoustic noise emission in dB(A) at 1 meter distance."
},
"electrical_role": {
"enum": [
"consumer",
"pse-switch",
"pdu",
"ups",
"passive"
],
"type": "string",
"description": "Role in the electrical and PoE Directed Acyclic Graph (DAG)."
},
"max_system_watts": {
"type": "number",
"default": 0,
"maximum": 100000,
"minimum": 0,
"description": "Peak own system power consumption in watts (excluding PoE output)."
},
"poe_budget_watts": {
"type": "number",
"maximum": 100000,
"minimum": 0,
"description": "Maximum total PoE output power budget in watts for PSE switches."
},
"pdu_capacity_watts": {
"type": "number",
"maximum": 100000,
"description": "Maximum output load capacity in watts for PDU units.",
"exclusiveMinimum": 0
},
"ups_capacity_watts": {
"type": "number",
"maximum": 100000,
"description": "Maximum output load capacity in watts for UPS units.",
"exclusiveMinimum": 0
}
},
"description": "Electrical power consumption, PoE budget, thermal airflow, and acoustic dB(A) characteristics.",
"additionalProperties": false
},
"printable_metadata": {
"anyOf": [
{
"type": "object",
"required": [
"filament_grams",
"material_recommendation"
],
"properties": {
"fasteners": {
"type": "string",
"maxLength": 256,
"description": "Optional specification of required mounting screws and cage nuts."
},
"filament_grams": {
"type": "number",
"maximum": 50000,
"minimum": 0,
"description": "Estimated filament mass in grams."
},
"printables_url": {
"type": "string",
"pattern": "^https?:\\/\\/",
"maxLength": 512,
"description": "Optional HTTPS reference URL to an upstream 3D model repository."
},
"heat_set_inserts": {
"type": "string",
"maxLength": 256,
"description": "Optional specification of required brass heat-set inserts."
},
"material_recommendation": {
"type": "string",
"default": "PETG",
"maxLength": 128,
"description": "Recommended 3D printing filament material (e.g. \"PETG\", \"ABS\", \"ASA\")."
}
},
"additionalProperties": false
},
{
"type": "null"
}
],
"default": null,
"description": "3D printing fabrication metadata for printable modular carriers."
},
"slot_compatibility": {
"type": "string",
"maxLength": 100,
"description": "Slot compatibility token when mount_type is \"sub-module\"."
},
"is_passthrough_coupler": {
"type": "boolean",
"description": "True if the entire unit acts as a passive front-to-rear feedthrough patch panel."
}
},
"description": "Registered hardware blueprint with expanded port coordinates.",
"additionalProperties": false
},
"saved_path": {
"type": [
"string",
"null"
],
"description": "Absolute filesystem path of the persisted custom blueprint YAML file, or null if in-memory."
},
"validation_errors": {
"type": "array",
"items": {},
"description": "Schema validation details if the custom blueprint failed parsing."
}
},
"description": "Custom blueprint registration payload.",
"additionalProperties": {}
},
"issues": {
"type": "array",
"items": {
"type": "object",
"required": [
"code",
"severity",
"affected_instances",
"message",
"remediation_suggestions"
],
"properties": {
"code": {
"enum": [
"CHASSIS_COLLISION",
"PLUG_CLEARANCE_COLLISION",
"FRONT_DOOR_COLLISION",
"SLOT_DIMENSION_OVERFLOW",
"SLOT_INCOMPATIBLE",
"OUT_OF_RACK_BOUNDS",
"BLUEPRINT_NOT_FOUND",
"PORT_NOT_FOUND",
"PORT_ALREADY_OCCUPIED",
"CONNECTOR_INCOMPATIBLE",
"SIGNAL_PROTOCOL_INCOMPATIBLE",
"SPEED_MISMATCH",
"POE_BUDGET_EXCEEDED",
"POE_CLASS_EXCEEDED",
"UPS_OVERLOAD",
"UNPOWERED_DEVICE",
"TOP_HEAVY_RACK",
"NO_FRONT_TO_REAR_PORTAL",
"THERMAL_AIRFLOW_CONFLICT",
"THERMAL_HOTSPOT_STACKING",
"ACOUSTIC_NOISE_HIGH"
],
"type": "string",
"description": "Machine-readable deterministic validation diagnostic code."
},
"stage": {
"type": "integer",
"maximum": 5,
"minimum": 1,
"description": "Validation pipeline stage (1..5) that produced this finding."
},
"message": {
"type": "string",
"description": "Detailed engineering explanation with exact millimeter/watt figures."
},
"u_range": {
"type": "array",
"items": [
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
}
],
"maxItems": 2,
"minItems": 2,
"description": "Inclusive [start_u, end_u] range where the issue occurs.",
"additionalItems": false
},
"severity": {
"enum": [
"ERROR",
"WARNING",
"INFO"
],
"type": "string",
"description": "Severity level of the engineering constraint diagnostic."
},
"affected_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Device instance IDs involved in this diagnostic issue."
},
"remediation_actions": {
"type": "array",
"items": {
"type": "object",
"required": [
"action_type",
"description"
],
"properties": {
"action_type": {
"enum": [
"move_device",
"change_cable_type",
"connect_power",
"disconnect_cable",
"redistribute_poe",
"add_portal_gap",
"change_rack_depth"
],
"type": "string",
"description": "Recommended self-correction operation category."
},
"description": {
"type": "string",
"description": "Human- and agent-readable explanation of the remediation step."
},
"suggested_face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"target_cable_id": {
"type": "string",
"description": "Cable connection cable_id targeted by this remediation action."
},
"target_instance_id": {
"type": "string",
"description": "Device instance_id targeted by this remediation action."
},
"suggested_cable_type": {
"type": "string",
"description": "Suggested replacement cable_type (e.g. angled plug or higher speed grade)."
},
"suggested_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"exclusiveMinimum": 0
},
"description": "Candidate 1-indexed U positions that resolve the spatial conflict."
}
},
"description": "Structured self-correction action for autonomous agent remediation.",
"additionalProperties": false
},
"description": "Optional machine-actionable remediation descriptors."
},
"remediation_suggestions": {
"type": "array",
"items": {
"type": "string"
},
"minItems": 1,
"description": "Actionable self-correction instructions for the calling LLM agent."
}
},
"description": "Single validation finding with deterministic self-correction feedback.",
"additionalProperties": false
},
"description": "Structured diagnostic findings (ERROR, WARNING, INFO) with actionable remediation_suggestions."
},
"status": {
"enum": [
"VALID",
"INVALID"
],
"type": "string",
"description": "Deterministic execution outcome: \"VALID\" when the operation succeeded with 0 validation errors; \"INVALID\" when precondition or engineering validation errors are present in issues[]."
},
"summary": {
"type": "string",
"description": "Concise human- and agent-readable summary of the tool result and validation status."
}
},
"additionalProperties": false
},
"annotations": {
"title": "Register Custom Hardware Blueprint",
"readOnlyHint": false,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Initialize a new rack project and destructively reset the active rack.yaml state to an empty enclosure with the specified width standard, U height, and rail depth. Overwrites the current enclosure and clears all mounted devices, child sub-modules, cables, and external endpoints, while pushing the previous project state onto the in-memory undo stack for recovery via undo_redo. 'project_name' sets the title used in exported schematics and BOMs, 'rail_depth_mm' plus 'rear_clearance_mm' bounds total +Z chassis and rear plug depth before wall collision, and 'front_door_clearance_mm' is enforced only when 'enclosure_type' has a closed front door. Use when starting a rack design from scratch or changing enclosure dimensions; use validate_rack to inspect the current rack, or modify_equipment to move or remove individual devices.
| Parameter | Type | Description |
|---|---|---|
| standard * | string | Mechanical rack width standard ("19inch" = 482.6mm, "10inch" = 254.0mm, "6inch" = 152.4mm). |
| u_height * | integer | Total usable vertical rack height in Rack Units (1U = 44.45mm, 1..60U). |
| project_name | string | Human-readable project name stored in rack.yaml. |
| rail_depth_mm * | number | Front-to-rear mounting rail depth in millimeters along the Z-axis (max 2000mm). |
| enclosure_type | string | Enclosure door style ("open-frame", "closed-glass-front", or "closed-vented-front"). |
| rear_clearance_mm | number | Available clearance in millimeters behind the rear mounting rails (Z=rail_depth_mm) for power plugs and bending radii. |
| front_door_clearance_mm | number | Available clearance in millimeters between front mounting rails (Z=0) and a closed front door. |
{
"name": "init_rack",
"title": "Initialize and Reset Rack Enclosure",
"description": "Initialize a new rack project and destructively reset the active rack.yaml state to an empty enclosure with the specified width standard, U height, and rail depth. Overwrites the current enclosure and clears all mounted devices, child sub-modules, cables, and external endpoints, while pushing the previous project state onto the in-memory undo stack for recovery via undo_redo. 'project_name' sets the title used in exported schematics and BOMs, 'rail_depth_mm' plus 'rear_clearance_mm' bounds total +Z chassis and rear plug depth before wall collision, and 'front_door_clearance_mm' is enforced only when 'enclosure_type' has a closed front door. Use when starting a rack design from scratch or changing enclosure dimensions; use validate_rack to inspect the current rack, or modify_equipment to move or remove individual devices.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"standard",
"u_height",
"rail_depth_mm"
],
"properties": {
"standard": {
"enum": [
"19inch",
"10inch",
"6inch"
],
"type": "string",
"description": "Mechanical rack width standard (\"19inch\" = 482.6mm, \"10inch\" = 254.0mm, \"6inch\" = 152.4mm)."
},
"u_height": {
"type": "integer",
"maximum": 60,
"description": "Total usable vertical rack height in Rack Units (1U = 44.45mm, 1..60U).",
"exclusiveMinimum": 0
},
"project_name": {
"type": "string",
"default": "Rack Project",
"maxLength": 160,
"minLength": 1,
"description": "Human-readable project name stored in rack.yaml."
},
"rail_depth_mm": {
"type": "number",
"maximum": 2000,
"description": "Front-to-rear mounting rail depth in millimeters along the Z-axis (max 2000mm).",
"exclusiveMinimum": 0
},
"enclosure_type": {
"enum": [
"open-frame",
"closed-glass-front",
"closed-vented-front"
],
"type": "string",
"default": "open-frame",
"description": "Enclosure door style (\"open-frame\", \"closed-glass-front\", or \"closed-vented-front\")."
},
"rear_clearance_mm": {
"type": "number",
"default": 40,
"maximum": 1000,
"minimum": 0,
"description": "Available clearance in millimeters behind the rear mounting rails (Z=rail_depth_mm) for power plugs and bending radii."
},
"front_door_clearance_mm": {
"type": "number",
"default": 45,
"maximum": 1000,
"minimum": 0,
"description": "Available clearance in millimeters between front mounting rails (Z=0) and a closed front door."
}
}
},
"outputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"status",
"summary",
"data",
"issues"
],
"properties": {
"data": {
"type": "object",
"required": [
"rack",
"geometry",
"validation"
],
"properties": {
"rack": {
"type": "object",
"required": [
"standard",
"u_height",
"rail_depth_mm",
"enclosure_type",
"front_door_clearance_mm",
"rear_clearance_mm"
],
"properties": {
"standard": {
"enum": [
"19inch",
"10inch",
"6inch"
],
"type": "string",
"description": "EIA-310-D or homelab rack width standard."
},
"u_height": {
"type": "integer",
"maximum": 60,
"description": "Total vertical rack capacity in Rack Units (U / HE, 1..60).",
"exclusiveMinimum": 0
},
"rail_depth_mm": {
"type": "number",
"maximum": 2000,
"description": "Distance from front mounting rail face (Z=0) to rear mounting rail face in mm (max 2000mm).",
"exclusiveMinimum": 0
},
"enclosure_type": {
"enum": [
"open-frame",
"closed-glass-front",
"closed-vented-front"
],
"type": "string",
"default": "open-frame",
"description": "Physical rack enclosure style governing front door clearance checks."
},
"rear_clearance_mm": {
"type": "number",
"default": 40,
"maximum": 1000,
"minimum": 0,
"description": "Available clearance behind Z=rail_depth_mm in mm."
},
"front_door_clearance_mm": {
"type": "number",
"default": 45,
"maximum": 1000,
"minimum": 0,
"description": "Available clearance in front of Z=0 before hitting the front door in mm."
}
},
"description": "Initialized physical rack frame specification.",
"additionalProperties": false
},
"geometry": {
"type": "object",
"required": [
"total_height_mm",
"rail_depth_mm",
"panel_width_mm",
"aperture_width_mm"
],
"properties": {
"rail_depth_mm": {
"type": "number",
"description": "Front-to-rear mounting rail depth in millimeters."
},
"panel_width_mm": {
"type": "number",
"description": "Outer mounting ear panel width in millimeters."
},
"total_height_mm": {
"type": "number",
"description": "Total vertical mounting height in millimeters (u_height * 44.45)."
},
"aperture_width_mm": {
"type": "number",
"description": "Inner usable rail aperture width in millimeters."
}
},
"description": "Computed millimeter enclosure dimensions.",
"additionalProperties": {}
},
"validation": {
"type": "object",
"required": [
"status",
"is_valid",
"error_count",
"warning_count",
"issues",
"power_summary",
"mechanical_summary"
],
"properties": {
"issues": {
"type": "array",
"items": {
"type": "object",
"required": [
"code",
"severity",
"affected_instances",
"message",
"remediation_suggestions"
],
"properties": {
"code": {
"enum": [
"CHASSIS_COLLISION",
"PLUG_CLEARANCE_COLLISION",
"FRONT_DOOR_COLLISION",
"SLOT_DIMENSION_OVERFLOW",
"SLOT_INCOMPATIBLE",
"OUT_OF_RACK_BOUNDS",
"BLUEPRINT_NOT_FOUND",
"PORT_NOT_FOUND",
"PORT_ALREADY_OCCUPIED",
"CONNECTOR_INCOMPATIBLE",
"SIGNAL_PROTOCOL_INCOMPATIBLE",
"SPEED_MISMATCH",
"POE_BUDGET_EXCEEDED",
"POE_CLASS_EXCEEDED",
"UPS_OVERLOAD",
"UNPOWERED_DEVICE",
"TOP_HEAVY_RACK",
"NO_FRONT_TO_REAR_PORTAL",
"THERMAL_AIRFLOW_CONFLICT",
"THERMAL_HOTSPOT_STACKING",
"ACOUSTIC_NOISE_HIGH"
],
"type": "string",
"description": "Machine-readable deterministic validation diagnostic code."
},
"stage": {
"type": "integer",
"maximum": 5,
"minimum": 1,
"description": "Validation pipeline stage (1..5) that produced this finding."
},
"message": {
"type": "string",
"description": "Detailed engineering explanation with exact millimeter/watt figures."
},
"u_range": {
"type": "array",
"items": [
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
}
],
"maxItems": 2,
"minItems": 2,
"description": "Inclusive [start_u, end_u] range where the issue occurs.",
"additionalItems": false
},
"severity": {
"enum": [
"ERROR",
"WARNING",
"INFO"
],
"type": "string",
"description": "Severity level of the engineering constraint diagnostic."
},
"affected_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Device instance IDs involved in this diagnostic issue."
},
"remediation_actions": {
"type": "array",
"items": {
"type": "object",
"required": [
"action_type",
"description"
],
"properties": {
"action_type": {
"enum": [
"move_device",
"change_cable_type",
"connect_power",
"disconnect_cable",
"redistribute_poe",
"add_portal_gap",
"change_rack_depth"
],
"type": "string",
"description": "Recommended self-correction operation category."
},
"description": {
"type": "string",
"description": "Human- and agent-readable explanation of the remediation step."
},
"suggested_face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"target_cable_id": {
"type": "string",
"description": "Cable connection cable_id targeted by this remediation action."
},
"target_instance_id": {
"type": "string",
"description": "Device instance_id targeted by this remediation action."
},
"suggested_cable_type": {
"type": "string",
"description": "Suggested replacement cable_type (e.g. angled plug or higher speed grade)."
},
"suggested_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"exclusiveMinimum": 0
},
"description": "Candidate 1-indexed U positions that resolve the spatial conflict."
}
},
"description": "Structured self-correction action for autonomous agent remediation.",
"additionalProperties": false
},
"description": "Optional machine-actionable remediation descriptors."
},
"remediation_suggestions": {
"type": "array",
"items": {
"type": "string"
},
"minItems": 1,
"description": "Actionable self-correction instructions for the calling LLM agent."
}
},
"description": "Single validation finding with deterministic self-correction feedback.",
"additionalProperties": false
},
"description": "List of all detected ERROR, WARNING, and INFO diagnostic issues."
},
"status": {
"enum": [
"VALID",
"INVALID"
],
"type": "string",
"description": "Overall rack validation state (\"VALID\" when error_count is 0)."
},
"is_valid": {
"type": "boolean",
"description": "True when zero ERROR-level diagnostic issues exist."
},
"error_count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Total number of blocking ERROR diagnostics."
},
"power_summary": {
"type": "object",
"required": [
"total_system_watts",
"total_poe_watts",
"pse_budgets",
"power_sources",
"unpowered_active_instances"
],
"properties": {
"pse_budgets": {
"type": "array",
"items": {
"type": "object",
"required": [
"pse_instance_id",
"poe_budget_watts",
"consumed_poe_watts",
"remaining_poe_watts",
"downstream_devices"
],
"properties": {
"pse_instance_id": {
"type": "string",
"description": "Instance ID of the PoE Power Sourcing Equipment (PSE) switch."
},
"poe_budget_watts": {
"type": "number",
"description": "Maximum rated PoE output power budget of the switch in watts."
},
"consumed_poe_watts": {
"type": "number",
"description": "Total PoE power drawn by connected Powered Devices (PDs) in watts."
},
"downstream_devices": {
"type": "array",
"items": {
"type": "string"
},
"description": "Instance or endpoint IDs of downstream PoE consumers powered by this switch."
},
"remaining_poe_watts": {
"type": "number",
"description": "Remaining available PoE power budget in watts (negative if overloaded)."
}
},
"description": "PoE budget utilization breakdown for a single PSE switch.",
"additionalProperties": false
},
"description": "Per-switch PoE budget utilization breakdown."
},
"power_sources": {
"type": "array",
"items": {
"type": "object",
"required": [
"source_instance_id",
"role",
"capacity_watts",
"total_load_watts",
"utilization_percent"
],
"properties": {
"role": {
"enum": [
"pdu",
"ups"
],
"type": "string",
"description": "Electrical source classification (\"pdu\" or \"ups\")."
},
"capacity_watts": {
"type": "number",
"description": "Maximum rated output capacity of the power source in watts."
},
"total_load_watts": {
"type": "number",
"description": "Cumulative downstream system and PoE load in watts."
},
"source_instance_id": {
"type": "string",
"description": "Instance ID of the upstream PDU or UPS unit."
},
"utilization_percent": {
"type": "number",
"description": "Percentage of rated watt capacity consumed (0..100+)."
}
},
"description": "Load and capacity summary for a mounted PDU or UPS unit.",
"additionalProperties": false
},
"description": "Per-PDU and per-UPS electrical load breakdown."
},
"total_poe_watts": {
"type": "number",
"description": "Total PoE power draw across all connected PoE devices and external drops in watts."
},
"total_system_watts": {
"type": "number",
"description": "Total peak system power draw across all mounted equipment in watts."
},
"unpowered_active_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Active device instance IDs missing a valid AC, DC, USB-C, or PoE power input."
}
},
"description": "Aggregated electrical and PoE DAG power analysis.",
"additionalProperties": false
},
"warning_count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Total number of non-blocking WARNING diagnostics."
},
"mechanical_summary": {
"type": "object",
"required": [
"total_weight_grams",
"center_of_gravity_y_mm",
"normalized_cog_y",
"available_portal_u_positions",
"total_thermal_btu_hr",
"combined_noise_db_a",
"airflow_profile"
],
"properties": {
"airflow_profile": {
"enum": [
"uniform-front-to-rear",
"uniform-passive",
"hybrid-active-passive",
"mixed-conflict"
],
"type": "string",
"default": "uniform-passive",
"description": "Rack-wide thermal airflow regime classification."
},
"normalized_cog_y": {
"type": "number",
"description": "Normalized vertical Center of Gravity ratio (0.0 = bottom, 1.0 = top; keep <= 0.50)."
},
"total_weight_grams": {
"type": "number",
"description": "Total mass of all mounted equipment in grams."
},
"combined_noise_db_a": {
"type": "number",
"default": 0,
"description": "Logarithmic sum of acoustic noise emissions in dB(A) across all mounted devices."
},
"total_thermal_btu_hr": {
"type": "number",
"default": 0,
"description": "Total peak thermal dissipation in BTU/hr (1W = 3.41214 BTU/hr)."
},
"center_of_gravity_y_mm": {
"type": "number",
"description": "Vertical Center of Gravity height from bottom of U1 in millimeters."
},
"available_portal_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
"description": "1-indexed U slots that allow front-to-rear cable pass-through (open U or brush panel)."
}
},
"description": "Aggregated mechanical mass, center of gravity, thermal BTU/hr, and acoustic dB(A) metrics.",
"additionalProperties": false
}
},
"description": "Initial 5-stage validation report for the newly initialized empty rack.",
"additionalProperties": false
}
},
"description": "Rack initialization payload.",
"additionalProperties": {}
},
"issues": {
"type": "array",
"items": {
"type": "object",
"required": [
"code",
"severity",
"affected_instances",
"message",
"remediation_suggestions"
],
"properties": {
"code": {
"enum": [
"CHASSIS_COLLISION",
"PLUG_CLEARANCE_COLLISION",
"FRONT_DOOR_COLLISION",
"SLOT_DIMENSION_OVERFLOW",
"SLOT_INCOMPATIBLE",
"OUT_OF_RACK_BOUNDS",
"BLUEPRINT_NOT_FOUND",
"PORT_NOT_FOUND",
"PORT_ALREADY_OCCUPIED",
"CONNECTOR_INCOMPATIBLE",
"SIGNAL_PROTOCOL_INCOMPATIBLE",
"SPEED_MISMATCH",
"POE_BUDGET_EXCEEDED",
"POE_CLASS_EXCEEDED",
"UPS_OVERLOAD",
"UNPOWERED_DEVICE",
"TOP_HEAVY_RACK",
"NO_FRONT_TO_REAR_PORTAL",
"THERMAL_AIRFLOW_CONFLICT",
"THERMAL_HOTSPOT_STACKING",
"ACOUSTIC_NOISE_HIGH"
],
"type": "string",
"description": "Machine-readable deterministic validation diagnostic code."
},
"stage": {
"type": "integer",
"maximum": 5,
"minimum": 1,
"description": "Validation pipeline stage (1..5) that produced this finding."
},
"message": {
"type": "string",
"description": "Detailed engineering explanation with exact millimeter/watt figures."
},
"u_range": {
"type": "array",
"items": [
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
}
],
"maxItems": 2,
"minItems": 2,
"description": "Inclusive [start_u, end_u] range where the issue occurs.",
"additionalItems": false
},
"severity": {
"enum": [
"ERROR",
"WARNING",
"INFO"
],
"type": "string",
"description": "Severity level of the engineering constraint diagnostic."
},
"affected_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Device instance IDs involved in this diagnostic issue."
},
"remediation_actions": {
"type": "array",
"items": {
"type": "object",
"required": [
"action_type",
"description"
],
"properties": {
"action_type": {
"enum": [
"move_device",
"change_cable_type",
"connect_power",
"disconnect_cable",
"redistribute_poe",
"add_portal_gap",
"change_rack_depth"
],
"type": "string",
"description": "Recommended self-correction operation category."
},
"description": {
"type": "string",
"description": "Human- and agent-readable explanation of the remediation step."
},
"suggested_face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"target_cable_id": {
"type": "string",
"description": "Cable connection cable_id targeted by this remediation action."
},
"target_instance_id": {
"type": "string",
"description": "Device instance_id targeted by this remediation action."
},
"suggested_cable_type": {
"type": "string",
"description": "Suggested replacement cable_type (e.g. angled plug or higher speed grade)."
},
"suggested_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"exclusiveMinimum": 0
},
"description": "Candidate 1-indexed U positions that resolve the spatial conflict."
}
},
"description": "Structured self-correction action for autonomous agent remediation.",
"additionalProperties": false
},
"description": "Optional machine-actionable remediation descriptors."
},
"remediation_suggestions": {
"type": "array",
"items": {
"type": "string"
},
"minItems": 1,
"description": "Actionable self-correction instructions for the calling LLM agent."
}
},
"description": "Single validation finding with deterministic self-correction feedback.",
"additionalProperties": false
},
"description": "Structured diagnostic findings (ERROR, WARNING, INFO) with actionable remediation_suggestions."
},
"status": {
"enum": [
"VALID",
"INVALID"
],
"type": "string",
"description": "Deterministic execution outcome: \"VALID\" when the operation succeeded with 0 validation errors; \"INVALID\" when precondition or engineering validation errors are present in issues[]."
},
"summary": {
"type": "string",
"description": "Concise human- and agent-readable summary of the tool result and validation status."
}
},
"additionalProperties": false
},
"annotations": {
"title": "Initialize and Reset Rack Enclosure",
"readOnlyHint": false,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": true
}
}Mount a new hardware device instance onto a rack unit or into a modular carrier bay in the active rack.yaml project and run 5-stage validation. 'instance_id' must be unique across both top-level devices and nested sub-modules, 'blueprint_slug' must reference an existing catalog or custom slug, and placement uses two mutually exclusive modes: 'u_position' with optional 'face' where the device's full U span fits within 1..u_height, or 'parent_carrier_id' plus a compatible 'slot_id' for sub-modules. Precondition errors such as duplicate 'instance_id', unknown 'blueprint_slug', or missing carriers return status 'INVALID' without mutating state, whereas 3D collision or PoE issues persist the mount, push an undo snapshot, and return remediation_suggestions. Use to add a new device instance; use modify_equipment to move, rename, or remove an existing instance, or plan_external_endpoints for off-rack room cable drops.
| Parameter | Type | Description |
|---|---|---|
| face | string | Target rack mounting face ("front" or "rear") for direct rackmount equipment. |
| slot_id | string | Target bay slot_id inside parent_carrier_id when mounting a sub-module (e.g., "left-bay", "keystone-1"). |
| hostname | string | Optional logical hostname or display label shown in elevations and schematics. |
| u_position | integer | 1-indexed lowest Rack Unit (U) when mounting directly onto the rack rails (mutually exclusive with parent_carrier_id/slot_id). |
| instance_id * | string | Unique project-wide instance identifier for this mounted device (e.g., "ups-u1", "sw-core-01"). |
| blueprint_slug * | string | Catalog or custom hardware blueprint slug to instantiate. |
| parent_carrier_id | string | Mounted parent modular-carrier instance_id when mounting a sub-module (requires slot_id; mutually exclusive with u_position). |
{
"name": "mount_equipment",
"title": "Mount Equipment into Rack Unit or Carrier Slot",
"description": "Mount a new hardware device instance onto a rack unit or into a modular carrier bay in the active rack.yaml project and run 5-stage validation. 'instance_id' must be unique across both top-level devices and nested sub-modules, 'blueprint_slug' must reference an existing catalog or custom slug, and placement uses two mutually exclusive modes: 'u_position' with optional 'face' where the device's full U span fits within 1..u_height, or 'parent_carrier_id' plus a compatible 'slot_id' for sub-modules. Precondition errors such as duplicate 'instance_id', unknown 'blueprint_slug', or missing carriers return status 'INVALID' without mutating state, whereas 3D collision or PoE issues persist the mount, push an undo snapshot, and return remediation_suggestions. Use to add a new device instance; use modify_equipment to move, rename, or remove an existing instance, or plan_external_endpoints for off-rack room cable drops.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"instance_id",
"blueprint_slug"
],
"properties": {
"face": {
"enum": [
"front",
"rear"
],
"type": "string",
"default": "front",
"description": "Target rack mounting face (\"front\" or \"rear\") for direct rackmount equipment."
},
"slot_id": {
"type": "string",
"maxLength": 100,
"description": "Target bay slot_id inside parent_carrier_id when mounting a sub-module (e.g., \"left-bay\", \"keystone-1\")."
},
"hostname": {
"type": "string",
"maxLength": 160,
"description": "Optional logical hostname or display label shown in elevations and schematics."
},
"u_position": {
"type": "integer",
"maximum": 60,
"description": "1-indexed lowest Rack Unit (U) when mounting directly onto the rack rails (mutually exclusive with parent_carrier_id/slot_id).",
"exclusiveMinimum": 0
},
"instance_id": {
"type": "string",
"maxLength": 100,
"minLength": 1,
"description": "Unique project-wide instance identifier for this mounted device (e.g., \"ups-u1\", \"sw-core-01\")."
},
"blueprint_slug": {
"type": "string",
"maxLength": 100,
"minLength": 1,
"description": "Catalog or custom hardware blueprint slug to instantiate."
},
"parent_carrier_id": {
"type": "string",
"maxLength": 100,
"description": "Mounted parent modular-carrier instance_id when mounting a sub-module (requires slot_id; mutually exclusive with u_position)."
}
}
},
"outputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"status",
"summary",
"data",
"issues"
],
"properties": {
"data": {
"type": "object",
"properties": {
"validation": {
"type": "object",
"required": [
"status",
"is_valid",
"error_count",
"warning_count",
"issues",
"power_summary",
"mechanical_summary"
],
"properties": {
"issues": {
"type": "array",
"items": {
"type": "object",
"required": [
"code",
"severity",
"affected_instances",
"message",
"remediation_suggestions"
],
"properties": {
"code": {
"enum": [
"CHASSIS_COLLISION",
"PLUG_CLEARANCE_COLLISION",
"FRONT_DOOR_COLLISION",
"SLOT_DIMENSION_OVERFLOW",
"SLOT_INCOMPATIBLE",
"OUT_OF_RACK_BOUNDS",
"BLUEPRINT_NOT_FOUND",
"PORT_NOT_FOUND",
"PORT_ALREADY_OCCUPIED",
"CONNECTOR_INCOMPATIBLE",
"SIGNAL_PROTOCOL_INCOMPATIBLE",
"SPEED_MISMATCH",
"POE_BUDGET_EXCEEDED",
"POE_CLASS_EXCEEDED",
"UPS_OVERLOAD",
"UNPOWERED_DEVICE",
"TOP_HEAVY_RACK",
"NO_FRONT_TO_REAR_PORTAL",
"THERMAL_AIRFLOW_CONFLICT",
"THERMAL_HOTSPOT_STACKING",
"ACOUSTIC_NOISE_HIGH"
],
"type": "string",
"description": "Machine-readable deterministic validation diagnostic code."
},
"stage": {
"type": "integer",
"maximum": 5,
"minimum": 1,
"description": "Validation pipeline stage (1..5) that produced this finding."
},
"message": {
"type": "string",
"description": "Detailed engineering explanation with exact millimeter/watt figures."
},
"u_range": {
"type": "array",
"items": [
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
}
],
"maxItems": 2,
"minItems": 2,
"description": "Inclusive [start_u, end_u] range where the issue occurs.",
"additionalItems": false
},
"severity": {
"enum": [
"ERROR",
"WARNING",
"INFO"
],
"type": "string",
"description": "Severity level of the engineering constraint diagnostic."
},
"affected_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Device instance IDs involved in this diagnostic issue."
},
"remediation_actions": {
"type": "array",
"items": {
"type": "object",
"required": [
"action_type",
"description"
],
"properties": {
"action_type": {
"enum": [
"move_device",
"change_cable_type",
"connect_power",
"disconnect_cable",
"redistribute_poe",
"add_portal_gap",
"change_rack_depth"
],
"type": "string",
"description": "Recommended self-correction operation category."
},
"description": {
"type": "string",
"description": "Human- and agent-readable explanation of the remediation step."
},
"suggested_face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"target_cable_id": {
"type": "string",
"description": "Cable connection cable_id targeted by this remediation action."
},
"target_instance_id": {
"type": "string",
"description": "Device instance_id targeted by this remediation action."
},
"suggested_cable_type": {
"type": "string",
"description": "Suggested replacement cable_type (e.g. angled plug or higher speed grade)."
},
"suggested_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"exclusiveMinimum": 0
},
"description": "Candidate 1-indexed U positions that resolve the spatial conflict."
}
},
"description": "Structured self-correction action for autonomous agent remediation.",
"additionalProperties": false
},
"description": "Optional machine-actionable remediation descriptors."
},
"remediation_suggestions": {
"type": "array",
"items": {
"type": "string"
},
"minItems": 1,
"description": "Actionable self-correction instructions for the calling LLM agent."
}
},
"description": "Single validation finding with deterministic self-correction feedback.",
"additionalProperties": false
},
"description": "List of all detected ERROR, WARNING, and INFO diagnostic issues."
},
"status": {
"enum": [
"VALID",
"INVALID"
],
"type": "string",
"description": "Overall rack validation state (\"VALID\" when error_count is 0)."
},
"is_valid": {
"type": "boolean",
"description": "True when zero ERROR-level diagnostic issues exist."
},
"error_count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Total number of blocking ERROR diagnostics."
},
"power_summary": {
"type": "object",
"required": [
"total_system_watts",
"total_poe_watts",
"pse_budgets",
"power_sources",
"unpowered_active_instances"
],
"properties": {
"pse_budgets": {
"type": "array",
"items": {
"type": "object",
"required": [
"pse_instance_id",
"poe_budget_watts",
"consumed_poe_watts",
"remaining_poe_watts",
"downstream_devices"
],
"properties": {
"pse_instance_id": {
"type": "string",
"description": "Instance ID of the PoE Power Sourcing Equipment (PSE) switch."
},
"poe_budget_watts": {
"type": "number",
"description": "Maximum rated PoE output power budget of the switch in watts."
},
"consumed_poe_watts": {
"type": "number",
"description": "Total PoE power drawn by connected Powered Devices (PDs) in watts."
},
"downstream_devices": {
"type": "array",
"items": {
"type": "string"
},
"description": "Instance or endpoint IDs of downstream PoE consumers powered by this switch."
},
"remaining_poe_watts": {
"type": "number",
"description": "Remaining available PoE power budget in watts (negative if overloaded)."
}
},
"description": "PoE budget utilization breakdown for a single PSE switch.",
"additionalProperties": false
},
"description": "Per-switch PoE budget utilization breakdown."
},
"power_sources": {
"type": "array",
"items": {
"type": "object",
"required": [
"source_instance_id",
"role",
"capacity_watts",
"total_load_watts",
"utilization_percent"
],
"properties": {
"role": {
"enum": [
"pdu",
"ups"
],
"type": "string",
"description": "Electrical source classification (\"pdu\" or \"ups\")."
},
"capacity_watts": {
"type": "number",
"description": "Maximum rated output capacity of the power source in watts."
},
"total_load_watts": {
"type": "number",
"description": "Cumulative downstream system and PoE load in watts."
},
"source_instance_id": {
"type": "string",
"description": "Instance ID of the upstream PDU or UPS unit."
},
"utilization_percent": {
"type": "number",
"description": "Percentage of rated watt capacity consumed (0..100+)."
}
},
"description": "Load and capacity summary for a mounted PDU or UPS unit.",
"additionalProperties": false
},
"description": "Per-PDU and per-UPS electrical load breakdown."
},
"total_poe_watts": {
"type": "number",
"description": "Total PoE power draw across all connected PoE devices and external drops in watts."
},
"total_system_watts": {
"type": "number",
"description": "Total peak system power draw across all mounted equipment in watts."
},
"unpowered_active_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Active device instance IDs missing a valid AC, DC, USB-C, or PoE power input."
}
},
"description": "Aggregated electrical and PoE DAG power analysis.",
"additionalProperties": false
},
"warning_count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Total number of non-blocking WARNING diagnostics."
},
"mechanical_summary": {
"type": "object",
"required": [
"total_weight_grams",
"center_of_gravity_y_mm",
"normalized_cog_y",
"available_portal_u_positions",
"total_thermal_btu_hr",
"combined_noise_db_a",
"airflow_profile"
],
"properties": {
"airflow_profile": {
"enum": [
"uniform-front-to-rear",
"uniform-passive",
"hybrid-active-passive",
"mixed-conflict"
],
"type": "string",
"default": "uniform-passive",
"description": "Rack-wide thermal airflow regime classification."
},
"normalized_cog_y": {
"type": "number",
"description": "Normalized vertical Center of Gravity ratio (0.0 = bottom, 1.0 = top; keep <= 0.50)."
},
"total_weight_grams": {
"type": "number",
"description": "Total mass of all mounted equipment in grams."
},
"combined_noise_db_a": {
"type": "number",
"default": 0,
"description": "Logarithmic sum of acoustic noise emissions in dB(A) across all mounted devices."
},
"total_thermal_btu_hr": {
"type": "number",
"default": 0,
"description": "Total peak thermal dissipation in BTU/hr (1W = 3.41214 BTU/hr)."
},
"center_of_gravity_y_mm": {
"type": "number",
"description": "Vertical Center of Gravity height from bottom of U1 in millimeters."
},
"available_portal_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
"description": "1-indexed U slots that allow front-to-rear cable pass-through (open U or brush panel)."
}
},
"description": "Aggregated mechanical mass, center of gravity, thermal BTU/hr, and acoustic dB(A) metrics.",
"additionalProperties": false
}
},
"description": "Updated 5-stage validation report after mounting the device.",
"additionalProperties": false
},
"instance_id": {
"type": "string",
"description": "Target instance_id echoed when a pre-mount check fails."
},
"blueprint_slug": {
"type": "string",
"description": "Target blueprint_slug echoed when a pre-mount check fails."
},
"mounted_device": {
"anyOf": [
{
"type": "object",
"propertyNames": {
"type": "string"
},
"additionalProperties": {}
},
{
"type": "null"
}
],
"description": "Computed 3D world bounding boxes (chassis and plug clearance) and global port coordinates for the mounted device."
}
},
"description": "Equipment mounting result payload.",
"additionalProperties": {}
},
"issues": {
"type": "array",
"items": {
"type": "object",
"required": [
"code",
"severity",
"affected_instances",
"message",
"remediation_suggestions"
],
"properties": {
"code": {
"enum": [
"CHASSIS_COLLISION",
"PLUG_CLEARANCE_COLLISION",
"FRONT_DOOR_COLLISION",
"SLOT_DIMENSION_OVERFLOW",
"SLOT_INCOMPATIBLE",
"OUT_OF_RACK_BOUNDS",
"BLUEPRINT_NOT_FOUND",
"PORT_NOT_FOUND",
"PORT_ALREADY_OCCUPIED",
"CONNECTOR_INCOMPATIBLE",
"SIGNAL_PROTOCOL_INCOMPATIBLE",
"SPEED_MISMATCH",
"POE_BUDGET_EXCEEDED",
"POE_CLASS_EXCEEDED",
"UPS_OVERLOAD",
"UNPOWERED_DEVICE",
"TOP_HEAVY_RACK",
"NO_FRONT_TO_REAR_PORTAL",
"THERMAL_AIRFLOW_CONFLICT",
"THERMAL_HOTSPOT_STACKING",
"ACOUSTIC_NOISE_HIGH"
],
"type": "string",
"description": "Machine-readable deterministic validation diagnostic code."
},
"stage": {
"type": "integer",
"maximum": 5,
"minimum": 1,
"description": "Validation pipeline stage (1..5) that produced this finding."
},
"message": {
"type": "string",
"description": "Detailed engineering explanation with exact millimeter/watt figures."
},
"u_range": {
"type": "array",
"items": [
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
}
],
"maxItems": 2,
"minItems": 2,
"description": "Inclusive [start_u, end_u] range where the issue occurs.",
"additionalItems": false
},
"severity": {
"enum": [
"ERROR",
"WARNING",
"INFO"
],
"type": "string",
"description": "Severity level of the engineering constraint diagnostic."
},
"affected_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Device instance IDs involved in this diagnostic issue."
},
"remediation_actions": {
"type": "array",
"items": {
"type": "object",
"required": [
"action_type",
"description"
],
"properties": {
"action_type": {
"enum": [
"move_device",
"change_cable_type",
"connect_power",
"disconnect_cable",
"redistribute_poe",
"add_portal_gap",
"change_rack_depth"
],
"type": "string",
"description": "Recommended self-correction operation category."
},
"description": {
"type": "string",
"description": "Human- and agent-readable explanation of the remediation step."
},
"suggested_face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"target_cable_id": {
"type": "string",
"description": "Cable connection cable_id targeted by this remediation action."
},
"target_instance_id": {
"type": "string",
"description": "Device instance_id targeted by this remediation action."
},
"suggested_cable_type": {
"type": "string",
"description": "Suggested replacement cable_type (e.g. angled plug or higher speed grade)."
},
"suggested_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"exclusiveMinimum": 0
},
"description": "Candidate 1-indexed U positions that resolve the spatial conflict."
}
},
"description": "Structured self-correction action for autonomous agent remediation.",
"additionalProperties": false
},
"description": "Optional machine-actionable remediation descriptors."
},
"remediation_suggestions": {
"type": "array",
"items": {
"type": "string"
},
"minItems": 1,
"description": "Actionable self-correction instructions for the calling LLM agent."
}
},
"description": "Single validation finding with deterministic self-correction feedback.",
"additionalProperties": false
},
"description": "Structured diagnostic findings (ERROR, WARNING, INFO) with actionable remediation_suggestions."
},
"status": {
"enum": [
"VALID",
"INVALID"
],
"type": "string",
"description": "Deterministic execution outcome: \"VALID\" when the operation succeeded with 0 validation errors; \"INVALID\" when precondition or engineering validation errors are present in issues[]."
},
"summary": {
"type": "string",
"description": "Concise human- and agent-readable summary of the tool result and validation status."
}
},
"additionalProperties": false
},
"annotations": {
"title": "Mount Equipment into Rack Unit or Carrier Slot",
"readOnlyHint": false,
"openWorldHint": false,
"idempotentHint": false,
"destructiveHint": false
}
}Move, rename, or destructively remove an existing mounted device or child sub-module in the active rack, recalculate 3D cable splines, and re-run 5-stage validation. 'instance_id' resolves across top-level devices and carrier sub-modules, and required fields depend on 'action': 'move' updates 'u_position' and 'face' on rackmount gear or 'slot_id' and optional 'parent_carrier_id' across carriers for sub-modules with primary fields taking precedence over 'new_*' aliases, 'rename' updates or clears 'hostname', and 'remove' cascades to child sub-modules plus attached cables and external endpoints when 'remove_connected_cables' is true. Pushes the prior state onto the undo stack and updates rack.yaml atomically, or returns status 'INVALID' without mutating state when 'instance_id' or a target carrier is unknown. Use to update or delete a mounted instance; use mount_equipment to add new hardware, or disconnect_cables to remove cables while keeping devices mounted.
| Parameter | Type | Description |
|---|---|---|
| face | string | New mounting face ("front" or "rear") when action is "move" on a rackmount device (takes precedence over new_face). |
| action * | string | Modification operation: "move" relocates a device, "rename" updates its hostname, and "remove" deletes the device instance. |
| slot_id | string | Target slot_id inside parent_carrier_id when action is "move" on a child sub-module. |
| hostname | string | New logical hostname when action is "rename" (takes precedence over new_hostname). |
| new_face | string | Optional alias for face when action is "move". |
| u_position | integer | New 1-indexed U position when action is "move" on a direct rackmount device (takes precedence over new_u_position). |
| instance_id * | string | Existing mounted device or child sub-module instance_id to modify. |
| new_hostname | string | Optional alias for hostname when action is "rename". |
| new_u_position | integer | Optional alias for u_position when action is "move". |
| parent_carrier_id | string | Target parent carrier instance_id when action is "move" on a child sub-module. |
| remove_connected_cables | boolean | When action is "remove", whether to automatically disconnect all cables and external endpoints attached to the removed device (default: true). |
{
"name": "modify_equipment",
"title": "Move, Rename, or Remove Mounted Equipment",
"description": "Move, rename, or destructively remove an existing mounted device or child sub-module in the active rack, recalculate 3D cable splines, and re-run 5-stage validation. 'instance_id' resolves across top-level devices and carrier sub-modules, and required fields depend on 'action': 'move' updates 'u_position' and 'face' on rackmount gear or 'slot_id' and optional 'parent_carrier_id' across carriers for sub-modules with primary fields taking precedence over 'new_*' aliases, 'rename' updates or clears 'hostname', and 'remove' cascades to child sub-modules plus attached cables and external endpoints when 'remove_connected_cables' is true. Pushes the prior state onto the undo stack and updates rack.yaml atomically, or returns status 'INVALID' without mutating state when 'instance_id' or a target carrier is unknown. Use to update or delete a mounted instance; use mount_equipment to add new hardware, or disconnect_cables to remove cables while keeping devices mounted.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"instance_id",
"action"
],
"properties": {
"face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "New mounting face (\"front\" or \"rear\") when action is \"move\" on a rackmount device (takes precedence over new_face)."
},
"action": {
"enum": [
"move",
"rename",
"remove"
],
"type": "string",
"description": "Modification operation: \"move\" relocates a device, \"rename\" updates its hostname, and \"remove\" deletes the device instance."
},
"slot_id": {
"type": "string",
"maxLength": 100,
"minLength": 1,
"description": "Target slot_id inside parent_carrier_id when action is \"move\" on a child sub-module."
},
"hostname": {
"type": "string",
"maxLength": 160,
"minLength": 1,
"description": "New logical hostname when action is \"rename\" (takes precedence over new_hostname)."
},
"new_face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Optional alias for face when action is \"move\"."
},
"u_position": {
"type": "integer",
"maximum": 60,
"description": "New 1-indexed U position when action is \"move\" on a direct rackmount device (takes precedence over new_u_position).",
"exclusiveMinimum": 0
},
"instance_id": {
"type": "string",
"maxLength": 100,
"minLength": 1,
"description": "Existing mounted device or child sub-module instance_id to modify."
},
"new_hostname": {
"type": "string",
"maxLength": 160,
"minLength": 1,
"description": "Optional alias for hostname when action is \"rename\"."
},
"new_u_position": {
"type": "integer",
"maximum": 60,
"description": "Optional alias for u_position when action is \"move\".",
"exclusiveMinimum": 0
},
"parent_carrier_id": {
"type": "string",
"maxLength": 100,
"minLength": 1,
"description": "Target parent carrier instance_id when action is \"move\" on a child sub-module."
},
"remove_connected_cables": {
"type": "boolean",
"default": true,
"description": "When action is \"remove\", whether to automatically disconnect all cables and external endpoints attached to the removed device (default: true)."
}
}
},
"outputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"status",
"summary",
"data",
"issues"
],
"properties": {
"data": {
"type": "object",
"required": [
"instance_id"
],
"properties": {
"action": {
"enum": [
"move",
"rename",
"remove"
],
"type": "string",
"description": "Modification operation that was executed."
},
"validation": {
"type": "object",
"required": [
"status",
"is_valid",
"error_count",
"warning_count",
"issues",
"power_summary",
"mechanical_summary"
],
"properties": {
"issues": {
"type": "array",
"items": {
"type": "object",
"required": [
"code",
"severity",
"affected_instances",
"message",
"remediation_suggestions"
],
"properties": {
"code": {
"enum": [
"CHASSIS_COLLISION",
"PLUG_CLEARANCE_COLLISION",
"FRONT_DOOR_COLLISION",
"SLOT_DIMENSION_OVERFLOW",
"SLOT_INCOMPATIBLE",
"OUT_OF_RACK_BOUNDS",
"BLUEPRINT_NOT_FOUND",
"PORT_NOT_FOUND",
"PORT_ALREADY_OCCUPIED",
"CONNECTOR_INCOMPATIBLE",
"SIGNAL_PROTOCOL_INCOMPATIBLE",
"SPEED_MISMATCH",
"POE_BUDGET_EXCEEDED",
"POE_CLASS_EXCEEDED",
"UPS_OVERLOAD",
"UNPOWERED_DEVICE",
"TOP_HEAVY_RACK",
"NO_FRONT_TO_REAR_PORTAL",
"THERMAL_AIRFLOW_CONFLICT",
"THERMAL_HOTSPOT_STACKING",
"ACOUSTIC_NOISE_HIGH"
],
"type": "string",
"description": "Machine-readable deterministic validation diagnostic code."
},
"stage": {
"type": "integer",
"maximum": 5,
"minimum": 1,
"description": "Validation pipeline stage (1..5) that produced this finding."
},
"message": {
"type": "string",
"description": "Detailed engineering explanation with exact millimeter/watt figures."
},
"u_range": {
"type": "array",
"items": [
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
}
],
"maxItems": 2,
"minItems": 2,
"description": "Inclusive [start_u, end_u] range where the issue occurs.",
"additionalItems": false
},
"severity": {
"enum": [
"ERROR",
"WARNING",
"INFO"
],
"type": "string",
"description": "Severity level of the engineering constraint diagnostic."
},
"affected_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Device instance IDs involved in this diagnostic issue."
},
"remediation_actions": {
"type": "array",
"items": {
"type": "object",
"required": [
"action_type",
"description"
],
"properties": {
"action_type": {
"enum": [
"move_device",
"change_cable_type",
"connect_power",
"disconnect_cable",
"redistribute_poe",
"add_portal_gap",
"change_rack_depth"
],
"type": "string",
"description": "Recommended self-correction operation category."
},
"description": {
"type": "string",
"description": "Human- and agent-readable explanation of the remediation step."
},
"suggested_face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"target_cable_id": {
"type": "string",
"description": "Cable connection cable_id targeted by this remediation action."
},
"target_instance_id": {
"type": "string",
"description": "Device instance_id targeted by this remediation action."
},
"suggested_cable_type": {
"type": "string",
"description": "Suggested replacement cable_type (e.g. angled plug or higher speed grade)."
},
"suggested_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"exclusiveMinimum": 0
},
"description": "Candidate 1-indexed U positions that resolve the spatial conflict."
}
},
"description": "Structured self-correction action for autonomous agent remediation.",
"additionalProperties": false
},
"description": "Optional machine-actionable remediation descriptors."
},
"remediation_suggestions": {
"type": "array",
"items": {
"type": "string"
},
"minItems": 1,
"description": "Actionable self-correction instructions for the calling LLM agent."
}
},
"description": "Single validation finding with deterministic self-correction feedback.",
"additionalProperties": false
},
"description": "List of all detected ERROR, WARNING, and INFO diagnostic issues."
},
"status": {
"enum": [
"VALID",
"INVALID"
],
"type": "string",
"description": "Overall rack validation state (\"VALID\" when error_count is 0)."
},
"is_valid": {
"type": "boolean",
"description": "True when zero ERROR-level diagnostic issues exist."
},
"error_count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Total number of blocking ERROR diagnostics."
},
"power_summary": {
"type": "object",
"required": [
"total_system_watts",
"total_poe_watts",
"pse_budgets",
"power_sources",
"unpowered_active_instances"
],
"properties": {
"pse_budgets": {
"type": "array",
"items": {
"type": "object",
"required": [
"pse_instance_id",
"poe_budget_watts",
"consumed_poe_watts",
"remaining_poe_watts",
"downstream_devices"
],
"properties": {
"pse_instance_id": {
"type": "string",
"description": "Instance ID of the PoE Power Sourcing Equipment (PSE) switch."
},
"poe_budget_watts": {
"type": "number",
"description": "Maximum rated PoE output power budget of the switch in watts."
},
"consumed_poe_watts": {
"type": "number",
"description": "Total PoE power drawn by connected Powered Devices (PDs) in watts."
},
"downstream_devices": {
"type": "array",
"items": {
"type": "string"
},
"description": "Instance or endpoint IDs of downstream PoE consumers powered by this switch."
},
"remaining_poe_watts": {
"type": "number",
"description": "Remaining available PoE power budget in watts (negative if overloaded)."
}
},
"description": "PoE budget utilization breakdown for a single PSE switch.",
"additionalProperties": false
},
"description": "Per-switch PoE budget utilization breakdown."
},
"power_sources": {
"type": "array",
"items": {
"type": "object",
"required": [
"source_instance_id",
"role",
"capacity_watts",
"total_load_watts",
"utilization_percent"
],
"properties": {
"role": {
"enum": [
"pdu",
"ups"
],
"type": "string",
"description": "Electrical source classification (\"pdu\" or \"ups\")."
},
"capacity_watts": {
"type": "number",
"description": "Maximum rated output capacity of the power source in watts."
},
"total_load_watts": {
"type": "number",
"description": "Cumulative downstream system and PoE load in watts."
},
"source_instance_id": {
"type": "string",
"description": "Instance ID of the upstream PDU or UPS unit."
},
"utilization_percent": {
"type": "number",
"description": "Percentage of rated watt capacity consumed (0..100+)."
}
},
"description": "Load and capacity summary for a mounted PDU or UPS unit.",
"additionalProperties": false
},
"description": "Per-PDU and per-UPS electrical load breakdown."
},
"total_poe_watts": {
"type": "number",
"description": "Total PoE power draw across all connected PoE devices and external drops in watts."
},
"total_system_watts": {
"type": "number",
"description": "Total peak system power draw across all mounted equipment in watts."
},
"unpowered_active_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Active device instance IDs missing a valid AC, DC, USB-C, or PoE power input."
}
},
"description": "Aggregated electrical and PoE DAG power analysis.",
"additionalProperties": false
},
"warning_count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Total number of non-blocking WARNING diagnostics."
},
"mechanical_summary": {
"type": "object",
"required": [
"total_weight_grams",
"center_of_gravity_y_mm",
"normalized_cog_y",
"available_portal_u_positions",
"total_thermal_btu_hr",
"combined_noise_db_a",
"airflow_profile"
],
"properties": {
"airflow_profile": {
"enum": [
"uniform-front-to-rear",
"uniform-passive",
"hybrid-active-passive",
"mixed-conflict"
],
"type": "string",
"default": "uniform-passive",
"description": "Rack-wide thermal airflow regime classification."
},
"normalized_cog_y": {
"type": "number",
"description": "Normalized vertical Center of Gravity ratio (0.0 = bottom, 1.0 = top; keep <= 0.50)."
},
"total_weight_grams": {
"type": "number",
"description": "Total mass of all mounted equipment in grams."
},
"combined_noise_db_a": {
"type": "number",
"default": 0,
"description": "Logarithmic sum of acoustic noise emissions in dB(A) across all mounted devices."
},
"total_thermal_btu_hr": {
"type": "number",
"default": 0,
"description": "Total peak thermal dissipation in BTU/hr (1W = 3.41214 BTU/hr)."
},
"center_of_gravity_y_mm": {
"type": "number",
"description": "Vertical Center of Gravity height from bottom of U1 in millimeters."
},
"available_portal_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
"description": "1-indexed U slots that allow front-to-rear cable pass-through (open U or brush panel)."
}
},
"description": "Aggregated mechanical mass, center of gravity, thermal BTU/hr, and acoustic dB(A) metrics.",
"additionalProperties": false
}
},
"description": "Updated 5-stage validation report after the equipment modification.",
"additionalProperties": false
},
"instance_id": {
"type": "string",
"description": "Target mounted device or sub-module instance_id."
},
"updated_device": {
"anyOf": [
{
"type": "object",
"propertyNames": {
"type": "string"
},
"additionalProperties": {}
},
{
"type": "null"
}
],
"description": "Updated 3D world geometry of the device, or null if removed."
},
"rerouted_cables": {
"type": "array",
"items": {
"type": "object",
"required": [
"cable_id",
"raw_arc_length_mm",
"required_length_mm",
"recommended_commercial_mm"
],
"properties": {
"cable_id": {
"type": "string",
"description": "Cable connection identifier."
},
"raw_arc_length_mm": {
"type": "number",
"description": "Recalculated 3D spline arc length in mm."
},
"required_length_mm": {
"type": "number",
"description": "Required cable length with slack in mm."
},
"recommended_commercial_mm": {
"type": "number",
"description": "Standard commercial cable length bin in mm."
}
},
"additionalProperties": {}
},
"description": "Recalculated 3D cable length summaries after moving or removing equipment."
},
"removed_cable_ids": {
"type": "array",
"items": {
"type": "string"
},
"description": "Cable IDs automatically disconnected when action is \"remove\"."
}
},
"description": "Equipment modification result payload.",
"additionalProperties": {}
},
"issues": {
"type": "array",
"items": {
"type": "object",
"required": [
"code",
"severity",
"affected_instances",
"message",
"remediation_suggestions"
],
"properties": {
"code": {
"enum": [
"CHASSIS_COLLISION",
"PLUG_CLEARANCE_COLLISION",
"FRONT_DOOR_COLLISION",
"SLOT_DIMENSION_OVERFLOW",
"SLOT_INCOMPATIBLE",
"OUT_OF_RACK_BOUNDS",
"BLUEPRINT_NOT_FOUND",
"PORT_NOT_FOUND",
"PORT_ALREADY_OCCUPIED",
"CONNECTOR_INCOMPATIBLE",
"SIGNAL_PROTOCOL_INCOMPATIBLE",
"SPEED_MISMATCH",
"POE_BUDGET_EXCEEDED",
"POE_CLASS_EXCEEDED",
"UPS_OVERLOAD",
"UNPOWERED_DEVICE",
"TOP_HEAVY_RACK",
"NO_FRONT_TO_REAR_PORTAL",
"THERMAL_AIRFLOW_CONFLICT",
"THERMAL_HOTSPOT_STACKING",
"ACOUSTIC_NOISE_HIGH"
],
"type": "string",
"description": "Machine-readable deterministic validation diagnostic code."
},
"stage": {
"type": "integer",
"maximum": 5,
"minimum": 1,
"description": "Validation pipeline stage (1..5) that produced this finding."
},
"message": {
"type": "string",
"description": "Detailed engineering explanation with exact millimeter/watt figures."
},
"u_range": {
"type": "array",
"items": [
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
}
],
"maxItems": 2,
"minItems": 2,
"description": "Inclusive [start_u, end_u] range where the issue occurs.",
"additionalItems": false
},
"severity": {
"enum": [
"ERROR",
"WARNING",
"INFO"
],
"type": "string",
"description": "Severity level of the engineering constraint diagnostic."
},
"affected_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Device instance IDs involved in this diagnostic issue."
},
"remediation_actions": {
"type": "array",
"items": {
"type": "object",
"required": [
"action_type",
"description"
],
"properties": {
"action_type": {
"enum": [
"move_device",
"change_cable_type",
"connect_power",
"disconnect_cable",
"redistribute_poe",
"add_portal_gap",
"change_rack_depth"
],
"type": "string",
"description": "Recommended self-correction operation category."
},
"description": {
"type": "string",
"description": "Human- and agent-readable explanation of the remediation step."
},
"suggested_face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"target_cable_id": {
"type": "string",
"description": "Cable connection cable_id targeted by this remediation action."
},
"target_instance_id": {
"type": "string",
"description": "Device instance_id targeted by this remediation action."
},
"suggested_cable_type": {
"type": "string",
"description": "Suggested replacement cable_type (e.g. angled plug or higher speed grade)."
},
"suggested_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"exclusiveMinimum": 0
},
"description": "Candidate 1-indexed U positions that resolve the spatial conflict."
}
},
"description": "Structured self-correction action for autonomous agent remediation.",
"additionalProperties": false
},
"description": "Optional machine-actionable remediation descriptors."
},
"remediation_suggestions": {
"type": "array",
"items": {
"type": "string"
},
"minItems": 1,
"description": "Actionable self-correction instructions for the calling LLM agent."
}
},
"description": "Single validation finding with deterministic self-correction feedback.",
"additionalProperties": false
},
"description": "Structured diagnostic findings (ERROR, WARNING, INFO) with actionable remediation_suggestions."
},
"status": {
"enum": [
"VALID",
"INVALID"
],
"type": "string",
"description": "Deterministic execution outcome: \"VALID\" when the operation succeeded with 0 validation errors; \"INVALID\" when precondition or engineering validation errors are present in issues[]."
},
"summary": {
"type": "string",
"description": "Concise human- and agent-readable summary of the tool result and validation status."
}
},
"additionalProperties": false
},
"annotations": {
"title": "Move, Rename, or Remove Mounted Equipment",
"readOnlyHint": false,
"openWorldHint": false,
"idempotentHint": false,
"destructiveHint": true
}
}Connect or update a batch of up to 128 power and network cables between mounted device ports in the active rack, computing 3D Catmull-Rom splines, commercial length bins, and PoE or power budgets. Each entry in 'cables[]' upserts in place by 'cable_id' while leaving all other cables and mounted equipment untouched, pushes a recoverable undo snapshot, and persists rack.yaml atomically; port, speed, PoE, or clearance violations return status 'INVALID' with remediation_suggestions instead of throwing. Within each cable, endpoint 'face' is required only on pass-through couplers such as patch panels exposing identical 'port_id' values on both faces, 'preferred_portal_u' applies only to front-to-rear transitions, and 'vlan_id' or 'ip_cidr' annotate logical network links. Use when both endpoint devices are mounted inside the rack; use disconnect_cables to remove cables, or plan_external_endpoints to terminate incoming building cable drops on a patch panel.
| Parameter | Type | Description |
|---|---|---|
| cables * | array | Batch of one or more cable connections to upsert by cable_id, route in 3D, and validate (max 128 per call). |
{
"name": "connect_cables",
"title": "Connect and Route Inter-Device Cables",
"description": "Connect or update a batch of up to 128 power and network cables between mounted device ports in the active rack, computing 3D Catmull-Rom splines, commercial length bins, and PoE or power budgets. Each entry in 'cables[]' upserts in place by 'cable_id' while leaving all other cables and mounted equipment untouched, pushes a recoverable undo snapshot, and persists rack.yaml atomically; port, speed, PoE, or clearance violations return status 'INVALID' with remediation_suggestions instead of throwing. Within each cable, endpoint 'face' is required only on pass-through couplers such as patch panels exposing identical 'port_id' values on both faces, 'preferred_portal_u' applies only to front-to-rear transitions, and 'vlan_id' or 'ip_cidr' annotate logical network links. Use when both endpoint devices are mounted inside the rack; use disconnect_cables to remove cables, or plan_external_endpoints to terminate incoming building cable drops on a patch panel.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"cables"
],
"properties": {
"cables": {
"type": "array",
"items": {
"type": "object",
"required": [
"cable_id",
"from",
"to",
"cable_type"
],
"properties": {
"to": {
"type": "object",
"required": [
"instance_id",
"port_id"
],
"properties": {
"face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Explicit rack face selector (used to distinguish front vs rear connections on passthrough couplers)."
},
"port_id": {
"type": "string",
"maxLength": 128,
"minLength": 1,
"description": "Target port_id on the device."
},
"instance_id": {
"type": "string",
"maxLength": 100,
"minLength": 1,
"description": "Target device instance_id (top-level or child sub-module)."
}
},
"description": "Source or destination port endpoint of a physical cable."
},
"from": {
"type": "object",
"required": [
"instance_id",
"port_id"
],
"properties": {
"face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Explicit rack face selector (used to distinguish front vs rear connections on passthrough couplers)."
},
"port_id": {
"type": "string",
"maxLength": 128,
"minLength": 1,
"description": "Target port_id on the device."
},
"instance_id": {
"type": "string",
"maxLength": 100,
"minLength": 1,
"description": "Target device instance_id (top-level or child sub-module)."
}
},
"description": "Source or destination port endpoint of a physical cable."
},
"label": {
"type": "string",
"maxLength": 240,
"description": "Optional cable label or circuit tag."
},
"ip_cidr": {
"type": "string",
"maxLength": 64,
"description": "Optional IPv4/IPv6 subnet or interface CIDR annotation (e.g. \"10.10.20.0/24\")."
},
"vlan_id": {
"type": "integer",
"maximum": 4094,
"minimum": 1,
"description": "Optional IEEE 802.1Q primary VLAN ID carried on this link (1..4094)."
},
"cable_id": {
"type": "string",
"maxLength": 128,
"minLength": 1,
"description": "Unique identifier for the cable connection."
},
"color_hex": {
"type": "string",
"default": "#3B82F6",
"pattern": "^#[0-9A-Fa-f]{6}$",
"description": "Hex color code for 2D/3D cable visualization."
},
"cable_type": {
"enum": [
"cat6a",
"cat6a-angled",
"cat6",
"cat6-angled",
"cat5e",
"cat5e-angled",
"sfp-plus-dac",
"sfp-plus-dac-angled",
"fiber-lc-duplex",
"fiber-lc-duplex-angled",
"rj45-serial-rollover",
"rj45-serial-rollover-angled",
"power-c13-c14",
"power-c13-c14-angled",
"power-schuko-c13",
"power-schuko-c13-angled",
"power-dc-5525",
"power-dc-5525-angled",
"power-usb-c",
"power-usb-c-angled"
],
"type": "string",
"description": "Standardized physical cable and connector assembly type."
},
"routing_mode": {
"enum": [
"shortest-direct",
"left-duct",
"right-duct"
],
"type": "string",
"default": "shortest-direct",
"description": "Optional routing strategy override: defaults to shortest-direct (shortest collision-free path); set to left-duct or right-duct only when the user explicitly requests routing via a side cable duct."
},
"preferred_portal_u": {
"type": "integer",
"maximum": 60,
"description": "Optional 1-indexed U hint for front-to-rear cable portal routing.",
"exclusiveMinimum": 0
}
},
"description": "Point-to-point physical cable connection between two ports."
},
"maxItems": 128,
"minItems": 1,
"description": "Batch of one or more cable connections to upsert by cable_id, route in 3D, and validate (max 128 per call)."
}
}
},
"outputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"status",
"summary",
"data",
"issues"
],
"properties": {
"data": {
"type": "object",
"required": [
"connected_cables",
"total_cables",
"validation"
],
"properties": {
"validation": {
"type": "object",
"required": [
"status",
"is_valid",
"error_count",
"warning_count",
"issues",
"power_summary",
"mechanical_summary"
],
"properties": {
"issues": {
"type": "array",
"items": {
"type": "object",
"required": [
"code",
"severity",
"affected_instances",
"message",
"remediation_suggestions"
],
"properties": {
"code": {
"enum": [
"CHASSIS_COLLISION",
"PLUG_CLEARANCE_COLLISION",
"FRONT_DOOR_COLLISION",
"SLOT_DIMENSION_OVERFLOW",
"SLOT_INCOMPATIBLE",
"OUT_OF_RACK_BOUNDS",
"BLUEPRINT_NOT_FOUND",
"PORT_NOT_FOUND",
"PORT_ALREADY_OCCUPIED",
"CONNECTOR_INCOMPATIBLE",
"SIGNAL_PROTOCOL_INCOMPATIBLE",
"SPEED_MISMATCH",
"POE_BUDGET_EXCEEDED",
"POE_CLASS_EXCEEDED",
"UPS_OVERLOAD",
"UNPOWERED_DEVICE",
"TOP_HEAVY_RACK",
"NO_FRONT_TO_REAR_PORTAL",
"THERMAL_AIRFLOW_CONFLICT",
"THERMAL_HOTSPOT_STACKING",
"ACOUSTIC_NOISE_HIGH"
],
"type": "string",
"description": "Machine-readable deterministic validation diagnostic code."
},
"stage": {
"type": "integer",
"maximum": 5,
"minimum": 1,
"description": "Validation pipeline stage (1..5) that produced this finding."
},
"message": {
"type": "string",
"description": "Detailed engineering explanation with exact millimeter/watt figures."
},
"u_range": {
"type": "array",
"items": [
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
}
],
"maxItems": 2,
"minItems": 2,
"description": "Inclusive [start_u, end_u] range where the issue occurs.",
"additionalItems": false
},
"severity": {
"enum": [
"ERROR",
"WARNING",
"INFO"
],
"type": "string",
"description": "Severity level of the engineering constraint diagnostic."
},
"affected_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Device instance IDs involved in this diagnostic issue."
},
"remediation_actions": {
"type": "array",
"items": {
"type": "object",
"required": [
"action_type",
"description"
],
"properties": {
"action_type": {
"enum": [
"move_device",
"change_cable_type",
"connect_power",
"disconnect_cable",
"redistribute_poe",
"add_portal_gap",
"change_rack_depth"
],
"type": "string",
"description": "Recommended self-correction operation category."
},
"description": {
"type": "string",
"description": "Human- and agent-readable explanation of the remediation step."
},
"suggested_face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"target_cable_id": {
"type": "string",
"description": "Cable connection cable_id targeted by this remediation action."
},
"target_instance_id": {
"type": "string",
"description": "Device instance_id targeted by this remediation action."
},
"suggested_cable_type": {
"type": "string",
"description": "Suggested replacement cable_type (e.g. angled plug or higher speed grade)."
},
"suggested_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"exclusiveMinimum": 0
},
"description": "Candidate 1-indexed U positions that resolve the spatial conflict."
}
},
"description": "Structured self-correction action for autonomous agent remediation.",
"additionalProperties": false
},
"description": "Optional machine-actionable remediation descriptors."
},
"remediation_suggestions": {
"type": "array",
"items": {
"type": "string"
},
"minItems": 1,
"description": "Actionable self-correction instructions for the calling LLM agent."
}
},
"description": "Single validation finding with deterministic self-correction feedback.",
"additionalProperties": false
},
"description": "List of all detected ERROR, WARNING, and INFO diagnostic issues."
},
"status": {
"enum": [
"VALID",
"INVALID"
],
"type": "string",
"description": "Overall rack validation state (\"VALID\" when error_count is 0)."
},
"is_valid": {
"type": "boolean",
"description": "True when zero ERROR-level diagnostic issues exist."
},
"error_count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Total number of blocking ERROR diagnostics."
},
"power_summary": {
"type": "object",
"required": [
"total_system_watts",
"total_poe_watts",
"pse_budgets",
"power_sources",
"unpowered_active_instances"
],
"properties": {
"pse_budgets": {
"type": "array",
"items": {
"type": "object",
"required": [
"pse_instance_id",
"poe_budget_watts",
"consumed_poe_watts",
"remaining_poe_watts",
"downstream_devices"
],
"properties": {
"pse_instance_id": {
"type": "string",
"description": "Instance ID of the PoE Power Sourcing Equipment (PSE) switch."
},
"poe_budget_watts": {
"type": "number",
"description": "Maximum rated PoE output power budget of the switch in watts."
},
"consumed_poe_watts": {
"type": "number",
"description": "Total PoE power drawn by connected Powered Devices (PDs) in watts."
},
"downstream_devices": {
"type": "array",
"items": {
"type": "string"
},
"description": "Instance or endpoint IDs of downstream PoE consumers powered by this switch."
},
"remaining_poe_watts": {
"type": "number",
"description": "Remaining available PoE power budget in watts (negative if overloaded)."
}
},
"description": "PoE budget utilization breakdown for a single PSE switch.",
"additionalProperties": false
},
"description": "Per-switch PoE budget utilization breakdown."
},
"power_sources": {
"type": "array",
"items": {
"type": "object",
"required": [
"source_instance_id",
"role",
"capacity_watts",
"total_load_watts",
"utilization_percent"
],
"properties": {
"role": {
"enum": [
"pdu",
"ups"
],
"type": "string",
"description": "Electrical source classification (\"pdu\" or \"ups\")."
},
"capacity_watts": {
"type": "number",
"description": "Maximum rated output capacity of the power source in watts."
},
"total_load_watts": {
"type": "number",
"description": "Cumulative downstream system and PoE load in watts."
},
"source_instance_id": {
"type": "string",
"description": "Instance ID of the upstream PDU or UPS unit."
},
"utilization_percent": {
"type": "number",
"description": "Percentage of rated watt capacity consumed (0..100+)."
}
},
"description": "Load and capacity summary for a mounted PDU or UPS unit.",
"additionalProperties": false
},
"description": "Per-PDU and per-UPS electrical load breakdown."
},
"total_poe_watts": {
"type": "number",
"description": "Total PoE power draw across all connected PoE devices and external drops in watts."
},
"total_system_watts": {
"type": "number",
"description": "Total peak system power draw across all mounted equipment in watts."
},
"unpowered_active_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Active device instance IDs missing a valid AC, DC, USB-C, or PoE power input."
}
},
"description": "Aggregated electrical and PoE DAG power analysis.",
"additionalProperties": false
},
"warning_count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Total number of non-blocking WARNING diagnostics."
},
"mechanical_summary": {
"type": "object",
"required": [
"total_weight_grams",
"center_of_gravity_y_mm",
"normalized_cog_y",
"available_portal_u_positions",
"total_thermal_btu_hr",
"combined_noise_db_a",
"airflow_profile"
],
"properties": {
"airflow_profile": {
"enum": [
"uniform-front-to-rear",
"uniform-passive",
"hybrid-active-passive",
"mixed-conflict"
],
"type": "string",
"default": "uniform-passive",
"description": "Rack-wide thermal airflow regime classification."
},
"normalized_cog_y": {
"type": "number",
"description": "Normalized vertical Center of Gravity ratio (0.0 = bottom, 1.0 = top; keep <= 0.50)."
},
"total_weight_grams": {
"type": "number",
"description": "Total mass of all mounted equipment in grams."
},
"combined_noise_db_a": {
"type": "number",
"default": 0,
"description": "Logarithmic sum of acoustic noise emissions in dB(A) across all mounted devices."
},
"total_thermal_btu_hr": {
"type": "number",
"default": 0,
"description": "Total peak thermal dissipation in BTU/hr (1W = 3.41214 BTU/hr)."
},
"center_of_gravity_y_mm": {
"type": "number",
"description": "Vertical Center of Gravity height from bottom of U1 in millimeters."
},
"available_portal_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
"description": "1-indexed U slots that allow front-to-rear cable pass-through (open U or brush panel)."
}
},
"description": "Aggregated mechanical mass, center of gravity, thermal BTU/hr, and acoustic dB(A) metrics.",
"additionalProperties": false
}
},
"description": "Updated 5-stage validation report including port, speed, PoE budget, and plug clearance checks.",
"additionalProperties": false
},
"total_cables": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Total number of active cables in the rack project."
},
"connected_cables": {
"type": "array",
"items": {
"type": "object",
"required": [
"cable_id",
"cable_type",
"route_case",
"raw_arc_length_mm",
"required_length_mm",
"recommended_commercial_mm"
],
"properties": {
"cable_id": {
"type": "string",
"description": "Unique cable identifier."
},
"portal_u": {
"type": [
"number",
"null"
],
"description": "1-indexed U position of the front-to-rear cable portal if traversed."
},
"cable_type": {
"enum": [
"cat6a",
"cat6a-angled",
"cat6",
"cat6-angled",
"cat5e",
"cat5e-angled",
"sfp-plus-dac",
"sfp-plus-dac-angled",
"fiber-lc-duplex",
"fiber-lc-duplex-angled",
"rj45-serial-rollover",
"rj45-serial-rollover-angled",
"power-c13-c14",
"power-c13-c14-angled",
"power-schuko-c13",
"power-schuko-c13-angled",
"power-dc-5525",
"power-dc-5525-angled",
"power-usb-c",
"power-usb-c-angled"
],
"type": "string",
"description": "Standardized physical cable and connector assembly type."
},
"route_case": {
"type": "string",
"description": "Computed 3D spline routing topology class."
},
"assigned_ducts": {
"type": "array",
"items": {
"type": "string"
},
"description": "Cable ducts traversed along the route."
},
"raw_arc_length_mm": {
"type": "number",
"description": "3D Catmull-Rom spline arc length in mm."
},
"required_length_mm": {
"type": "number",
"description": "Required length including slack in mm."
},
"recommended_commercial_mm": {
"type": "number",
"description": "Standard commercial patch cable length bin in mm."
}
},
"additionalProperties": {}
},
"description": "Computed 3D spline route metrics and commercial SKU length bins for the connected cables."
}
},
"description": "Cable connection and 3D routing result payload.",
"additionalProperties": {}
},
"issues": {
"type": "array",
"items": {
"type": "object",
"required": [
"code",
"severity",
"affected_instances",
"message",
"remediation_suggestions"
],
"properties": {
"code": {
"enum": [
"CHASSIS_COLLISION",
"PLUG_CLEARANCE_COLLISION",
"FRONT_DOOR_COLLISION",
"SLOT_DIMENSION_OVERFLOW",
"SLOT_INCOMPATIBLE",
"OUT_OF_RACK_BOUNDS",
"BLUEPRINT_NOT_FOUND",
"PORT_NOT_FOUND",
"PORT_ALREADY_OCCUPIED",
"CONNECTOR_INCOMPATIBLE",
"SIGNAL_PROTOCOL_INCOMPATIBLE",
"SPEED_MISMATCH",
"POE_BUDGET_EXCEEDED",
"POE_CLASS_EXCEEDED",
"UPS_OVERLOAD",
"UNPOWERED_DEVICE",
"TOP_HEAVY_RACK",
"NO_FRONT_TO_REAR_PORTAL",
"THERMAL_AIRFLOW_CONFLICT",
"THERMAL_HOTSPOT_STACKING",
"ACOUSTIC_NOISE_HIGH"
],
"type": "string",
"description": "Machine-readable deterministic validation diagnostic code."
},
"stage": {
"type": "integer",
"maximum": 5,
"minimum": 1,
"description": "Validation pipeline stage (1..5) that produced this finding."
},
"message": {
"type": "string",
"description": "Detailed engineering explanation with exact millimeter/watt figures."
},
"u_range": {
"type": "array",
"items": [
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
}
],
"maxItems": 2,
"minItems": 2,
"description": "Inclusive [start_u, end_u] range where the issue occurs.",
"additionalItems": false
},
"severity": {
"enum": [
"ERROR",
"WARNING",
"INFO"
],
"type": "string",
"description": "Severity level of the engineering constraint diagnostic."
},
"affected_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Device instance IDs involved in this diagnostic issue."
},
"remediation_actions": {
"type": "array",
"items": {
"type": "object",
"required": [
"action_type",
"description"
],
"properties": {
"action_type": {
"enum": [
"move_device",
"change_cable_type",
"connect_power",
"disconnect_cable",
"redistribute_poe",
"add_portal_gap",
"change_rack_depth"
],
"type": "string",
"description": "Recommended self-correction operation category."
},
"description": {
"type": "string",
"description": "Human- and agent-readable explanation of the remediation step."
},
"suggested_face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"target_cable_id": {
"type": "string",
"description": "Cable connection cable_id targeted by this remediation action."
},
"target_instance_id": {
"type": "string",
"description": "Device instance_id targeted by this remediation action."
},
"suggested_cable_type": {
"type": "string",
"description": "Suggested replacement cable_type (e.g. angled plug or higher speed grade)."
},
"suggested_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"exclusiveMinimum": 0
},
"description": "Candidate 1-indexed U positions that resolve the spatial conflict."
}
},
"description": "Structured self-correction action for autonomous agent remediation.",
"additionalProperties": false
},
"description": "Optional machine-actionable remediation descriptors."
},
"remediation_suggestions": {
"type": "array",
"items": {
"type": "string"
},
"minItems": 1,
"description": "Actionable self-correction instructions for the calling LLM agent."
}
},
"description": "Single validation finding with deterministic self-correction feedback.",
"additionalProperties": false
},
"description": "Structured diagnostic findings (ERROR, WARNING, INFO) with actionable remediation_suggestions."
},
"status": {
"enum": [
"VALID",
"INVALID"
],
"type": "string",
"description": "Deterministic execution outcome: \"VALID\" when the operation succeeded with 0 validation errors; \"INVALID\" when precondition or engineering validation errors are present in issues[]."
},
"summary": {
"type": "string",
"description": "Concise human- and agent-readable summary of the tool result and validation status."
}
},
"additionalProperties": false
},
"annotations": {
"title": "Connect and Route Inter-Device Cables",
"readOnlyHint": false,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Remove specific cables by identifier or strip all cables attached to a mounted device or modular carrier from the active rack, then re-evaluate PoE budgets and plug clearances. Supply a non-empty 'cable_ids' list, 'instance_id', or both to disconnect their union; 'instance_id' matches both 'from' and 'to' endpoints across a carrier and its child sub-modules while leaving external patch-panel drops intact, whereas omitting both or passing only an empty list returns status 'INVALID' with a PORT_NOT_FOUND issue and zero mutations. Valid calls push an undo snapshot, persist rack.yaml atomically, and return removed IDs, remaining cable count, and updated validation results, succeeding idempotently when targeted IDs are already absent. Use when rewiring ports while keeping hardware mounted; use connect_cables to add or replace cables, or modify_equipment with action 'remove' to delete a device and its cables.
| Parameter | Type | Description |
|---|---|---|
| cable_ids | array | Specific cable_id values to disconnect (can be combined with instance_id; at least one of cable_ids or instance_id must be provided). |
| instance_id | string | Mounted device or modular-carrier instance_id whose attached cables (including child sub-module cables) should all be disconnected. |
{
"name": "disconnect_cables",
"title": "Disconnect Cables by ID or Device Instance",
"description": "Remove specific cables by identifier or strip all cables attached to a mounted device or modular carrier from the active rack, then re-evaluate PoE budgets and plug clearances. Supply a non-empty 'cable_ids' list, 'instance_id', or both to disconnect their union; 'instance_id' matches both 'from' and 'to' endpoints across a carrier and its child sub-modules while leaving external patch-panel drops intact, whereas omitting both or passing only an empty list returns status 'INVALID' with a PORT_NOT_FOUND issue and zero mutations. Valid calls push an undo snapshot, persist rack.yaml atomically, and return removed IDs, remaining cable count, and updated validation results, succeeding idempotently when targeted IDs are already absent. Use when rewiring ports while keeping hardware mounted; use connect_cables to add or replace cables, or modify_equipment with action 'remove' to delete a device and its cables.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"properties": {
"cable_ids": {
"type": "array",
"items": {
"type": "string",
"maxLength": 128,
"minLength": 1
},
"maxItems": 512,
"description": "Specific cable_id values to disconnect (can be combined with instance_id; at least one of cable_ids or instance_id must be provided)."
},
"instance_id": {
"type": "string",
"maxLength": 100,
"description": "Mounted device or modular-carrier instance_id whose attached cables (including child sub-module cables) should all be disconnected."
}
}
},
"outputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"status",
"summary",
"data",
"issues"
],
"properties": {
"data": {
"type": "object",
"required": [
"removed_cable_ids",
"remaining_cables_count"
],
"properties": {
"validation": {
"type": "object",
"required": [
"status",
"is_valid",
"error_count",
"warning_count",
"issues",
"power_summary",
"mechanical_summary"
],
"properties": {
"issues": {
"type": "array",
"items": {
"type": "object",
"required": [
"code",
"severity",
"affected_instances",
"message",
"remediation_suggestions"
],
"properties": {
"code": {
"enum": [
"CHASSIS_COLLISION",
"PLUG_CLEARANCE_COLLISION",
"FRONT_DOOR_COLLISION",
"SLOT_DIMENSION_OVERFLOW",
"SLOT_INCOMPATIBLE",
"OUT_OF_RACK_BOUNDS",
"BLUEPRINT_NOT_FOUND",
"PORT_NOT_FOUND",
"PORT_ALREADY_OCCUPIED",
"CONNECTOR_INCOMPATIBLE",
"SIGNAL_PROTOCOL_INCOMPATIBLE",
"SPEED_MISMATCH",
"POE_BUDGET_EXCEEDED",
"POE_CLASS_EXCEEDED",
"UPS_OVERLOAD",
"UNPOWERED_DEVICE",
"TOP_HEAVY_RACK",
"NO_FRONT_TO_REAR_PORTAL",
"THERMAL_AIRFLOW_CONFLICT",
"THERMAL_HOTSPOT_STACKING",
"ACOUSTIC_NOISE_HIGH"
],
"type": "string",
"description": "Machine-readable deterministic validation diagnostic code."
},
"stage": {
"type": "integer",
"maximum": 5,
"minimum": 1,
"description": "Validation pipeline stage (1..5) that produced this finding."
},
"message": {
"type": "string",
"description": "Detailed engineering explanation with exact millimeter/watt figures."
},
"u_range": {
"type": "array",
"items": [
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
}
],
"maxItems": 2,
"minItems": 2,
"description": "Inclusive [start_u, end_u] range where the issue occurs.",
"additionalItems": false
},
"severity": {
"enum": [
"ERROR",
"WARNING",
"INFO"
],
"type": "string",
"description": "Severity level of the engineering constraint diagnostic."
},
"affected_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Device instance IDs involved in this diagnostic issue."
},
"remediation_actions": {
"type": "array",
"items": {
"type": "object",
"required": [
"action_type",
"description"
],
"properties": {
"action_type": {
"enum": [
"move_device",
"change_cable_type",
"connect_power",
"disconnect_cable",
"redistribute_poe",
"add_portal_gap",
"change_rack_depth"
],
"type": "string",
"description": "Recommended self-correction operation category."
},
"description": {
"type": "string",
"description": "Human- and agent-readable explanation of the remediation step."
},
"suggested_face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"target_cable_id": {
"type": "string",
"description": "Cable connection cable_id targeted by this remediation action."
},
"target_instance_id": {
"type": "string",
"description": "Device instance_id targeted by this remediation action."
},
"suggested_cable_type": {
"type": "string",
"description": "Suggested replacement cable_type (e.g. angled plug or higher speed grade)."
},
"suggested_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"exclusiveMinimum": 0
},
"description": "Candidate 1-indexed U positions that resolve the spatial conflict."
}
},
"description": "Structured self-correction action for autonomous agent remediation.",
"additionalProperties": false
},
"description": "Optional machine-actionable remediation descriptors."
},
"remediation_suggestions": {
"type": "array",
"items": {
"type": "string"
},
"minItems": 1,
"description": "Actionable self-correction instructions for the calling LLM agent."
}
},
"description": "Single validation finding with deterministic self-correction feedback.",
"additionalProperties": false
},
"description": "List of all detected ERROR, WARNING, and INFO diagnostic issues."
},
"status": {
"enum": [
"VALID",
"INVALID"
],
"type": "string",
"description": "Overall rack validation state (\"VALID\" when error_count is 0)."
},
"is_valid": {
"type": "boolean",
"description": "True when zero ERROR-level diagnostic issues exist."
},
"error_count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Total number of blocking ERROR diagnostics."
},
"power_summary": {
"type": "object",
"required": [
"total_system_watts",
"total_poe_watts",
"pse_budgets",
"power_sources",
"unpowered_active_instances"
],
"properties": {
"pse_budgets": {
"type": "array",
"items": {
"type": "object",
"required": [
"pse_instance_id",
"poe_budget_watts",
"consumed_poe_watts",
"remaining_poe_watts",
"downstream_devices"
],
"properties": {
"pse_instance_id": {
"type": "string",
"description": "Instance ID of the PoE Power Sourcing Equipment (PSE) switch."
},
"poe_budget_watts": {
"type": "number",
"description": "Maximum rated PoE output power budget of the switch in watts."
},
"consumed_poe_watts": {
"type": "number",
"description": "Total PoE power drawn by connected Powered Devices (PDs) in watts."
},
"downstream_devices": {
"type": "array",
"items": {
"type": "string"
},
"description": "Instance or endpoint IDs of downstream PoE consumers powered by this switch."
},
"remaining_poe_watts": {
"type": "number",
"description": "Remaining available PoE power budget in watts (negative if overloaded)."
}
},
"description": "PoE budget utilization breakdown for a single PSE switch.",
"additionalProperties": false
},
"description": "Per-switch PoE budget utilization breakdown."
},
"power_sources": {
"type": "array",
"items": {
"type": "object",
"required": [
"source_instance_id",
"role",
"capacity_watts",
"total_load_watts",
"utilization_percent"
],
"properties": {
"role": {
"enum": [
"pdu",
"ups"
],
"type": "string",
"description": "Electrical source classification (\"pdu\" or \"ups\")."
},
"capacity_watts": {
"type": "number",
"description": "Maximum rated output capacity of the power source in watts."
},
"total_load_watts": {
"type": "number",
"description": "Cumulative downstream system and PoE load in watts."
},
"source_instance_id": {
"type": "string",
"description": "Instance ID of the upstream PDU or UPS unit."
},
"utilization_percent": {
"type": "number",
"description": "Percentage of rated watt capacity consumed (0..100+)."
}
},
"description": "Load and capacity summary for a mounted PDU or UPS unit.",
"additionalProperties": false
},
"description": "Per-PDU and per-UPS electrical load breakdown."
},
"total_poe_watts": {
"type": "number",
"description": "Total PoE power draw across all connected PoE devices and external drops in watts."
},
"total_system_watts": {
"type": "number",
"description": "Total peak system power draw across all mounted equipment in watts."
},
"unpowered_active_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Active device instance IDs missing a valid AC, DC, USB-C, or PoE power input."
}
},
"description": "Aggregated electrical and PoE DAG power analysis.",
"additionalProperties": false
},
"warning_count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Total number of non-blocking WARNING diagnostics."
},
"mechanical_summary": {
"type": "object",
"required": [
"total_weight_grams",
"center_of_gravity_y_mm",
"normalized_cog_y",
"available_portal_u_positions",
"total_thermal_btu_hr",
"combined_noise_db_a",
"airflow_profile"
],
"properties": {
"airflow_profile": {
"enum": [
"uniform-front-to-rear",
"uniform-passive",
"hybrid-active-passive",
"mixed-conflict"
],
"type": "string",
"default": "uniform-passive",
"description": "Rack-wide thermal airflow regime classification."
},
"normalized_cog_y": {
"type": "number",
"description": "Normalized vertical Center of Gravity ratio (0.0 = bottom, 1.0 = top; keep <= 0.50)."
},
"total_weight_grams": {
"type": "number",
"description": "Total mass of all mounted equipment in grams."
},
"combined_noise_db_a": {
"type": "number",
"default": 0,
"description": "Logarithmic sum of acoustic noise emissions in dB(A) across all mounted devices."
},
"total_thermal_btu_hr": {
"type": "number",
"default": 0,
"description": "Total peak thermal dissipation in BTU/hr (1W = 3.41214 BTU/hr)."
},
"center_of_gravity_y_mm": {
"type": "number",
"description": "Vertical Center of Gravity height from bottom of U1 in millimeters."
},
"available_portal_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
"description": "1-indexed U slots that allow front-to-rear cable pass-through (open U or brush panel)."
}
},
"description": "Aggregated mechanical mass, center of gravity, thermal BTU/hr, and acoustic dB(A) metrics.",
"additionalProperties": false
}
},
"description": "Updated 5-stage validation report after cable removal.",
"additionalProperties": false
},
"removed_cable_ids": {
"type": "array",
"items": {
"type": "string"
},
"description": "List of cable_id values that were disconnected."
},
"remaining_cables_count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Total number of cables remaining in the active rack project."
}
},
"description": "Cable disconnection result payload.",
"additionalProperties": {}
},
"issues": {
"type": "array",
"items": {
"type": "object",
"required": [
"code",
"severity",
"affected_instances",
"message",
"remediation_suggestions"
],
"properties": {
"code": {
"enum": [
"CHASSIS_COLLISION",
"PLUG_CLEARANCE_COLLISION",
"FRONT_DOOR_COLLISION",
"SLOT_DIMENSION_OVERFLOW",
"SLOT_INCOMPATIBLE",
"OUT_OF_RACK_BOUNDS",
"BLUEPRINT_NOT_FOUND",
"PORT_NOT_FOUND",
"PORT_ALREADY_OCCUPIED",
"CONNECTOR_INCOMPATIBLE",
"SIGNAL_PROTOCOL_INCOMPATIBLE",
"SPEED_MISMATCH",
"POE_BUDGET_EXCEEDED",
"POE_CLASS_EXCEEDED",
"UPS_OVERLOAD",
"UNPOWERED_DEVICE",
"TOP_HEAVY_RACK",
"NO_FRONT_TO_REAR_PORTAL",
"THERMAL_AIRFLOW_CONFLICT",
"THERMAL_HOTSPOT_STACKING",
"ACOUSTIC_NOISE_HIGH"
],
"type": "string",
"description": "Machine-readable deterministic validation diagnostic code."
},
"stage": {
"type": "integer",
"maximum": 5,
"minimum": 1,
"description": "Validation pipeline stage (1..5) that produced this finding."
},
"message": {
"type": "string",
"description": "Detailed engineering explanation with exact millimeter/watt figures."
},
"u_range": {
"type": "array",
"items": [
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
}
],
"maxItems": 2,
"minItems": 2,
"description": "Inclusive [start_u, end_u] range where the issue occurs.",
"additionalItems": false
},
"severity": {
"enum": [
"ERROR",
"WARNING",
"INFO"
],
"type": "string",
"description": "Severity level of the engineering constraint diagnostic."
},
"affected_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Device instance IDs involved in this diagnostic issue."
},
"remediation_actions": {
"type": "array",
"items": {
"type": "object",
"required": [
"action_type",
"description"
],
"properties": {
"action_type": {
"enum": [
"move_device",
"change_cable_type",
"connect_power",
"disconnect_cable",
"redistribute_poe",
"add_portal_gap",
"change_rack_depth"
],
"type": "string",
"description": "Recommended self-correction operation category."
},
"description": {
"type": "string",
"description": "Human- and agent-readable explanation of the remediation step."
},
"suggested_face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"target_cable_id": {
"type": "string",
"description": "Cable connection cable_id targeted by this remediation action."
},
"target_instance_id": {
"type": "string",
"description": "Device instance_id targeted by this remediation action."
},
"suggested_cable_type": {
"type": "string",
"description": "Suggested replacement cable_type (e.g. angled plug or higher speed grade)."
},
"suggested_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"exclusiveMinimum": 0
},
"description": "Candidate 1-indexed U positions that resolve the spatial conflict."
}
},
"description": "Structured self-correction action for autonomous agent remediation.",
"additionalProperties": false
},
"description": "Optional machine-actionable remediation descriptors."
},
"remediation_suggestions": {
"type": "array",
"items": {
"type": "string"
},
"minItems": 1,
"description": "Actionable self-correction instructions for the calling LLM agent."
}
},
"description": "Single validation finding with deterministic self-correction feedback.",
"additionalProperties": false
},
"description": "Structured diagnostic findings (ERROR, WARNING, INFO) with actionable remediation_suggestions."
},
"status": {
"enum": [
"VALID",
"INVALID"
],
"type": "string",
"description": "Deterministic execution outcome: \"VALID\" when the operation succeeded with 0 validation errors; \"INVALID\" when precondition or engineering validation errors are present in issues[]."
},
"summary": {
"type": "string",
"description": "Concise human- and agent-readable summary of the tool result and validation status."
}
},
"additionalProperties": false
},
"annotations": {
"title": "Disconnect Cables by ID or Device Instance",
"readOnlyHint": false,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": true
}
}Terminate external building or room cable drops onto the rear RJ45 ports of a mounted patch panel without consuming rack U slots, and optionally auto-create labeled Cat6A front patch cables to a mounted switch. 'groups[]' batch-generates drops first—with 'custom_labels[]' overriding numbered 'label_prefix' entries per index—followed by 'endpoints[]', allocating sequential free rear ports from 'start_port_number' and sequential free switch RJ45 ports from 'auto_connect_switch_start_port'. Setting 'clear_existing' destructively removes prior external drops on 'patch_panel_instance_id' and their front patch cables before allocation, while unmounted patch-panel or switch IDs return status 'INVALID' without mutating state. Use for off-rack building wiring entering the enclosure; never mount room endpoints via mount_equipment, and use connect_cables for purely internal rack-to-rack links.
| Parameter | Type | Description |
|---|---|---|
| groups | array | Batch groups of external drops (e.g., 10x PoE cameras, 5x Wi-Fi APs, 5x room LAN outlets). |
| endpoints | array | Individual external building/room drops to terminate on the rear of the patch panel. |
| clear_existing | boolean | If true, destructively clears existing external_endpoints (and their front patch cables) on patch_panel_instance_id before planning. |
| entry_position | string | Rear building cable conduit entry point into the rack frame. |
| start_port_number | integer | 1-indexed starting port number on the patch panel (defaults to next free rear port or 1). |
| patch_panel_instance_id * | string | Mounted patch panel instance_id whose rear ports receive the incoming building cable drops. |
| auto_connect_switch_start_port | integer | 1-indexed starting Ethernet port number on auto_connect_switch_instance_id (e.g., 1 for eth1). |
| auto_connect_switch_instance_id | string | Optional switch instance_id to automatically patch from the front of the patch panel using labeled Cat6A cables. |
{
"name": "plan_external_endpoints",
"title": "Terminate External Building Cable Drops on Patch Panel",
"description": "Terminate external building or room cable drops onto the rear RJ45 ports of a mounted patch panel without consuming rack U slots, and optionally auto-create labeled Cat6A front patch cables to a mounted switch. 'groups[]' batch-generates drops first—with 'custom_labels[]' overriding numbered 'label_prefix' entries per index—followed by 'endpoints[]', allocating sequential free rear ports from 'start_port_number' and sequential free switch RJ45 ports from 'auto_connect_switch_start_port'. Setting 'clear_existing' destructively removes prior external drops on 'patch_panel_instance_id' and their front patch cables before allocation, while unmounted patch-panel or switch IDs return status 'INVALID' without mutating state. Use for off-rack building wiring entering the enclosure; never mount room endpoints via mount_equipment, and use connect_cables for purely internal rack-to-rack links.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"patch_panel_instance_id"
],
"properties": {
"groups": {
"type": "array",
"items": {
"type": "object",
"required": [
"label_prefix"
],
"properties": {
"count": {
"type": "integer",
"default": 1,
"maximum": 96,
"description": "Number of external cable drops in this group (1..96).",
"exclusiveMinimum": 0
},
"vlan_id": {
"type": "integer",
"maximum": 4094,
"minimum": 1,
"description": "Optional IEEE 802.1Q VLAN ID assigned to this group."
},
"category": {
"enum": [
"poe-camera",
"wifi-ap",
"wall-outlet-pc",
"projector-media",
"workstation-dock",
"iot-controller",
"isp-wan-uplink",
"other-lan"
],
"type": "string",
"default": "other-lan",
"description": "Physical category of an external building or room drop entering the rack from outside."
},
"color_hex": {
"type": "string",
"pattern": "^#[0-9A-Fa-f]{6}$",
"description": "Hex color code for this group of cables (defaults to category color if omitted)."
},
"id_prefix": {
"type": "string",
"maxLength": 64,
"minLength": 1,
"description": "Optional ID prefix for generated endpoints (e.g., \"cam\", \"ap\", \"room\")."
},
"label_prefix": {
"type": "string",
"maxLength": 160,
"minLength": 1,
"description": "Human-readable label prefix (e.g., \"Kamera\", \"WLAN Access Point\", \"Raum LAN\")."
},
"room_or_zone": {
"type": "string",
"maxLength": 160,
"description": "Building zone or room name (e.g., \"Außenbereich\", \"EG Wohnzimmer\", \"Wohnräume\")."
},
"custom_labels": {
"type": "array",
"items": {
"type": "string",
"maxLength": 200,
"minLength": 1
},
"maxItems": 96,
"description": "Optional per-item custom labels overriding numbered prefix (e.g., [\"Büro – PC\", \"Heimkino – Beamer\", \"Studio – Workstation\"])."
},
"poe_draw_watts": {
"type": "number",
"default": 0,
"maximum": 200,
"minimum": 0,
"description": "PoE power draw in watts per drop (0 for standard LAN; e.g., 9 for PoE camera, 18 for Wi-Fi AP)."
},
"required_speed": {
"enum": [
"100m",
"1gbe",
"2.5gbe",
"10gbe"
],
"type": "string",
"default": "1gbe",
"description": "Required Ethernet link speed for the external room/device drop."
}
}
},
"maxItems": 24,
"description": "Batch groups of external drops (e.g., 10x PoE cameras, 5x Wi-Fi APs, 5x room LAN outlets)."
},
"endpoints": {
"type": "array",
"items": {
"type": "object",
"required": [
"label"
],
"properties": {
"label": {
"type": "string",
"maxLength": 200,
"minLength": 1,
"description": "Human-readable label for this room/device drop (e.g., \"Kamera 1 – Einfahrt\")."
},
"notes": {
"type": "string",
"maxLength": 1000,
"description": "Optional installation notes."
},
"vlan_id": {
"type": "integer",
"maximum": 4094,
"minimum": 1,
"description": "Optional VLAN ID (1..4094)."
},
"category": {
"enum": [
"poe-camera",
"wifi-ap",
"wall-outlet-pc",
"projector-media",
"workstation-dock",
"iot-controller",
"isp-wan-uplink",
"other-lan"
],
"type": "string",
"default": "other-lan",
"description": "Physical category of an external building or room drop entering the rack from outside."
},
"color_hex": {
"type": "string",
"pattern": "^#[0-9A-Fa-f]{6}$",
"description": "Optional hex color code for this drop and its front patch cable."
},
"endpoint_id": {
"type": "string",
"maxLength": 100,
"minLength": 1,
"description": "Optional explicit endpoint_id (auto-generated if omitted)."
},
"room_or_zone": {
"type": "string",
"maxLength": 160,
"description": "Optional building zone or room name."
},
"poe_draw_watts": {
"type": "number",
"default": 0,
"maximum": 200,
"minimum": 0,
"description": "Required PoE power draw in watts (0 for non-PoE LAN)."
},
"required_speed": {
"enum": [
"100m",
"1gbe",
"2.5gbe",
"10gbe"
],
"type": "string",
"default": "1gbe",
"description": "Required Ethernet link speed for the external room/device drop."
},
"patch_panel_port_id": {
"type": "string",
"maxLength": 128,
"minLength": 1,
"description": "Optional explicit patch panel port_id (e.g., \"p1\"); auto-assigned sequentially if omitted."
}
}
},
"maxItems": 128,
"description": "Individual external building/room drops to terminate on the rear of the patch panel."
},
"clear_existing": {
"type": "boolean",
"default": false,
"description": "If true, destructively clears existing external_endpoints (and their front patch cables) on patch_panel_instance_id before planning."
},
"entry_position": {
"enum": [
"top-rear",
"bottom-rear"
],
"type": "string",
"default": "top-rear",
"description": "Rear building cable conduit entry point into the rack frame."
},
"start_port_number": {
"type": "integer",
"maximum": 256,
"description": "1-indexed starting port number on the patch panel (defaults to next free rear port or 1).",
"exclusiveMinimum": 0
},
"patch_panel_instance_id": {
"type": "string",
"maxLength": 100,
"minLength": 1,
"description": "Mounted patch panel instance_id whose rear ports receive the incoming building cable drops."
},
"auto_connect_switch_start_port": {
"type": "integer",
"default": 1,
"maximum": 256,
"description": "1-indexed starting Ethernet port number on auto_connect_switch_instance_id (e.g., 1 for eth1).",
"exclusiveMinimum": 0
},
"auto_connect_switch_instance_id": {
"type": "string",
"maxLength": 100,
"minLength": 1,
"description": "Optional switch instance_id to automatically patch from the front of the patch panel using labeled Cat6A cables."
}
}
},
"outputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"status",
"summary",
"data",
"issues"
],
"properties": {
"data": {
"type": "object",
"properties": {
"validation": {
"type": "object",
"required": [
"status",
"is_valid",
"error_count",
"warning_count",
"issues",
"power_summary",
"mechanical_summary"
],
"properties": {
"issues": {
"type": "array",
"items": {
"type": "object",
"required": [
"code",
"severity",
"affected_instances",
"message",
"remediation_suggestions"
],
"properties": {
"code": {
"enum": [
"CHASSIS_COLLISION",
"PLUG_CLEARANCE_COLLISION",
"FRONT_DOOR_COLLISION",
"SLOT_DIMENSION_OVERFLOW",
"SLOT_INCOMPATIBLE",
"OUT_OF_RACK_BOUNDS",
"BLUEPRINT_NOT_FOUND",
"PORT_NOT_FOUND",
"PORT_ALREADY_OCCUPIED",
"CONNECTOR_INCOMPATIBLE",
"SIGNAL_PROTOCOL_INCOMPATIBLE",
"SPEED_MISMATCH",
"POE_BUDGET_EXCEEDED",
"POE_CLASS_EXCEEDED",
"UPS_OVERLOAD",
"UNPOWERED_DEVICE",
"TOP_HEAVY_RACK",
"NO_FRONT_TO_REAR_PORTAL",
"THERMAL_AIRFLOW_CONFLICT",
"THERMAL_HOTSPOT_STACKING",
"ACOUSTIC_NOISE_HIGH"
],
"type": "string",
"description": "Machine-readable deterministic validation diagnostic code."
},
"stage": {
"type": "integer",
"maximum": 5,
"minimum": 1,
"description": "Validation pipeline stage (1..5) that produced this finding."
},
"message": {
"type": "string",
"description": "Detailed engineering explanation with exact millimeter/watt figures."
},
"u_range": {
"type": "array",
"items": [
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
}
],
"maxItems": 2,
"minItems": 2,
"description": "Inclusive [start_u, end_u] range where the issue occurs.",
"additionalItems": false
},
"severity": {
"enum": [
"ERROR",
"WARNING",
"INFO"
],
"type": "string",
"description": "Severity level of the engineering constraint diagnostic."
},
"affected_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Device instance IDs involved in this diagnostic issue."
},
"remediation_actions": {
"type": "array",
"items": {
"type": "object",
"required": [
"action_type",
"description"
],
"properties": {
"action_type": {
"enum": [
"move_device",
"change_cable_type",
"connect_power",
"disconnect_cable",
"redistribute_poe",
"add_portal_gap",
"change_rack_depth"
],
"type": "string",
"description": "Recommended self-correction operation category."
},
"description": {
"type": "string",
"description": "Human- and agent-readable explanation of the remediation step."
},
"suggested_face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"target_cable_id": {
"type": "string",
"description": "Cable connection cable_id targeted by this remediation action."
},
"target_instance_id": {
"type": "string",
"description": "Device instance_id targeted by this remediation action."
},
"suggested_cable_type": {
"type": "string",
"description": "Suggested replacement cable_type (e.g. angled plug or higher speed grade)."
},
"suggested_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"exclusiveMinimum": 0
},
"description": "Candidate 1-indexed U positions that resolve the spatial conflict."
}
},
"description": "Structured self-correction action for autonomous agent remediation.",
"additionalProperties": false
},
"description": "Optional machine-actionable remediation descriptors."
},
"remediation_suggestions": {
"type": "array",
"items": {
"type": "string"
},
"minItems": 1,
"description": "Actionable self-correction instructions for the calling LLM agent."
}
},
"description": "Single validation finding with deterministic self-correction feedback.",
"additionalProperties": false
},
"description": "List of all detected ERROR, WARNING, and INFO diagnostic issues."
},
"status": {
"enum": [
"VALID",
"INVALID"
],
"type": "string",
"description": "Overall rack validation state (\"VALID\" when error_count is 0)."
},
"is_valid": {
"type": "boolean",
"description": "True when zero ERROR-level diagnostic issues exist."
},
"error_count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Total number of blocking ERROR diagnostics."
},
"power_summary": {
"type": "object",
"required": [
"total_system_watts",
"total_poe_watts",
"pse_budgets",
"power_sources",
"unpowered_active_instances"
],
"properties": {
"pse_budgets": {
"type": "array",
"items": {
"type": "object",
"required": [
"pse_instance_id",
"poe_budget_watts",
"consumed_poe_watts",
"remaining_poe_watts",
"downstream_devices"
],
"properties": {
"pse_instance_id": {
"type": "string",
"description": "Instance ID of the PoE Power Sourcing Equipment (PSE) switch."
},
"poe_budget_watts": {
"type": "number",
"description": "Maximum rated PoE output power budget of the switch in watts."
},
"consumed_poe_watts": {
"type": "number",
"description": "Total PoE power drawn by connected Powered Devices (PDs) in watts."
},
"downstream_devices": {
"type": "array",
"items": {
"type": "string"
},
"description": "Instance or endpoint IDs of downstream PoE consumers powered by this switch."
},
"remaining_poe_watts": {
"type": "number",
"description": "Remaining available PoE power budget in watts (negative if overloaded)."
}
},
"description": "PoE budget utilization breakdown for a single PSE switch.",
"additionalProperties": false
},
"description": "Per-switch PoE budget utilization breakdown."
},
"power_sources": {
"type": "array",
"items": {
"type": "object",
"required": [
"source_instance_id",
"role",
"capacity_watts",
"total_load_watts",
"utilization_percent"
],
"properties": {
"role": {
"enum": [
"pdu",
"ups"
],
"type": "string",
"description": "Electrical source classification (\"pdu\" or \"ups\")."
},
"capacity_watts": {
"type": "number",
"description": "Maximum rated output capacity of the power source in watts."
},
"total_load_watts": {
"type": "number",
"description": "Cumulative downstream system and PoE load in watts."
},
"source_instance_id": {
"type": "string",
"description": "Instance ID of the upstream PDU or UPS unit."
},
"utilization_percent": {
"type": "number",
"description": "Percentage of rated watt capacity consumed (0..100+)."
}
},
"description": "Load and capacity summary for a mounted PDU or UPS unit.",
"additionalProperties": false
},
"description": "Per-PDU and per-UPS electrical load breakdown."
},
"total_poe_watts": {
"type": "number",
"description": "Total PoE power draw across all connected PoE devices and external drops in watts."
},
"total_system_watts": {
"type": "number",
"description": "Total peak system power draw across all mounted equipment in watts."
},
"unpowered_active_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Active device instance IDs missing a valid AC, DC, USB-C, or PoE power input."
}
},
"description": "Aggregated electrical and PoE DAG power analysis.",
"additionalProperties": false
},
"warning_count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Total number of non-blocking WARNING diagnostics."
},
"mechanical_summary": {
"type": "object",
"required": [
"total_weight_grams",
"center_of_gravity_y_mm",
"normalized_cog_y",
"available_portal_u_positions",
"total_thermal_btu_hr",
"combined_noise_db_a",
"airflow_profile"
],
"properties": {
"airflow_profile": {
"enum": [
"uniform-front-to-rear",
"uniform-passive",
"hybrid-active-passive",
"mixed-conflict"
],
"type": "string",
"default": "uniform-passive",
"description": "Rack-wide thermal airflow regime classification."
},
"normalized_cog_y": {
"type": "number",
"description": "Normalized vertical Center of Gravity ratio (0.0 = bottom, 1.0 = top; keep <= 0.50)."
},
"total_weight_grams": {
"type": "number",
"description": "Total mass of all mounted equipment in grams."
},
"combined_noise_db_a": {
"type": "number",
"default": 0,
"description": "Logarithmic sum of acoustic noise emissions in dB(A) across all mounted devices."
},
"total_thermal_btu_hr": {
"type": "number",
"default": 0,
"description": "Total peak thermal dissipation in BTU/hr (1W = 3.41214 BTU/hr)."
},
"center_of_gravity_y_mm": {
"type": "number",
"description": "Vertical Center of Gravity height from bottom of U1 in millimeters."
},
"available_portal_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
"description": "1-indexed U slots that allow front-to-rear cable pass-through (open U or brush panel)."
}
},
"description": "Aggregated mechanical mass, center of gravity, thermal BTU/hr, and acoustic dB(A) metrics.",
"additionalProperties": false
}
},
"description": "Updated 5-stage validation report including cumulative PoE load from external building drops.",
"additionalProperties": false
},
"patching_guide": {
"type": "array",
"items": {
"type": "object",
"required": [
"step_number",
"endpoint_id",
"label",
"room_or_zone",
"poe_draw_watts",
"rear_punchdown",
"front_patch_cable",
"color_hex"
],
"properties": {
"label": {
"type": "string",
"description": "Human-readable room or device drop label."
},
"color_hex": {
"type": "string",
"description": "Assigned cable hex color code."
},
"endpoint_id": {
"type": "string",
"description": "Unique external endpoint identifier."
},
"step_number": {
"type": "integer",
"maximum": 9007199254740991,
"description": "Sequential installation step number.",
"exclusiveMinimum": 0
},
"room_or_zone": {
"type": "string",
"description": "Building zone or room name."
},
"poe_draw_watts": {
"type": "number",
"minimum": 0,
"description": "PoE power draw in watts for this drop."
},
"rear_punchdown": {
"type": "string",
"description": "Rear patch panel port termination assignment."
},
"front_patch_cable": {
"type": "string",
"description": "Front patch panel to switch port assignment."
}
},
"additionalProperties": {}
},
"description": "Step-by-step rear punchdown and front switch patching schedule."
},
"added_endpoints_count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Number of external building/room cable drops terminated on the patch panel rear ports."
},
"patch_panel_instance_id": {
"type": "string",
"description": "Target patch_panel_instance_id echoed when a pre-check fails."
},
"total_external_endpoints": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Total external endpoints now configured in the rack project."
},
"auto_patched_cables_count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Number of front Cat6A patch cables automatically created to the target switch."
},
"auto_connect_switch_instance_id": {
"type": "string",
"description": "Target auto_connect_switch_instance_id echoed when a pre-check fails."
}
},
"description": "External endpoint planning and auto-patching payload.",
"additionalProperties": {}
},
"issues": {
"type": "array",
"items": {
"type": "object",
"required": [
"code",
"severity",
"affected_instances",
"message",
"remediation_suggestions"
],
"properties": {
"code": {
"enum": [
"CHASSIS_COLLISION",
"PLUG_CLEARANCE_COLLISION",
"FRONT_DOOR_COLLISION",
"SLOT_DIMENSION_OVERFLOW",
"SLOT_INCOMPATIBLE",
"OUT_OF_RACK_BOUNDS",
"BLUEPRINT_NOT_FOUND",
"PORT_NOT_FOUND",
"PORT_ALREADY_OCCUPIED",
"CONNECTOR_INCOMPATIBLE",
"SIGNAL_PROTOCOL_INCOMPATIBLE",
"SPEED_MISMATCH",
"POE_BUDGET_EXCEEDED",
"POE_CLASS_EXCEEDED",
"UPS_OVERLOAD",
"UNPOWERED_DEVICE",
"TOP_HEAVY_RACK",
"NO_FRONT_TO_REAR_PORTAL",
"THERMAL_AIRFLOW_CONFLICT",
"THERMAL_HOTSPOT_STACKING",
"ACOUSTIC_NOISE_HIGH"
],
"type": "string",
"description": "Machine-readable deterministic validation diagnostic code."
},
"stage": {
"type": "integer",
"maximum": 5,
"minimum": 1,
"description": "Validation pipeline stage (1..5) that produced this finding."
},
"message": {
"type": "string",
"description": "Detailed engineering explanation with exact millimeter/watt figures."
},
"u_range": {
"type": "array",
"items": [
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
}
],
"maxItems": 2,
"minItems": 2,
"description": "Inclusive [start_u, end_u] range where the issue occurs.",
"additionalItems": false
},
"severity": {
"enum": [
"ERROR",
"WARNING",
"INFO"
],
"type": "string",
"description": "Severity level of the engineering constraint diagnostic."
},
"affected_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Device instance IDs involved in this diagnostic issue."
},
"remediation_actions": {
"type": "array",
"items": {
"type": "object",
"required": [
"action_type",
"description"
],
"properties": {
"action_type": {
"enum": [
"move_device",
"change_cable_type",
"connect_power",
"disconnect_cable",
"redistribute_poe",
"add_portal_gap",
"change_rack_depth"
],
"type": "string",
"description": "Recommended self-correction operation category."
},
"description": {
"type": "string",
"description": "Human- and agent-readable explanation of the remediation step."
},
"suggested_face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"target_cable_id": {
"type": "string",
"description": "Cable connection cable_id targeted by this remediation action."
},
"target_instance_id": {
"type": "string",
"description": "Device instance_id targeted by this remediation action."
},
"suggested_cable_type": {
"type": "string",
"description": "Suggested replacement cable_type (e.g. angled plug or higher speed grade)."
},
"suggested_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"exclusiveMinimum": 0
},
"description": "Candidate 1-indexed U positions that resolve the spatial conflict."
}
},
"description": "Structured self-correction action for autonomous agent remediation.",
"additionalProperties": false
},
"description": "Optional machine-actionable remediation descriptors."
},
"remediation_suggestions": {
"type": "array",
"items": {
"type": "string"
},
"minItems": 1,
"description": "Actionable self-correction instructions for the calling LLM agent."
}
},
"description": "Single validation finding with deterministic self-correction feedback.",
"additionalProperties": false
},
"description": "Structured diagnostic findings (ERROR, WARNING, INFO) with actionable remediation_suggestions."
},
"status": {
"enum": [
"VALID",
"INVALID"
],
"type": "string",
"description": "Deterministic execution outcome: \"VALID\" when the operation succeeded with 0 validation errors; \"INVALID\" when precondition or engineering validation errors are present in issues[]."
},
"summary": {
"type": "string",
"description": "Concise human- and agent-readable summary of the tool result and validation status."
}
},
"additionalProperties": false
},
"annotations": {
"title": "Terminate External Building Cable Drops on Patch Panel",
"readOnlyHint": false,
"openWorldHint": false,
"idempotentHint": false,
"destructiveHint": true
}
}Inspect the active rack.yaml state and run all 5 deterministic validation stages covering mechanical bounds, 3D depth and plug clearances, PoE and power budgets, cable compatibility, and thermal limits. Takes no parameters, performs zero state or undo-stack mutations, and returns the ASCII front and rear elevation diagram, power utilization summary, and all diagnostic issues with remediation_suggestions. Sets status to 'INVALID' instead of throwing whenever any validation ERROR is present. Use to inspect currently mounted equipment or verify zero errors before exporting; use export_deliverables instead to generate SVG, BOM, GLB, or 3D-print files.
No parameters.
{
"name": "validate_rack",
"title": "Inspect and Validate Active Rack State",
"description": "Inspect the active rack.yaml state and run all 5 deterministic validation stages covering mechanical bounds, 3D depth and plug clearances, PoE and power budgets, cable compatibility, and thermal limits. Takes no parameters, performs zero state or undo-stack mutations, and returns the ASCII front and rear elevation diagram, power utilization summary, and all diagnostic issues with remediation_suggestions. Sets status to 'INVALID' instead of throwing whenever any validation ERROR is present. Use to inspect currently mounted equipment or verify zero errors before exporting; use export_deliverables instead to generate SVG, BOM, GLB, or 3D-print files.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"properties": {}
},
"outputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"status",
"summary",
"data",
"issues"
],
"properties": {
"data": {
"type": "object",
"required": [
"is_valid",
"ascii_elevation",
"validation"
],
"properties": {
"is_valid": {
"type": "boolean",
"description": "True when error_count is 0 across all 5 validation stages."
},
"validation": {
"type": "object",
"required": [
"status",
"is_valid",
"error_count",
"warning_count",
"issues",
"power_summary",
"mechanical_summary"
],
"properties": {
"issues": {
"type": "array",
"items": {
"type": "object",
"required": [
"code",
"severity",
"affected_instances",
"message",
"remediation_suggestions"
],
"properties": {
"code": {
"enum": [
"CHASSIS_COLLISION",
"PLUG_CLEARANCE_COLLISION",
"FRONT_DOOR_COLLISION",
"SLOT_DIMENSION_OVERFLOW",
"SLOT_INCOMPATIBLE",
"OUT_OF_RACK_BOUNDS",
"BLUEPRINT_NOT_FOUND",
"PORT_NOT_FOUND",
"PORT_ALREADY_OCCUPIED",
"CONNECTOR_INCOMPATIBLE",
"SIGNAL_PROTOCOL_INCOMPATIBLE",
"SPEED_MISMATCH",
"POE_BUDGET_EXCEEDED",
"POE_CLASS_EXCEEDED",
"UPS_OVERLOAD",
"UNPOWERED_DEVICE",
"TOP_HEAVY_RACK",
"NO_FRONT_TO_REAR_PORTAL",
"THERMAL_AIRFLOW_CONFLICT",
"THERMAL_HOTSPOT_STACKING",
"ACOUSTIC_NOISE_HIGH"
],
"type": "string",
"description": "Machine-readable deterministic validation diagnostic code."
},
"stage": {
"type": "integer",
"maximum": 5,
"minimum": 1,
"description": "Validation pipeline stage (1..5) that produced this finding."
},
"message": {
"type": "string",
"description": "Detailed engineering explanation with exact millimeter/watt figures."
},
"u_range": {
"type": "array",
"items": [
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
}
],
"maxItems": 2,
"minItems": 2,
"description": "Inclusive [start_u, end_u] range where the issue occurs.",
"additionalItems": false
},
"severity": {
"enum": [
"ERROR",
"WARNING",
"INFO"
],
"type": "string",
"description": "Severity level of the engineering constraint diagnostic."
},
"affected_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Device instance IDs involved in this diagnostic issue."
},
"remediation_actions": {
"type": "array",
"items": {
"type": "object",
"required": [
"action_type",
"description"
],
"properties": {
"action_type": {
"enum": [
"move_device",
"change_cable_type",
"connect_power",
"disconnect_cable",
"redistribute_poe",
"add_portal_gap",
"change_rack_depth"
],
"type": "string",
"description": "Recommended self-correction operation category."
},
"description": {
"type": "string",
"description": "Human- and agent-readable explanation of the remediation step."
},
"suggested_face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"target_cable_id": {
"type": "string",
"description": "Cable connection cable_id targeted by this remediation action."
},
"target_instance_id": {
"type": "string",
"description": "Device instance_id targeted by this remediation action."
},
"suggested_cable_type": {
"type": "string",
"description": "Suggested replacement cable_type (e.g. angled plug or higher speed grade)."
},
"suggested_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"exclusiveMinimum": 0
},
"description": "Candidate 1-indexed U positions that resolve the spatial conflict."
}
},
"description": "Structured self-correction action for autonomous agent remediation.",
"additionalProperties": false
},
"description": "Optional machine-actionable remediation descriptors."
},
"remediation_suggestions": {
"type": "array",
"items": {
"type": "string"
},
"minItems": 1,
"description": "Actionable self-correction instructions for the calling LLM agent."
}
},
"description": "Single validation finding with deterministic self-correction feedback.",
"additionalProperties": false
},
"description": "List of all detected ERROR, WARNING, and INFO diagnostic issues."
},
"status": {
"enum": [
"VALID",
"INVALID"
],
"type": "string",
"description": "Overall rack validation state (\"VALID\" when error_count is 0)."
},
"is_valid": {
"type": "boolean",
"description": "True when zero ERROR-level diagnostic issues exist."
},
"error_count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Total number of blocking ERROR diagnostics."
},
"power_summary": {
"type": "object",
"required": [
"total_system_watts",
"total_poe_watts",
"pse_budgets",
"power_sources",
"unpowered_active_instances"
],
"properties": {
"pse_budgets": {
"type": "array",
"items": {
"type": "object",
"required": [
"pse_instance_id",
"poe_budget_watts",
"consumed_poe_watts",
"remaining_poe_watts",
"downstream_devices"
],
"properties": {
"pse_instance_id": {
"type": "string",
"description": "Instance ID of the PoE Power Sourcing Equipment (PSE) switch."
},
"poe_budget_watts": {
"type": "number",
"description": "Maximum rated PoE output power budget of the switch in watts."
},
"consumed_poe_watts": {
"type": "number",
"description": "Total PoE power drawn by connected Powered Devices (PDs) in watts."
},
"downstream_devices": {
"type": "array",
"items": {
"type": "string"
},
"description": "Instance or endpoint IDs of downstream PoE consumers powered by this switch."
},
"remaining_poe_watts": {
"type": "number",
"description": "Remaining available PoE power budget in watts (negative if overloaded)."
}
},
"description": "PoE budget utilization breakdown for a single PSE switch.",
"additionalProperties": false
},
"description": "Per-switch PoE budget utilization breakdown."
},
"power_sources": {
"type": "array",
"items": {
"type": "object",
"required": [
"source_instance_id",
"role",
"capacity_watts",
"total_load_watts",
"utilization_percent"
],
"properties": {
"role": {
"enum": [
"pdu",
"ups"
],
"type": "string",
"description": "Electrical source classification (\"pdu\" or \"ups\")."
},
"capacity_watts": {
"type": "number",
"description": "Maximum rated output capacity of the power source in watts."
},
"total_load_watts": {
"type": "number",
"description": "Cumulative downstream system and PoE load in watts."
},
"source_instance_id": {
"type": "string",
"description": "Instance ID of the upstream PDU or UPS unit."
},
"utilization_percent": {
"type": "number",
"description": "Percentage of rated watt capacity consumed (0..100+)."
}
},
"description": "Load and capacity summary for a mounted PDU or UPS unit.",
"additionalProperties": false
},
"description": "Per-PDU and per-UPS electrical load breakdown."
},
"total_poe_watts": {
"type": "number",
"description": "Total PoE power draw across all connected PoE devices and external drops in watts."
},
"total_system_watts": {
"type": "number",
"description": "Total peak system power draw across all mounted equipment in watts."
},
"unpowered_active_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Active device instance IDs missing a valid AC, DC, USB-C, or PoE power input."
}
},
"description": "Aggregated electrical and PoE DAG power analysis.",
"additionalProperties": false
},
"warning_count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Total number of non-blocking WARNING diagnostics."
},
"mechanical_summary": {
"type": "object",
"required": [
"total_weight_grams",
"center_of_gravity_y_mm",
"normalized_cog_y",
"available_portal_u_positions",
"total_thermal_btu_hr",
"combined_noise_db_a",
"airflow_profile"
],
"properties": {
"airflow_profile": {
"enum": [
"uniform-front-to-rear",
"uniform-passive",
"hybrid-active-passive",
"mixed-conflict"
],
"type": "string",
"default": "uniform-passive",
"description": "Rack-wide thermal airflow regime classification."
},
"normalized_cog_y": {
"type": "number",
"description": "Normalized vertical Center of Gravity ratio (0.0 = bottom, 1.0 = top; keep <= 0.50)."
},
"total_weight_grams": {
"type": "number",
"description": "Total mass of all mounted equipment in grams."
},
"combined_noise_db_a": {
"type": "number",
"default": 0,
"description": "Logarithmic sum of acoustic noise emissions in dB(A) across all mounted devices."
},
"total_thermal_btu_hr": {
"type": "number",
"default": 0,
"description": "Total peak thermal dissipation in BTU/hr (1W = 3.41214 BTU/hr)."
},
"center_of_gravity_y_mm": {
"type": "number",
"description": "Vertical Center of Gravity height from bottom of U1 in millimeters."
},
"available_portal_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
"description": "1-indexed U slots that allow front-to-rear cable pass-through (open U or brush panel)."
}
},
"description": "Aggregated mechanical mass, center of gravity, thermal BTU/hr, and acoustic dB(A) metrics.",
"additionalProperties": false
}
},
"description": "Complete 5-stage deterministic validation report with issues and remediation_suggestions.",
"additionalProperties": false
},
"ascii_elevation": {
"type": "string",
"description": "Formatted ASCII front/rear rack elevation diagram, mounted device inventory, and power/PoE summary."
}
},
"description": "Rack state inspection and validation result payload.",
"additionalProperties": {}
},
"issues": {
"type": "array",
"items": {
"type": "object",
"required": [
"code",
"severity",
"affected_instances",
"message",
"remediation_suggestions"
],
"properties": {
"code": {
"enum": [
"CHASSIS_COLLISION",
"PLUG_CLEARANCE_COLLISION",
"FRONT_DOOR_COLLISION",
"SLOT_DIMENSION_OVERFLOW",
"SLOT_INCOMPATIBLE",
"OUT_OF_RACK_BOUNDS",
"BLUEPRINT_NOT_FOUND",
"PORT_NOT_FOUND",
"PORT_ALREADY_OCCUPIED",
"CONNECTOR_INCOMPATIBLE",
"SIGNAL_PROTOCOL_INCOMPATIBLE",
"SPEED_MISMATCH",
"POE_BUDGET_EXCEEDED",
"POE_CLASS_EXCEEDED",
"UPS_OVERLOAD",
"UNPOWERED_DEVICE",
"TOP_HEAVY_RACK",
"NO_FRONT_TO_REAR_PORTAL",
"THERMAL_AIRFLOW_CONFLICT",
"THERMAL_HOTSPOT_STACKING",
"ACOUSTIC_NOISE_HIGH"
],
"type": "string",
"description": "Machine-readable deterministic validation diagnostic code."
},
"stage": {
"type": "integer",
"maximum": 5,
"minimum": 1,
"description": "Validation pipeline stage (1..5) that produced this finding."
},
"message": {
"type": "string",
"description": "Detailed engineering explanation with exact millimeter/watt figures."
},
"u_range": {
"type": "array",
"items": [
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
}
],
"maxItems": 2,
"minItems": 2,
"description": "Inclusive [start_u, end_u] range where the issue occurs.",
"additionalItems": false
},
"severity": {
"enum": [
"ERROR",
"WARNING",
"INFO"
],
"type": "string",
"description": "Severity level of the engineering constraint diagnostic."
},
"affected_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Device instance IDs involved in this diagnostic issue."
},
"remediation_actions": {
"type": "array",
"items": {
"type": "object",
"required": [
"action_type",
"description"
],
"properties": {
"action_type": {
"enum": [
"move_device",
"change_cable_type",
"connect_power",
"disconnect_cable",
"redistribute_poe",
"add_portal_gap",
"change_rack_depth"
],
"type": "string",
"description": "Recommended self-correction operation category."
},
"description": {
"type": "string",
"description": "Human- and agent-readable explanation of the remediation step."
},
"suggested_face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"target_cable_id": {
"type": "string",
"description": "Cable connection cable_id targeted by this remediation action."
},
"target_instance_id": {
"type": "string",
"description": "Device instance_id targeted by this remediation action."
},
"suggested_cable_type": {
"type": "string",
"description": "Suggested replacement cable_type (e.g. angled plug or higher speed grade)."
},
"suggested_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"exclusiveMinimum": 0
},
"description": "Candidate 1-indexed U positions that resolve the spatial conflict."
}
},
"description": "Structured self-correction action for autonomous agent remediation.",
"additionalProperties": false
},
"description": "Optional machine-actionable remediation descriptors."
},
"remediation_suggestions": {
"type": "array",
"items": {
"type": "string"
},
"minItems": 1,
"description": "Actionable self-correction instructions for the calling LLM agent."
}
},
"description": "Single validation finding with deterministic self-correction feedback.",
"additionalProperties": false
},
"description": "Structured diagnostic findings (ERROR, WARNING, INFO) with actionable remediation_suggestions."
},
"status": {
"enum": [
"VALID",
"INVALID"
],
"type": "string",
"description": "Deterministic execution outcome: \"VALID\" when the operation succeeded with 0 validation errors; \"INVALID\" when precondition or engineering validation errors are present in issues[]."
},
"summary": {
"type": "string",
"description": "Concise human- and agent-readable summary of the tool result and validation status."
}
},
"additionalProperties": false
},
"annotations": {
"title": "Inspect and Validate Active Rack State",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}
}Generate 2D elevation and wiring SVGs, a Markdown BOM, a binary 3D GLB scene, and parametric OpenSCAD or watertight STL 3D-print models for the active rack project. Omitting 'formats' exports all six types; 'carrier-scad' and 'carrier-stl' emit one file per mounted modular carrier, switch cradle, or printable cover panel and emit zero files when none are mounted, while 'output_dir' resolves relative paths within the project directory and creates missing folders. Local stdio execution writes deterministic filenames—elevation.svg, wiring-schematic.svg, BOM.md, rack-scene.glb, and <slug>.scad or <slug>.stl—overwriting same-named files in place, whereas hosted remote sessions stream in-memory HTTPS download URLs; neither mode mutates rack state or undo history. Use after validate_rack confirms a valid layout; use validate_rack instead for read-only validation and ASCII elevation inspection without generating export files.
| Parameter | Type | Description |
|---|---|---|
| formats | array | Deliverable formats to generate and write to disk (defaults to all 6 formats; carrier-scad and carrier-stl emit files when modular carriers are mounted). |
| output_dir | string | Optional target filesystem directory for generated files in local stdio mode (defaults to the directory of the active rack.yaml file; ignored on hosted remote MCP servers where HTTPS download URLs are returned instead). |
{
"name": "export_deliverables",
"title": "Export 2D SVG, BOM, 3D GLB, and 3D-Print Deliverables",
"description": "Generate 2D elevation and wiring SVGs, a Markdown BOM, a binary 3D GLB scene, and parametric OpenSCAD or watertight STL 3D-print models for the active rack project. Omitting 'formats' exports all six types; 'carrier-scad' and 'carrier-stl' emit one file per mounted modular carrier, switch cradle, or printable cover panel and emit zero files when none are mounted, while 'output_dir' resolves relative paths within the project directory and creates missing folders. Local stdio execution writes deterministic filenames—elevation.svg, wiring-schematic.svg, BOM.md, rack-scene.glb, and <slug>.scad or <slug>.stl—overwriting same-named files in place, whereas hosted remote sessions stream in-memory HTTPS download URLs; neither mode mutates rack state or undo history. Use after validate_rack confirms a valid layout; use validate_rack instead for read-only validation and ASCII elevation inspection without generating export files.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"properties": {
"formats": {
"type": "array",
"items": {
"enum": [
"elevation-svg",
"wiring-svg",
"bom-md",
"scene-glb",
"carrier-scad",
"carrier-stl"
],
"type": "string"
},
"default": [
"elevation-svg",
"wiring-svg",
"bom-md",
"scene-glb",
"carrier-scad",
"carrier-stl"
],
"maxItems": 6,
"description": "Deliverable formats to generate and write to disk (defaults to all 6 formats; carrier-scad and carrier-stl emit files when modular carriers are mounted)."
},
"output_dir": {
"type": "string",
"maxLength": 512,
"description": "Optional target filesystem directory for generated files in local stdio mode (defaults to the directory of the active rack.yaml file; ignored on hosted remote MCP servers where HTTPS download URLs are returned instead)."
}
}
},
"outputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"status",
"summary",
"data",
"issues"
],
"properties": {
"data": {
"type": "object",
"required": [
"output_dir",
"exported_files",
"bom_summary",
"validation"
],
"properties": {
"output_dir": {
"type": "string",
"description": "Resolved absolute directory path where deliverable files were written (or HTTPS base export endpoint when running on a hosted remote MCP server)."
},
"validation": {
"type": "object",
"required": [
"status",
"is_valid",
"error_count",
"warning_count",
"issues",
"power_summary",
"mechanical_summary"
],
"properties": {
"issues": {
"type": "array",
"items": {
"type": "object",
"required": [
"code",
"severity",
"affected_instances",
"message",
"remediation_suggestions"
],
"properties": {
"code": {
"enum": [
"CHASSIS_COLLISION",
"PLUG_CLEARANCE_COLLISION",
"FRONT_DOOR_COLLISION",
"SLOT_DIMENSION_OVERFLOW",
"SLOT_INCOMPATIBLE",
"OUT_OF_RACK_BOUNDS",
"BLUEPRINT_NOT_FOUND",
"PORT_NOT_FOUND",
"PORT_ALREADY_OCCUPIED",
"CONNECTOR_INCOMPATIBLE",
"SIGNAL_PROTOCOL_INCOMPATIBLE",
"SPEED_MISMATCH",
"POE_BUDGET_EXCEEDED",
"POE_CLASS_EXCEEDED",
"UPS_OVERLOAD",
"UNPOWERED_DEVICE",
"TOP_HEAVY_RACK",
"NO_FRONT_TO_REAR_PORTAL",
"THERMAL_AIRFLOW_CONFLICT",
"THERMAL_HOTSPOT_STACKING",
"ACOUSTIC_NOISE_HIGH"
],
"type": "string",
"description": "Machine-readable deterministic validation diagnostic code."
},
"stage": {
"type": "integer",
"maximum": 5,
"minimum": 1,
"description": "Validation pipeline stage (1..5) that produced this finding."
},
"message": {
"type": "string",
"description": "Detailed engineering explanation with exact millimeter/watt figures."
},
"u_range": {
"type": "array",
"items": [
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
}
],
"maxItems": 2,
"minItems": 2,
"description": "Inclusive [start_u, end_u] range where the issue occurs.",
"additionalItems": false
},
"severity": {
"enum": [
"ERROR",
"WARNING",
"INFO"
],
"type": "string",
"description": "Severity level of the engineering constraint diagnostic."
},
"affected_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Device instance IDs involved in this diagnostic issue."
},
"remediation_actions": {
"type": "array",
"items": {
"type": "object",
"required": [
"action_type",
"description"
],
"properties": {
"action_type": {
"enum": [
"move_device",
"change_cable_type",
"connect_power",
"disconnect_cable",
"redistribute_poe",
"add_portal_gap",
"change_rack_depth"
],
"type": "string",
"description": "Recommended self-correction operation category."
},
"description": {
"type": "string",
"description": "Human- and agent-readable explanation of the remediation step."
},
"suggested_face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"target_cable_id": {
"type": "string",
"description": "Cable connection cable_id targeted by this remediation action."
},
"target_instance_id": {
"type": "string",
"description": "Device instance_id targeted by this remediation action."
},
"suggested_cable_type": {
"type": "string",
"description": "Suggested replacement cable_type (e.g. angled plug or higher speed grade)."
},
"suggested_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"exclusiveMinimum": 0
},
"description": "Candidate 1-indexed U positions that resolve the spatial conflict."
}
},
"description": "Structured self-correction action for autonomous agent remediation.",
"additionalProperties": false
},
"description": "Optional machine-actionable remediation descriptors."
},
"remediation_suggestions": {
"type": "array",
"items": {
"type": "string"
},
"minItems": 1,
"description": "Actionable self-correction instructions for the calling LLM agent."
}
},
"description": "Single validation finding with deterministic self-correction feedback.",
"additionalProperties": false
},
"description": "List of all detected ERROR, WARNING, and INFO diagnostic issues."
},
"status": {
"enum": [
"VALID",
"INVALID"
],
"type": "string",
"description": "Overall rack validation state (\"VALID\" when error_count is 0)."
},
"is_valid": {
"type": "boolean",
"description": "True when zero ERROR-level diagnostic issues exist."
},
"error_count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Total number of blocking ERROR diagnostics."
},
"power_summary": {
"type": "object",
"required": [
"total_system_watts",
"total_poe_watts",
"pse_budgets",
"power_sources",
"unpowered_active_instances"
],
"properties": {
"pse_budgets": {
"type": "array",
"items": {
"type": "object",
"required": [
"pse_instance_id",
"poe_budget_watts",
"consumed_poe_watts",
"remaining_poe_watts",
"downstream_devices"
],
"properties": {
"pse_instance_id": {
"type": "string",
"description": "Instance ID of the PoE Power Sourcing Equipment (PSE) switch."
},
"poe_budget_watts": {
"type": "number",
"description": "Maximum rated PoE output power budget of the switch in watts."
},
"consumed_poe_watts": {
"type": "number",
"description": "Total PoE power drawn by connected Powered Devices (PDs) in watts."
},
"downstream_devices": {
"type": "array",
"items": {
"type": "string"
},
"description": "Instance or endpoint IDs of downstream PoE consumers powered by this switch."
},
"remaining_poe_watts": {
"type": "number",
"description": "Remaining available PoE power budget in watts (negative if overloaded)."
}
},
"description": "PoE budget utilization breakdown for a single PSE switch.",
"additionalProperties": false
},
"description": "Per-switch PoE budget utilization breakdown."
},
"power_sources": {
"type": "array",
"items": {
"type": "object",
"required": [
"source_instance_id",
"role",
"capacity_watts",
"total_load_watts",
"utilization_percent"
],
"properties": {
"role": {
"enum": [
"pdu",
"ups"
],
"type": "string",
"description": "Electrical source classification (\"pdu\" or \"ups\")."
},
"capacity_watts": {
"type": "number",
"description": "Maximum rated output capacity of the power source in watts."
},
"total_load_watts": {
"type": "number",
"description": "Cumulative downstream system and PoE load in watts."
},
"source_instance_id": {
"type": "string",
"description": "Instance ID of the upstream PDU or UPS unit."
},
"utilization_percent": {
"type": "number",
"description": "Percentage of rated watt capacity consumed (0..100+)."
}
},
"description": "Load and capacity summary for a mounted PDU or UPS unit.",
"additionalProperties": false
},
"description": "Per-PDU and per-UPS electrical load breakdown."
},
"total_poe_watts": {
"type": "number",
"description": "Total PoE power draw across all connected PoE devices and external drops in watts."
},
"total_system_watts": {
"type": "number",
"description": "Total peak system power draw across all mounted equipment in watts."
},
"unpowered_active_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Active device instance IDs missing a valid AC, DC, USB-C, or PoE power input."
}
},
"description": "Aggregated electrical and PoE DAG power analysis.",
"additionalProperties": false
},
"warning_count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Total number of non-blocking WARNING diagnostics."
},
"mechanical_summary": {
"type": "object",
"required": [
"total_weight_grams",
"center_of_gravity_y_mm",
"normalized_cog_y",
"available_portal_u_positions",
"total_thermal_btu_hr",
"combined_noise_db_a",
"airflow_profile"
],
"properties": {
"airflow_profile": {
"enum": [
"uniform-front-to-rear",
"uniform-passive",
"hybrid-active-passive",
"mixed-conflict"
],
"type": "string",
"default": "uniform-passive",
"description": "Rack-wide thermal airflow regime classification."
},
"normalized_cog_y": {
"type": "number",
"description": "Normalized vertical Center of Gravity ratio (0.0 = bottom, 1.0 = top; keep <= 0.50)."
},
"total_weight_grams": {
"type": "number",
"description": "Total mass of all mounted equipment in grams."
},
"combined_noise_db_a": {
"type": "number",
"default": 0,
"description": "Logarithmic sum of acoustic noise emissions in dB(A) across all mounted devices."
},
"total_thermal_btu_hr": {
"type": "number",
"default": 0,
"description": "Total peak thermal dissipation in BTU/hr (1W = 3.41214 BTU/hr)."
},
"center_of_gravity_y_mm": {
"type": "number",
"description": "Vertical Center of Gravity height from bottom of U1 in millimeters."
},
"available_portal_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
"description": "1-indexed U slots that allow front-to-rear cable pass-through (open U or brush panel)."
}
},
"description": "Aggregated mechanical mass, center of gravity, thermal BTU/hr, and acoustic dB(A) metrics.",
"additionalProperties": false
}
},
"description": "Current 5-stage validation report at the time of export.",
"additionalProperties": false
},
"bom_summary": {
"type": "object",
"required": [
"mounted_devices_count",
"cables_count",
"total_power_draw_watts",
"total_poe_draw_watts",
"total_poe_budget_watts"
],
"properties": {
"cables_count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Total routed cables."
},
"total_poe_draw_watts": {
"type": "number",
"minimum": 0,
"description": "Total PoE power draw in watts."
},
"mounted_devices_count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Total mounted rack devices and carrier sub-modules."
},
"total_poe_budget_watts": {
"type": "number",
"minimum": 0,
"description": "Total available PSE PoE budget in watts."
},
"total_power_draw_watts": {
"type": "number",
"minimum": 0,
"description": "Total peak system power draw in watts."
}
},
"description": "Summary counts and power totals included in the Bill of Materials.",
"additionalProperties": {}
},
"rack_yaml_url": {
"type": "string",
"description": "Direct HTTPS download URL for the session rack.yaml source of truth (present in hosted remote MCP mode)."
},
"exported_files": {
"type": "array",
"items": {
"type": "object",
"required": [
"format",
"path",
"size_bytes"
],
"properties": {
"path": {
"type": "string",
"description": "Absolute filesystem path of the written file (or direct HTTPS download URL in hosted remote MCP mode)."
},
"format": {
"type": "string",
"description": "Deliverable format identifier (e.g., \"elevation-svg\", \"carrier-stl\")."
},
"filename": {
"type": "string",
"description": "Suggested local filename for saving the deliverable."
},
"size_bytes": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Size of the generated deliverable in bytes."
},
"download_url": {
"type": "string",
"description": "Direct HTTPS download URL for this deliverable when connected to a hosted remote MCP server."
}
},
"additionalProperties": {}
},
"description": "Metadata for each generated deliverable file or download URL."
},
"live_viewer_url": {
"type": "string",
"description": "Interactive 3D/2D Web-Viewer URL bound live to this remote MCP session (present in hosted remote MCP mode)."
}
},
"description": "Deliverable export result payload.",
"additionalProperties": {}
},
"issues": {
"type": "array",
"items": {
"type": "object",
"required": [
"code",
"severity",
"affected_instances",
"message",
"remediation_suggestions"
],
"properties": {
"code": {
"enum": [
"CHASSIS_COLLISION",
"PLUG_CLEARANCE_COLLISION",
"FRONT_DOOR_COLLISION",
"SLOT_DIMENSION_OVERFLOW",
"SLOT_INCOMPATIBLE",
"OUT_OF_RACK_BOUNDS",
"BLUEPRINT_NOT_FOUND",
"PORT_NOT_FOUND",
"PORT_ALREADY_OCCUPIED",
"CONNECTOR_INCOMPATIBLE",
"SIGNAL_PROTOCOL_INCOMPATIBLE",
"SPEED_MISMATCH",
"POE_BUDGET_EXCEEDED",
"POE_CLASS_EXCEEDED",
"UPS_OVERLOAD",
"UNPOWERED_DEVICE",
"TOP_HEAVY_RACK",
"NO_FRONT_TO_REAR_PORTAL",
"THERMAL_AIRFLOW_CONFLICT",
"THERMAL_HOTSPOT_STACKING",
"ACOUSTIC_NOISE_HIGH"
],
"type": "string",
"description": "Machine-readable deterministic validation diagnostic code."
},
"stage": {
"type": "integer",
"maximum": 5,
"minimum": 1,
"description": "Validation pipeline stage (1..5) that produced this finding."
},
"message": {
"type": "string",
"description": "Detailed engineering explanation with exact millimeter/watt figures."
},
"u_range": {
"type": "array",
"items": [
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
}
],
"maxItems": 2,
"minItems": 2,
"description": "Inclusive [start_u, end_u] range where the issue occurs.",
"additionalItems": false
},
"severity": {
"enum": [
"ERROR",
"WARNING",
"INFO"
],
"type": "string",
"description": "Severity level of the engineering constraint diagnostic."
},
"affected_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Device instance IDs involved in this diagnostic issue."
},
"remediation_actions": {
"type": "array",
"items": {
"type": "object",
"required": [
"action_type",
"description"
],
"properties": {
"action_type": {
"enum": [
"move_device",
"change_cable_type",
"connect_power",
"disconnect_cable",
"redistribute_poe",
"add_portal_gap",
"change_rack_depth"
],
"type": "string",
"description": "Recommended self-correction operation category."
},
"description": {
"type": "string",
"description": "Human- and agent-readable explanation of the remediation step."
},
"suggested_face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"target_cable_id": {
"type": "string",
"description": "Cable connection cable_id targeted by this remediation action."
},
"target_instance_id": {
"type": "string",
"description": "Device instance_id targeted by this remediation action."
},
"suggested_cable_type": {
"type": "string",
"description": "Suggested replacement cable_type (e.g. angled plug or higher speed grade)."
},
"suggested_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"exclusiveMinimum": 0
},
"description": "Candidate 1-indexed U positions that resolve the spatial conflict."
}
},
"description": "Structured self-correction action for autonomous agent remediation.",
"additionalProperties": false
},
"description": "Optional machine-actionable remediation descriptors."
},
"remediation_suggestions": {
"type": "array",
"items": {
"type": "string"
},
"minItems": 1,
"description": "Actionable self-correction instructions for the calling LLM agent."
}
},
"description": "Single validation finding with deterministic self-correction feedback.",
"additionalProperties": false
},
"description": "Structured diagnostic findings (ERROR, WARNING, INFO) with actionable remediation_suggestions."
},
"status": {
"enum": [
"VALID",
"INVALID"
],
"type": "string",
"description": "Deterministic execution outcome: \"VALID\" when the operation succeeded with 0 validation errors; \"INVALID\" when precondition or engineering validation errors are present in issues[]."
},
"summary": {
"type": "string",
"description": "Concise human- and agent-readable summary of the tool result and validation status."
}
},
"additionalProperties": false
},
"annotations": {
"title": "Export 2D SVG, BOM, 3D GLB, and 3D-Print Deliverables",
"readOnlyHint": false,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": true
}
}Traverse the per-project in-memory history ring buffer of up to 50 snapshots to revert the latest rack mutation or reapply a reverted mutation, updating rack.yaml atomically. Setting 'action' to 'undo' steps backward across rack-state mutations—excluding catalog-only define_custom_blueprint calls and read-only tools—and pushes the displaced state onto the redo stack, whereas 'redo' is available only immediately after 'undo' because any new rack mutation flushes the redo stack. Calling either action when its target stack is empty is a safe no-op returning applied=false without throwing. Use to roll back an unintended batch change or accidental init_rack reset; use modify_equipment or disconnect_cables instead to edit specific items without reverting intermediate steps.
| Parameter | Type | Description |
|---|---|---|
| action * | string | History traversal direction: "undo" reverts the most recent state mutation, "redo" reapplies a reverted mutation. |
{
"name": "undo_redo",
"title": "Undo or Redo Rack State Mutation",
"description": "Traverse the per-project in-memory history ring buffer of up to 50 snapshots to revert the latest rack mutation or reapply a reverted mutation, updating rack.yaml atomically. Setting 'action' to 'undo' steps backward across rack-state mutations—excluding catalog-only define_custom_blueprint calls and read-only tools—and pushes the displaced state onto the redo stack, whereas 'redo' is available only immediately after 'undo' because any new rack mutation flushes the redo stack. Calling either action when its target stack is empty is a safe no-op returning applied=false without throwing. Use to roll back an unintended batch change or accidental init_rack reset; use modify_equipment or disconnect_cables instead to edit specific items without reverting intermediate steps.",
"inputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"action"
],
"properties": {
"action": {
"enum": [
"undo",
"redo"
],
"type": "string",
"description": "History traversal direction: \"undo\" reverts the most recent state mutation, \"redo\" reapplies a reverted mutation."
}
}
},
"outputSchema": {
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"status",
"summary",
"data",
"issues"
],
"properties": {
"data": {
"type": "object",
"required": [
"action",
"applied",
"undo_available",
"redo_available",
"ascii_elevation",
"validation"
],
"properties": {
"action": {
"enum": [
"undo",
"redo"
],
"type": "string",
"description": "History traversal direction that was requested."
},
"applied": {
"type": "boolean",
"description": "True if a history snapshot was restored; false if the target history stack was empty."
},
"validation": {
"type": "object",
"required": [
"status",
"is_valid",
"error_count",
"warning_count",
"issues",
"power_summary",
"mechanical_summary"
],
"properties": {
"issues": {
"type": "array",
"items": {
"type": "object",
"required": [
"code",
"severity",
"affected_instances",
"message",
"remediation_suggestions"
],
"properties": {
"code": {
"enum": [
"CHASSIS_COLLISION",
"PLUG_CLEARANCE_COLLISION",
"FRONT_DOOR_COLLISION",
"SLOT_DIMENSION_OVERFLOW",
"SLOT_INCOMPATIBLE",
"OUT_OF_RACK_BOUNDS",
"BLUEPRINT_NOT_FOUND",
"PORT_NOT_FOUND",
"PORT_ALREADY_OCCUPIED",
"CONNECTOR_INCOMPATIBLE",
"SIGNAL_PROTOCOL_INCOMPATIBLE",
"SPEED_MISMATCH",
"POE_BUDGET_EXCEEDED",
"POE_CLASS_EXCEEDED",
"UPS_OVERLOAD",
"UNPOWERED_DEVICE",
"TOP_HEAVY_RACK",
"NO_FRONT_TO_REAR_PORTAL",
"THERMAL_AIRFLOW_CONFLICT",
"THERMAL_HOTSPOT_STACKING",
"ACOUSTIC_NOISE_HIGH"
],
"type": "string",
"description": "Machine-readable deterministic validation diagnostic code."
},
"stage": {
"type": "integer",
"maximum": 5,
"minimum": 1,
"description": "Validation pipeline stage (1..5) that produced this finding."
},
"message": {
"type": "string",
"description": "Detailed engineering explanation with exact millimeter/watt figures."
},
"u_range": {
"type": "array",
"items": [
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
}
],
"maxItems": 2,
"minItems": 2,
"description": "Inclusive [start_u, end_u] range where the issue occurs.",
"additionalItems": false
},
"severity": {
"enum": [
"ERROR",
"WARNING",
"INFO"
],
"type": "string",
"description": "Severity level of the engineering constraint diagnostic."
},
"affected_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Device instance IDs involved in this diagnostic issue."
},
"remediation_actions": {
"type": "array",
"items": {
"type": "object",
"required": [
"action_type",
"description"
],
"properties": {
"action_type": {
"enum": [
"move_device",
"change_cable_type",
"connect_power",
"disconnect_cable",
"redistribute_poe",
"add_portal_gap",
"change_rack_depth"
],
"type": "string",
"description": "Recommended self-correction operation category."
},
"description": {
"type": "string",
"description": "Human- and agent-readable explanation of the remediation step."
},
"suggested_face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"target_cable_id": {
"type": "string",
"description": "Cable connection cable_id targeted by this remediation action."
},
"target_instance_id": {
"type": "string",
"description": "Device instance_id targeted by this remediation action."
},
"suggested_cable_type": {
"type": "string",
"description": "Suggested replacement cable_type (e.g. angled plug or higher speed grade)."
},
"suggested_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"exclusiveMinimum": 0
},
"description": "Candidate 1-indexed U positions that resolve the spatial conflict."
}
},
"description": "Structured self-correction action for autonomous agent remediation.",
"additionalProperties": false
},
"description": "Optional machine-actionable remediation descriptors."
},
"remediation_suggestions": {
"type": "array",
"items": {
"type": "string"
},
"minItems": 1,
"description": "Actionable self-correction instructions for the calling LLM agent."
}
},
"description": "Single validation finding with deterministic self-correction feedback.",
"additionalProperties": false
},
"description": "List of all detected ERROR, WARNING, and INFO diagnostic issues."
},
"status": {
"enum": [
"VALID",
"INVALID"
],
"type": "string",
"description": "Overall rack validation state (\"VALID\" when error_count is 0)."
},
"is_valid": {
"type": "boolean",
"description": "True when zero ERROR-level diagnostic issues exist."
},
"error_count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Total number of blocking ERROR diagnostics."
},
"power_summary": {
"type": "object",
"required": [
"total_system_watts",
"total_poe_watts",
"pse_budgets",
"power_sources",
"unpowered_active_instances"
],
"properties": {
"pse_budgets": {
"type": "array",
"items": {
"type": "object",
"required": [
"pse_instance_id",
"poe_budget_watts",
"consumed_poe_watts",
"remaining_poe_watts",
"downstream_devices"
],
"properties": {
"pse_instance_id": {
"type": "string",
"description": "Instance ID of the PoE Power Sourcing Equipment (PSE) switch."
},
"poe_budget_watts": {
"type": "number",
"description": "Maximum rated PoE output power budget of the switch in watts."
},
"consumed_poe_watts": {
"type": "number",
"description": "Total PoE power drawn by connected Powered Devices (PDs) in watts."
},
"downstream_devices": {
"type": "array",
"items": {
"type": "string"
},
"description": "Instance or endpoint IDs of downstream PoE consumers powered by this switch."
},
"remaining_poe_watts": {
"type": "number",
"description": "Remaining available PoE power budget in watts (negative if overloaded)."
}
},
"description": "PoE budget utilization breakdown for a single PSE switch.",
"additionalProperties": false
},
"description": "Per-switch PoE budget utilization breakdown."
},
"power_sources": {
"type": "array",
"items": {
"type": "object",
"required": [
"source_instance_id",
"role",
"capacity_watts",
"total_load_watts",
"utilization_percent"
],
"properties": {
"role": {
"enum": [
"pdu",
"ups"
],
"type": "string",
"description": "Electrical source classification (\"pdu\" or \"ups\")."
},
"capacity_watts": {
"type": "number",
"description": "Maximum rated output capacity of the power source in watts."
},
"total_load_watts": {
"type": "number",
"description": "Cumulative downstream system and PoE load in watts."
},
"source_instance_id": {
"type": "string",
"description": "Instance ID of the upstream PDU or UPS unit."
},
"utilization_percent": {
"type": "number",
"description": "Percentage of rated watt capacity consumed (0..100+)."
}
},
"description": "Load and capacity summary for a mounted PDU or UPS unit.",
"additionalProperties": false
},
"description": "Per-PDU and per-UPS electrical load breakdown."
},
"total_poe_watts": {
"type": "number",
"description": "Total PoE power draw across all connected PoE devices and external drops in watts."
},
"total_system_watts": {
"type": "number",
"description": "Total peak system power draw across all mounted equipment in watts."
},
"unpowered_active_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Active device instance IDs missing a valid AC, DC, USB-C, or PoE power input."
}
},
"description": "Aggregated electrical and PoE DAG power analysis.",
"additionalProperties": false
},
"warning_count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Total number of non-blocking WARNING diagnostics."
},
"mechanical_summary": {
"type": "object",
"required": [
"total_weight_grams",
"center_of_gravity_y_mm",
"normalized_cog_y",
"available_portal_u_positions",
"total_thermal_btu_hr",
"combined_noise_db_a",
"airflow_profile"
],
"properties": {
"airflow_profile": {
"enum": [
"uniform-front-to-rear",
"uniform-passive",
"hybrid-active-passive",
"mixed-conflict"
],
"type": "string",
"default": "uniform-passive",
"description": "Rack-wide thermal airflow regime classification."
},
"normalized_cog_y": {
"type": "number",
"description": "Normalized vertical Center of Gravity ratio (0.0 = bottom, 1.0 = top; keep <= 0.50)."
},
"total_weight_grams": {
"type": "number",
"description": "Total mass of all mounted equipment in grams."
},
"combined_noise_db_a": {
"type": "number",
"default": 0,
"description": "Logarithmic sum of acoustic noise emissions in dB(A) across all mounted devices."
},
"total_thermal_btu_hr": {
"type": "number",
"default": 0,
"description": "Total peak thermal dissipation in BTU/hr (1W = 3.41214 BTU/hr)."
},
"center_of_gravity_y_mm": {
"type": "number",
"description": "Vertical Center of Gravity height from bottom of U1 in millimeters."
},
"available_portal_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
"description": "1-indexed U slots that allow front-to-rear cable pass-through (open U or brush panel)."
}
},
"description": "Aggregated mechanical mass, center of gravity, thermal BTU/hr, and acoustic dB(A) metrics.",
"additionalProperties": false
}
},
"description": "Updated 5-stage validation report for the restored rack state.",
"additionalProperties": false
},
"redo_available": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Number of remaining redo snapshots available in memory."
},
"undo_available": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Number of remaining undo snapshots available in memory."
},
"ascii_elevation": {
"type": "string",
"description": "Updated ASCII front/rear rack elevation diagram after history traversal."
}
},
"description": "Undo/redo history traversal result payload.",
"additionalProperties": {}
},
"issues": {
"type": "array",
"items": {
"type": "object",
"required": [
"code",
"severity",
"affected_instances",
"message",
"remediation_suggestions"
],
"properties": {
"code": {
"enum": [
"CHASSIS_COLLISION",
"PLUG_CLEARANCE_COLLISION",
"FRONT_DOOR_COLLISION",
"SLOT_DIMENSION_OVERFLOW",
"SLOT_INCOMPATIBLE",
"OUT_OF_RACK_BOUNDS",
"BLUEPRINT_NOT_FOUND",
"PORT_NOT_FOUND",
"PORT_ALREADY_OCCUPIED",
"CONNECTOR_INCOMPATIBLE",
"SIGNAL_PROTOCOL_INCOMPATIBLE",
"SPEED_MISMATCH",
"POE_BUDGET_EXCEEDED",
"POE_CLASS_EXCEEDED",
"UPS_OVERLOAD",
"UNPOWERED_DEVICE",
"TOP_HEAVY_RACK",
"NO_FRONT_TO_REAR_PORTAL",
"THERMAL_AIRFLOW_CONFLICT",
"THERMAL_HOTSPOT_STACKING",
"ACOUSTIC_NOISE_HIGH"
],
"type": "string",
"description": "Machine-readable deterministic validation diagnostic code."
},
"stage": {
"type": "integer",
"maximum": 5,
"minimum": 1,
"description": "Validation pipeline stage (1..5) that produced this finding."
},
"message": {
"type": "string",
"description": "Detailed engineering explanation with exact millimeter/watt figures."
},
"u_range": {
"type": "array",
"items": [
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
},
{
"type": "integer",
"maximum": 9007199254740991,
"minimum": -9007199254740991
}
],
"maxItems": 2,
"minItems": 2,
"description": "Inclusive [start_u, end_u] range where the issue occurs.",
"additionalItems": false
},
"severity": {
"enum": [
"ERROR",
"WARNING",
"INFO"
],
"type": "string",
"description": "Severity level of the engineering constraint diagnostic."
},
"affected_instances": {
"type": "array",
"items": {
"type": "string"
},
"description": "Device instance IDs involved in this diagnostic issue."
},
"remediation_actions": {
"type": "array",
"items": {
"type": "object",
"required": [
"action_type",
"description"
],
"properties": {
"action_type": {
"enum": [
"move_device",
"change_cable_type",
"connect_power",
"disconnect_cable",
"redistribute_poe",
"add_portal_gap",
"change_rack_depth"
],
"type": "string",
"description": "Recommended self-correction operation category."
},
"description": {
"type": "string",
"description": "Human- and agent-readable explanation of the remediation step."
},
"suggested_face": {
"enum": [
"front",
"rear"
],
"type": "string",
"description": "Mounting or port face relative to the rack or chassis."
},
"target_cable_id": {
"type": "string",
"description": "Cable connection cable_id targeted by this remediation action."
},
"target_instance_id": {
"type": "string",
"description": "Device instance_id targeted by this remediation action."
},
"suggested_cable_type": {
"type": "string",
"description": "Suggested replacement cable_type (e.g. angled plug or higher speed grade)."
},
"suggested_u_positions": {
"type": "array",
"items": {
"type": "integer",
"maximum": 9007199254740991,
"exclusiveMinimum": 0
},
"description": "Candidate 1-indexed U positions that resolve the spatial conflict."
}
},
"description": "Structured self-correction action for autonomous agent remediation.",
"additionalProperties": false
},
"description": "Optional machine-actionable remediation descriptors."
},
"remediation_suggestions": {
"type": "array",
"items": {
"type": "string"
},
"minItems": 1,
"description": "Actionable self-correction instructions for the calling LLM agent."
}
},
"description": "Single validation finding with deterministic self-correction feedback.",
"additionalProperties": false
},
"description": "Structured diagnostic findings (ERROR, WARNING, INFO) with actionable remediation_suggestions."
},
"status": {
"enum": [
"VALID",
"INVALID"
],
"type": "string",
"description": "Deterministic execution outcome: \"VALID\" when the operation succeeded with 0 validation errors; \"INVALID\" when precondition or engineering validation errors are present in issues[]."
},
"summary": {
"type": "string",
"description": "Concise human- and agent-readable summary of the tool result and validation status."
}
},
"additionalProperties": false
},
"annotations": {
"title": "Undo or Redo Rack State Mutation",
"readOnlyHint": false,
"openWorldHint": false,
"idempotentHint": false,
"destructiveHint": false
}
}RackArchitect MCP (rack_architect_mcp) is a deterministic Rack-as-Code planning, 5-stage validation, and 2D/3D/STL CAD export server for 19-inch, 10-inch, and 6-inch racks. Never guess millimeter coordinates, depth collisions, or PoE budgets: use search_catalog and get_device_blueprint to discover hardware specs, init_rack to create a new empty enclosure (or validate_rack to inspect the current rack state), mount_equipment and modify_equipment to place or update devices (respecting explicit user hardware/U-slot requests 100%, or applying bottom-up UPS -> NAS/Compute -> Brush/Open-U Portal -> Gateway/Switch -> Top Patch Panel zoning for open requests), plan_external_endpoints for off-rack building cable drops, connect_cables and disconnect_cables for wiring, validate_rack to verify zero errors using remediation_suggestions, and export_deliverables to generate SVG, BOM, GLB, and 3D-printable OpenSCAD/STL files. When connected to a Hosted Remote MCP session, always share data.live_viewer_url and data.exported_files[].download_url (plus data.rack_yaml_url) directly with the user.
Names, descriptions and schemas were written by the server and are shown as data.